KNK: Acid, Uric, Uricase (Colorimetric) (FDA product code)

Follow KNK: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 862.1775
Review panel
Clinical Chemistry
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
1180 in the last 12 months
Median review time
70 daysthe latest 25 decisions
Recall records
151 in the last 12 months
Adverse event reports
5last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code KNK per year, by decision date, 118 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K102568 URIC ACID MODEL 3P39Abbott Laboratories May 6, 2011241 days
K062862 OLYMPUS URIC ACID REAGENT, MODEL OSR6X98Olympus America, Inc. Apr 6, 2007193 days
K040467 VITALAB URIC ACID REAGENTClinical Data, Inc. Mar 8, 200413 days
K031044 ATAC PAK URIC ACID REAGENT AND ATAC CALIBRATORClinical Data, Inc. Jul 15, 2003105 days
K022096 URIC ACID ASSAY FOR THE ADVIA INTEGRATED MODULAR SYSTEMBayer Diagnostics Corp. Mar 18, 2003264 days
K023550 WIENER LAB URICOSTAT ENZIMATICO AA LIQUIDAWiener Laboratories Saic Dec 9, 200248 days
K012038 JAS URIC ACID LIQUID REAGENTJas Diagnostics, Inc. Aug 21, 200153 days
K010421 WIENER LAB. URICOSTAT ENZIMATICO AA, MODELS 2X50 ML CATALOGUE NO 1840106 AND 4X50 ML CATALOGUE NO 1840105Wiener Laboratories Saic Apr 13, 200160 days
K993469 WAKO L-TYPE UA F TESTWako Chemicals USA, Inc. Nov 9, 199927 days
K991247 URIC ACID, MODEL UA112-01A.P. Total Care, Inc. May 25, 199943 days

Recalls

Recall records for product code KNK per year, by the date the recall began. Each recalled product is one record; these 15 records belong to 12 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20181
20191
20200
20210
20220
20230
20240
20250
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-2086-2026Class II DFI Co., Ltd.The devices were distributed without required FDA premarket clearance or approval. Apr 2, 2026
Z-1424-2020Class II Beckman Coulter IncIt has been determined that N-acetyl p benzoquinone imine (NAPQI), a metabolite of acetaminophen (paracetamol), may cause negative interference for assays if p… Aug 15, 2019
Z-0211-2020Class II Beckman Coulter Inc.NAPQI, a metabolite of Acetominophen, causes negative interference with the recalled product assays at levels present in the serum/plasma of overdose patients. Aug 24, 2018
Z-2079-2017Class II Beckman Coulter Inc.Beckman Coulter has identified the following drugs as potential sources of interference: Metamizole (Dipyrone), Sulfasalazine, and Sulfapyridine and may result… Apr 3, 2017
Z-0092-2017Class II Ortho-Clinical DiagnosticsOrtho Clinical Diagnostics confirmed that N-Acetylcysteine (NAC), a drug used for acetaminophen overdose, mucolytic therapy and is used as nutritional suppleme… Aug 11, 2016

Adverse event reports (MAUDE)

Medical device reports received per year that name product code KNK. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20191
20202
20210
20220
20234
20242
20252
2026 (so far)4

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions5
  • Other or not stated0

Most reported device problems, last 12 months

  1. Incorrect Measurement2
  2. Detachment of Device or Device Component1
  3. High Test Results1
  4. Incorrect, Inadequate or Imprecise Result or Readings1
  5. Mechanical Problem1
  6. Temperature Problem1

In plain English: what the newest reports describe Written by AI

  • Several reports describe uric acid results that were questioned because they did not match the patient's condition or earlier results. In these cases the first readings were often much higher than repeat readings, and labs repeated the test, sometimes after replacing the reagent (the chemical mix used in the test) or moving the sample to another analyzer.

    6 reports: 1823260-2026-04289, 1823260-2026-01735, 1823260-2025-03086, 1823260-2024-01803, 1823260-2023-01180, 1823260-2020-03330

  • Several reports describe uric acid reagent packs or cartridges found leaking, cracked, or with loose caps, usually while still at the manufacturer's warehouse or after delivery. In each report no injury or exposure was stated, and the manufacturer replaced the affected product.

    6 reports: 2050012-2011-08480, 2050012-2011-06037, 2050012-2011-02258, 2050012-2011-01965, 2050012-2011-00915, 2050012-2011-00885

  • Two reports describe first results that were high and repeat results that were much lower, with the lower values judged correct in one case. Sample numbers and values were not always clearly tied to specific reports, so the exact cause is not stated.

    2 reports: 1823260-2026-01735, 1823260-2025-03086

  • In one report, a sample gave a high first reading of 120 micromoles per liter, which did not match the patient's previous results. Repeat tests on the same sample gave a reading below the test's lower limit of 12, and the report does not say why the first result differed.

    Report: 1823260-2024-03662

  • In one report, a patient's sample read higher on one module than on another, and the lab suspected an interfering substance (something in the sample that can distort a test) but no cause was confirmed. Results from the same patient gave readings near zero on some runs.

    Report: 1823260-2023-01351

Written by AI from the narratives of the 19 newest reports that have one, received Mar 28, 2011 to Oct 15, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
109in the FDA’s Global Unique Device Identification Database
Establishment listings
70registered establishments that list this product code

Watch KNK in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get KNK every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KNK. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.