Product codes

FDA product code

KMK: Device, Intravascular Catheter Securement (FDA product code)

Follow KMK: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 880.5210
Review panel
General Hospital
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
640 in the last 12 months
Median review time
119 daysthe latest 25 decisions
Recall records
70 in the last 12 months
Adverse event reports
117last 12 months, 2 deaths

510(k) and De Novo decisions

Decisions for product code KMK per year, by decision date, 64 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20191
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K180994 SecurAcath 10F, SecurAcath 12F, SecurAcath 5F, SecurAcath 5F, SecurAcath 6F, SecurAcath 7F/SecurAcath 8FInterrad Medical, Inc. Jul 9, 2019449 days
K981860 A P HARNESSParaworks Enterprise, Ltd. Jun 3, 1999372 days
K963365 MULTI-PURPOSE MEDICAL TUBE HOLDERByrd Medical Devices, Inc. Oct 11, 199645 days
K941098 SECURE-SITEOp-Co Medical Products , Ltd. Aug 9, 1995518 days
K943147 STATLOCK CVVenetec, Inc. Sep 29, 199491 days
K943047 IV START KITSSterile Concepts, Inc. Sep 14, 199479 days
K941940 IMMOBILE STERILE AND IMMOBILE A/C STERILETnt Moborg Intl. , Ltd. Jul 14, 199484 days
K941850 IMMOBILE NON-STERILE AND IMMOBILE A/C NON-STERILETnt Moborg Intl. , Ltd. Jul 14, 199491 days
K935389 CONMED VENI-GARD I.V. DRESSINGConmedcorp Mar 7, 1994119 days
K935252 K-LOK CATHETER SECUREMENT DEVICE MODIFICATIONK-Lok, Inc. Feb 18, 1994134 days

Recalls

Recall records for product code KMK per year, by the date the recall began. Each recalled product is one record; these 7 records belong to 4 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2120-2017Class II Bard Access Systems Inc.StatLockTM IV Premium Catheter Stabilization Device may contain an incorrectly sized retainer clip. Apr 25, 2017
Z-0981-2017Class II Bard Access SystemsBard Access Systems announces a voluntary field action for the StatLock Catheter Stabilization Devices because some single unit pouches have been released with… Dec 9, 2016
Z-0982-2017Class II Bard Access SystemsBard Access Systems announces a voluntary field action for the StatLock Catheter Stabilization Devices because some single unit pouches have been released with… Dec 9, 2016
Z-1618-2013Class II Bard Access SystemsBARD Access Systems is recalling lot JUWJF283 of StatLock CV Plus Stabilization Butterfly Devices due to incorrect pad assembly used during manufacture. The ab… Jun 10, 2013
Z-0627-2007 Merit Medical Systems, IncSterility of some units may be compromised due to damaged packaging. Feb 15, 2007

Adverse event reports (MAUDE)

Medical device reports received per year that name product code KMK. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201745
201840
201910
202014
202133
2022103
2023138
2024104
202575
2026 (so far)107

Last 12 months by event type

  • Deaths2
  • Injuries12
  • Malfunctions103
  • Other or not stated0

Most reported device problems, last 12 months

  1. Misconnection22
  2. Loss of or Failure to Bond17
  3. Detachment of Device or Device Component14
  4. Adverse Event Without Identified Device or Use Problem11
  5. Difficult to Remove9
  6. Product Quality Problem8

In plain English: what the newest reports describe Written by AI

  • Multiple reports say the dressing does not stick well: it peels or lifts at the edges, comes off too soon, fails to hold in the center, or rips. One staff report says the nonsterile version looks different and falls off within two hours. The manufacturer's findings are not stated.

    9 reports: 1417592-2026-53260, 1824619-2026-00051, 1417592-2026-48842, 1417592-2026-49016, 1824619-2026-00091, 1417592-2026-47820, 1824619-2026-00070, 1417592-2026-60606, 1417592-2026-49674

  • Two reports describe skin harm. One says a skin protectant did not work and caused skin injury, and the other says a patient developed contact dermatitis that led to scratching and sores from the chest to the back. The reports give no further details on cause or outcome.

    2 reports: 3006260740-2026-07698, 3006260740-2026-07123

  • During removal, adhesive sometimes stayed on the catheter and had to be pulled off with forceps, which the report says carries a risk of catheter loss and infection. A second report says the dressing and adhesive came apart in separate pieces instead of together.

    2 reports: 2182318-2026-00115, 1824619-2026-00107

  • Two reports describe a patient who was hospitalized with chills, fever and sweating. The reports do not say whether the device was linked to these symptoms, and one notes that blood culture results were still pending.

    2 reports: 3006260740-2026-07934, 3006260740-2026-07125

Written by AI from the narratives of the 20 newest reports that have one, received Sep 10, 2026 to Oct 27, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
765in the FDA’s Global Unique Device Identification Database
Establishment listings
215registered establishments that list this product code

Product codes classified under the same regulation.

Watch KMK in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get KMK every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KMK. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.