Product codes

FDA product code

KHJ: Polymer, Ent Synthetic-Polyamide (Mesh Or Foil Material) (FDA product code)

Follow KHJ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 874.3620
Review panel
Ear, Nose and Throat
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
341 in the last 12 months
Median review time
97 daysthe latest 25 decisions
Recall records
20 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code KHJ per year, by decision date, 34 since 1991. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20241
20250
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
K260266 Tympendi™ (810)Grace Medical, Inc. Aug 18, 2026202 days
K232646 Biodesign Otologic Butterfly Graft (ENT-OTO-BFLY-0.4-0.6, ENT-OTO-BFLY-0.6-0.9)Cook Biotech Incorporated May 24, 2024268 days
K161000 Biodesign Otologic Repair GraftCook Biotech Incorporated May 11, 201630 days
K150594 Biodesign Otologic Repair GraftCook Biotech Incorprated Sep 16, 2015191 days
K132198 ADAPTAIN, ADAPTAIN FASTWRAP, ENVELOCK, BIOWAICeremed , Inc. Sep 12, 201358 days
K121360 BIODESIGN ENT REPAIR GRAFTCook Biotech Incorprated Feb 27, 2013296 days
K122561 ADAPTAIN FASTWRAP, ENVELOCK, GRAFTAINCeremed , Inc. Nov 27, 201297 days
K120220 ADAPTAIN SOLUBLE IMPLANT MATERIALCeremed , Inc. Jun 6, 2012133 days
K103047 CERETENE SOLUBLE IMPLANT MATERIALCeremed , Inc. Jan 5, 201182 days
K080022 GEL-SPONGE ENT, ABSORBABLE GELATIN SPONGE, USPVascular Solutions, Inc. Dec 9, 2008341 days

Recalls

Recall records for product code KHJ per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20241
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0832-2025Class II Cook Biotech, Inc.Incorrect version of IFU was used rather than updated version; and incorrect expiration date was used on two of the products. Nov 22, 2024
Z-0368-2016Class II Merz North America, Inc.The expiration date encoded in the UDI barcode on the label on the product carton and the peelable patient identification label is incorrect. Oct 26, 2015

Adverse event reports (MAUDE)

Medical device reports received per year that name product code KHJ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20184
20192
20201
20211
20223
20231
20240
20251
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. No Apparent Adverse Event1

In plain English: what the newest reports describe Written by AI

  • Four reports describe scar-like tissue (fibrosis), granulomas (inflammatory lumps) or masses forming in the ear after a graft of this material was placed. In one case a surgeon said the tissue wrapped around the ear bones and required reoperation, and the causes were not confirmed.

    4 reports: 1835959-2020-00001, 1835959-2019-00004, 1835959-2021-00001, 1835959-2018-00010

  • Two reports describe a mismatch where the outer box and plastic sleeve of a device kit showed a later expiration date than the implant inside, which was already expired. One report notes that seven other boxes showed an appropriate date, and the manufacturer's response is not described in detail.

    2 reports: 3003668467-2023-00001, 13415382

  • Two reports describe too much material being injected into a vocal cord, possibly making it overfull. In one, the patient developed a reaction and a second surgeon attempted removal at four months, and in the other, the patient had trouble swallowing and a low fever two days later.

    2 reports: 2135225-2018-00001, 2135225-2015-00041

  • One report describes a needle shaft that broke off at the hub during a vocal cord injection, leaving the needle embedded in the patient's neck. Surgery was needed to remove it.

    Report: 3013840437-2025-00121

  • One report describes stiffening of the cricoarytenoid joint, which controls vocal cord movement, after an injection. The reporter could not determine whether the material caused it, though it was possible the material spread backward into the joint.

    Report: 3013840437-2019-00019

Written by AI from the narratives of the 15 newest reports that have one, received Mar 13, 2014 to Sep 4, 2025. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
91in the FDA’s Global Unique Device Identification Database
Establishment listings
40registered establishments that list this product code

Watch KHJ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get KHJ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KHJ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.