JQX: Nephelometer, For Clinical Use (FDA product code)

Follow JQX: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 862.2700
Review panel
Clinical Chemistry
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
140 in the last 12 months
Median review time
34 daysthe latest 14 decisions
Recall records
40 in the last 12 months
Adverse event reports
18last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code JQX per year, by decision date, 14 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K962294 IMMAGE IMMUNOCHEMISTRY SYSTEMBeckman Instruments, Inc. Aug 21, 199668 days
K922273 ARRAY(R) 360Beckman Instruments, Inc. Aug 19, 199297 days
K885263 QMS(TM) - THEOPHYLLINESeradyn, Inc. Mar 28, 198995 days
K851253 TDX ANALYZER W/NEPHELOMETRY CAROUSELAbbott Laboratories Apr 30, 198533 days
K851234 A-JUST TURBIDITY METERAbbott Laboratories Apr 29, 198534 days
K801362 ALBUMIN NEPHELOMETRIC ASSAYJ.T. Baker Chemical Co. Jul 21, 198042 days
K801089 J.T. BAKER NEPHELOMETERJ.T. Baker Chemical Co. May 28, 198020 days
K792045 BIOVATION NEPHELOMETERBiovation, Inc. Oct 30, 197918 days
K790103 NEPHELOMETER, MIC-2000 LASERDynatech Corp. Mar 12, 197955 days
K781554 RAD-291Organon, Inc. Oct 11, 197830 days

Recalls

Recall records for product code JQX per year, by the date the recall began. Each recalled product is one record; these 4 records belong to 4 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0198-2018Class III Becton Dickinson & Co.Potential unexpected movement of robot arm Jun 1, 2017
Z-2195-2010 Beckman Coulter Inc.Beckman Coulter is initiating a recall of IMMAGE Immunochemistry Systems Buffer 1 (BUF1) due to received reports of increased recovery of control and patient s… May 21, 2010
Recall Becton Dickinson & Co.A operator's manual for a diagnostic test kit is incorrect and may cause inaccurate results for bacterial identification and antibiotic susceptibility in patie… Jan 17, 2006
Recall Becton Dickinson & Co.A calibrator for an in vitro diagnostic kit is not standarized correctly and may cause a calibration error when measuring microbiological cultures for turbidit… Dec 1, 2005

Adverse event reports (MAUDE)

Medical device reports received per year that name product code JQX. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20181
20191
202010
202112
202224
202327
202478
202518
2026 (so far)18

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions18
  • Other or not stated0

Most reported device problems, last 12 months

  1. Incorrect, Inadequate or Imprecise Result or Readings17
  2. Mechanical Problem1

In plain English: what the newest reports describe Written by AI

  • Several reports say the lab cleaned or decontaminated the device and in some cases replaced its consumable parts, and that downstream results then improved. In one report, the instrument tubing had been installed incorrectly, and results improved once it was replaced.

    12 reports: 1119779-2026-00634, 1119779-2026-00641, 1119779-2026-00667, 1119779-2026-00185, 1119779-2026-00056, 1119779-2025-05541, 1119779-2025-05435, 1119779-2025-05095, 1119779-2025-05070, 1119779-2025-05052, 1119779-2025-04644, 1119779-2025-03515

  • Several reports say the device became contaminated, and the device is an instrument used in the lab to test samples. Contamination here means unwanted germs were present in the instrument, and this affected results from other tests run on it.

    11 reports: 1119779-2026-00667, 1119779-2026-00634, 1119779-2026-00641, 1119779-2026-01317, 1119779-2026-00604, 1119779-2025-05095, 1119779-2025-04644, 1119779-2025-03515, 1119779-2025-02645, 1119779-2026-00056, 1119779-2025-05541

  • Some reports say that tests run on a separate downstream instrument gave wrong antibiotic resistance or sensitivity results. In one case a drug appeared falsely resistant, meaning the germ seemed able to resist a medicine it could actually be treated with.

    6 reports: 1119779-2026-00634, 1119779-2026-00641, 1119779-2026-00667, 1119779-2025-04644, 1119779-2025-02645, 1119779-2026-01317

  • One report says the contamination came from the pipette tip adapter, which stayed contaminated with a germ called EPI even after cleaning.

    Report: 1119779-2026-01343

  • One report says the user saw an increase in vancomycin-resistant Staphylococcus aureus, a germ that resists a common antibiotic, while using the device. The reports state no health impact or patient harm.

    Report: 1119779-2026-00840

Written by AI from the narratives of the 18 newest reports that have one, received Aug 7, 2025 to Jul 21, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
11in the FDA’s Global Unique Device Identification Database
Establishment listings
15registered establishments that list this product code

Watch JQX in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get JQX every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in JQX. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.