Product codes

FDA product code

JGY: Colorimetric Method, Triglycerides (FDA product code)

Follow JGY: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 862.1705
Review panel
Clinical Chemistry
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
220 in the last 12 months
Median review time
48 daysthe latest 22 decisions
Recall records
20 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code JGY per year, by decision date, 22 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K120664 PICCOLO TRGLYCERIDES-CAPILLARY TEST SYSTEMAbaxis, Inc. Apr 24, 201250 days
K023639 PICCOLO TRIGLYCERIDES TEST SYSTEMAbaxis, Inc. Jan 24, 200386 days
K000586 BIOSCANNER TRIGLYCERIDES TEST STRIPSPolymer Technology Systems, Inc. Jul 3, 2000132 days
K991894 BIOSCANNER TRIGLYCERIDES TEST STRIPSPolymer Technology Systems, Inc. May 24, 2000356 days
K971005 TRIGLYCERIDESDerma Media Lab., Inc. Apr 21, 199733 days
K954187 TRIGLYCERIDES REAGENTSchiapparelli Biosystems, Inc. Oct 23, 199547 days
K941063 DNA TRIGLYCERIDE PROCEDUREData Medical Associates, Inc. Jul 20, 1994134 days
K931116 IL TEST(TM) TRIGLYCERIDEInstrumentation Laboratory CO Mar 28, 1994389 days
K914033 CHOLESTECH LIPID MONITOR SYST, TRIGLYCERIDES TESTCholestech Corp. Sep 27, 199117 days
K905226 TRIGLYCERIDE (GPO) REAGENT, UNIVERSALEnzyme Technology, Inc. Dec 11, 199021 days

Recalls

Recall records for product code JGY per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20252
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1825-2025Class II Mckesson Medical-Surgical Inc. Corporate Officetransit delays of certain cold chain products due to severe thunderstorms which may caused the products to be stored outside the recommended labeled storage co… Apr 24, 2025
Z-1826-2025Class II Mckesson Medical-Surgical Inc. Corporate Officetransit delays of certain cold chain products due to severe thunderstorms which may caused the products to be stored outside the recommended labeled storage co… Apr 24, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code JGY. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20200
20211
20220
20230
20240
20250
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. High Test Results1

In plain English: what the newest reports describe Written by AI

  • Several reports describe triglyceride results that did not match other results or the expected reaction. In one report, a sample read 483 mg/dL at first but 2120 mg/dL when retested after dilution, and the customer noticed the reaction curve looked wrong. Other reports describe results that were too low or did not match the patient's condition.

    4 reports: 2432235-2008-00047, 2432235-2008-00060, 2050012-2011-01892, 2027969-2026-00053

  • One report says a lab switched reagent lots and found discrepant triglyceride results. The older lot 095939 showed no elevated results, while the newer lot 102610 had several samples reading above the rerun point of 6.22 mmol/L. The report does not say whether any patient was affected.

    Report: 2432235-2008-00047

  • One report says the manufacturer was told of erroneously low triglyceride results for an unknown number of patients tested over about a year. Eight patients were identified and asked to return for retesting, but the report says repeat tests had not been done yet. The effect on the other patients is unknown.

    Report: 2050012-2011-01892

  • One report says a home user's meter showed error E1, which the booklet says means the test strips are defective, even though the strips had not reached their expiry date. The user could not reach the manufacturer because calls went to voicemail and no safety contact number was available.

    Report: MW5099467

  • One report says the lancet supplied with the home testing kit caused swollen finger pricks and bleeding after repeated tests. The user needed to prick several fingers and collect a large amount of blood before the meter gave a result.

    Report: MW5099467

Written by AI from the narratives of the 6 newest reports that have one, received Apr 11, 2001 to May 18, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
64in the FDA’s Global Unique Device Identification Database
Establishment listings
37registered establishments that list this product code

Watch JGY in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get JGY every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in JGY. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.