Product codes

FDA product code

JGQ: Turbidimetric, Total Protein (FDA product code)

Follow JGQ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 862.1635
Review panel
Clinical Chemistry
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
130 in the last 12 months
Median review time
50 daysthe latest 13 decisions
Recall records
10 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code JGQ per year, by decision date, 13 since 1978. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K131051 HITACHI S TEST REAGENT CARTRIDGE TOTAL PROTEIN (TP) AND ALBUMIN (ALB)Hitachi Chemical Diagnostics, Inc. Jun 7, 201353 days
K072638 ROCHE/HITACHI URINARY/CSF PROTEIN WITH MODEL(S) CAT #11877801Roche Diagnostics Corp. Oct 19, 200731 days
K071239 TOTAL PROTEIN URINE/CSF GEN.3Roche Diagnostics Sep 14, 2007134 days
K981295 UPROAbbott Laboratories Oct 1, 1998175 days
K981682 UPROAbbott Laboratories Sep 21, 1998131 days
K925794 TRACE MICROPROTEIN REAGENTTrace America, Inc. Mar 29, 1993133 days
K913615 URINARY/CSF PROTEINBoehringer Mannheim Corp. Sep 13, 199131 days
K903914 PARAMAX CEREBROSPINAL FLUID/URINE PROTEIN BLANKBaxter Healthcare Corp Oct 3, 199040 days
K901083 EMDS(TM) CEREBROSPINAL FLUID PROTEIN, #67668/95Em Diagnostic Systems, Inc. Apr 16, 199040 days
K863478 CEREBROSPINAL FLUID PROTEIN TESTPACK, #67668/95Em Diagnostic Systems, Inc. Oct 29, 198650 days

Recalls

Recall records for product code JGQ per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0017-2014Class II Siemens Healthcare Diagnostics, Inc.Siemens has confirmed an increase on absorbance errors when calibrating Dimension Vista Urinary/Cerebrospinal Fluid Protein (U CFP) Flex Reagent Cartridge lot… Dec 19, 2012

Adverse event reports (MAUDE)

Medical device reports received per year that name product code JGQ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20172
20183
20195
20202
20212
20221
20234
202410
20254
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. False Negative Result1

In plain English: what the newest reports describe Written by AI

  • In several reports, the first result did not fit the patient's condition, and repeat tests on the same sample gave different values, often much lower than the first. Some first results had already been reported outside the laboratory.

    7 reports: 1823260-2025-01129, 1823260-2025-02337, 1823260-2024-00179, 1823260-2024-02563, 1823260-2023-01791, 1823260-2023-02405, 1823260-2024-03211

  • In five reports, the same urine sample gave widely different protein results on repeat testing and at different dilutions (diluting the sample with fluid to lower its concentration). Investigators suspected an interfering substance in some of these samples.

    5 reports: 1823260-2025-00190, 1823260-2024-01749, 1823260-2024-01289, 1823260-2024-02388, 1823260-2026-04196

  • Repeat tests on the same cerebrospinal fluid (spinal fluid) or urine samples gave different values on different analyzers or at other laboratories. In these reports, the laboratory selected one value as correct.

    5 reports: 1823260-2025-00115, 1823260-2024-00614, 1823260-2024-01014, 1823260-2024-00395, 1823260-2022-02540

  • In one report, the analyzer's photometer, which measures how much light a sample absorbs, showed high readings. A technician replaced the heat-cut filter and the check then passed. The customer also noted the urine sample looked cloudy even after centrifugation (spinning to separate material).

    Report: 1823260-2023-03382

Written by AI from the narratives of the 20 newest reports that have one, received Aug 25, 2022 to Oct 9, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
11in the FDA’s Global Unique Device Identification Database
Establishment listings
11registered establishments that list this product code

Product codes classified under the same regulation.

Watch JGQ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get JGQ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in JGQ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.