Product codes

FDA product code

JDZ: Mixer, Cement, For Clinical Use (FDA product code)

Follow JDZ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 888.4210
Review panel
Orthopedic
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
130 in the last 12 months
Median review time
62 daysthe latest 13 decisions
Recall records
183 in the last 12 months
Adverse event reports
238last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code JDZ per year, by decision date, 13 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K934253 EXACTECH ALL POLY ACETABULAR CUPExactech, Inc. Apr 29, 1994241 days
K925025 PRISM BONE CEMENT MIXING SYSTEMDepuy, Inc. Jan 5, 1994460 days
K912190 STRYKER HIGH VACUUM BONE CEMENT MIXER/INJECT SYSTStryker Corp. Aug 29, 1991104 days
K892937 REUSABLE BOWL AND SPATULA FOR MIXING BONE CEMENTSDentsply Intl. Jun 22, 198962 days
K861086 ZIMMER VACUUM MIXING SYSTEMZimmer, Inc. Apr 14, 198624 days
K854077 MIX EVAC IIStryker Corp. Jan 31, 1986116 days
K853310 SIMPLEX ENHANCEMENT MIXERHowmedica Corp. Sep 11, 198535 days
K851205 CEMENTRIFUGEBiodynamic Technologies, Inc. Jul 16, 1985112 days
K843219 ZIMMER BONE CEMENT CENTRIFUGATION SYSZimmer, Inc. Nov 29, 1984106 days
K792186 HOWMEDICA MIX-KIT IIHowmedica Corp. Dec 5, 197935 days

Recalls

Recall records for product code JDZ per year, by the date the recall began. Each recalled product is one record; these 18 records belong to 9 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20176
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)3

Latest recalls

Recall and classFirm and reasonBegan
Z-1946-2026Class II Zimmer, Inc.Ten complaints have been received identifying issues at the time of use related to the package seal, including incomplete seals, wrinkles in the seals or peeli… Mar 30, 2026
Z-1997-2026Class III Heraeus Medical GmbH (Dental Division)Based on long-term stability testing, it was determined that in units older than 1.5 years (17 months) the mixing rod may, in rare cases, come loose from its l… Mar 25, 2026
Z-1998-2026Class III Heraeus Medical GmbH (Dental Division)Based on long-term stability testing, it was determined that in units older than 1.5 years (17 months) the mixing rod may, in rare cases, come loose from its l… Mar 25, 2026
Z-1243-2018Class II Stryker Instruments Div. of Stryker CorporationLack of sterility assurance as bioburden levels were found to be higher than internal acceptable rates. Nov 9, 2017
Z-1244-2018Class II Stryker Instruments Div. of Stryker CorporationLack of sterility assurance as bioburden levels were found to be higher than internal acceptable rates. Nov 9, 2017

Adverse event reports (MAUDE)

Medical device reports received per year that name product code JDZ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201721
201822
201933
2020167
202158
202246
202365
202428
202520
2026 (so far)237

Last 12 months by event type

  • Deaths0
  • Injuries4
  • Malfunctions234
  • Other or not stated0

Most reported device problems, last 12 months

  1. Unsealed Device Packaging215
  2. Detachment of Device or Device Component11
  3. Delivered as Unsterile Product3
  4. Device Contaminated During Manufacture or Shipping2
  5. Adverse Event Without Identified Device or Use Problem1
  6. Crack1

In plain English: what the newest reports describe Written by AI

  • Several reports describe problems found in packaging or sealing before use: a hair-like substance inside the sterile package, and products caught in the sealing area. No patient was involved in these reports, and the manufacturer had no further information.

    4 reports: 0001526350-2026-01255, 0001822565-2026-02345, 0001822565-2026-01568, 0001822565-2026-01532

  • One report describes a cement gun kit cracked at its base. In one, the first kit was replaced, and the second was used with tape placed over the crack. The user was willing to get replacements.

    Report: 51203988

  • In a report, the green rod of the cement mixing unit came loose from the nozzle even though the handle was clicked twice. The surgeon did not notice the cement was not fully mixed, and it was implanted, which required a longer implant during the same surgery.

    Report: 3006406161-2026-00914

  • In a report, the mixer blade came off the mixer lid at the start of the process and then would not turn properly. The cement was not mixed correctly and hardened within about 3 minutes, and the injectors clogged. The surgeon ended the procedure. No physical injury was reported.

    Report: 3003854593-2026-00001

  • In a report, cement leaked outside the bone during use of a gun kit, and the patient was taken to the emergency room with a pulmonary embolism, a blood clot in the lungs. The report does not say whether the leak caused the clot.

    Report: 3003854593-2026-00002

Written by AI from the narratives of the 10 newest reports that have one, received May 12, 2026 to Oct 26, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
271in the FDA’s Global Unique Device Identification Database
Establishment listings
162registered establishments that list this product code

Watch JDZ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get JDZ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in JDZ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.