Product codes

FDA product code

JDX: Instrument, Surgical, Sonic And Accessory/Attachment (FDA product code)

Follow JDX: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 888.4580
Review panel
Orthopedic
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
230 in the last 12 months
Median review time
90 daysthe latest 23 decisions
Recall records
20 in the last 12 months
Adverse event reports
6last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code JDX per year, by decision date, 23 since 1980. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20181
20190
20200
20211
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K201274 Ultrasonic Osteotomy Surgical SystemSmtp Technology Co., Ltd. Feb 19, 2021283 days
K172464 XD880A Ultrasonic Osteotomy Surgical SystemMorley Research Consortium Apr 24, 2018253 days
K163610 PIEZOTOME M+, PIEZOTOME M+ HandpieceSatalec-Acteon Group May 19, 2017148 days
K153743 PIEZOSURGERY PLUSMectron S.P.A. May 25, 2016149 days
K132848 PIEZOSURGERY FLEXMectron S.P.A. Nov 29, 201379 days
K100410 PIEZOELECTRIC SYSTEMSatelec Apr 28, 201071 days
K093805 OSCAR 3Orthosonics, Ltd. Feb 19, 201070 days
K083284 PIEZOSURGERY MEDICALPiezosurgery S.R.L. Apr 8, 2009152 days
K083830 OSCAR BONE RESECTOROrthosonics, Ltd. Mar 20, 200987 days
K072961 LOTUS ULTRASONIC SYSTEM FOR CEMENTED IMPLANT EXTRACTION (USCIX)Sra Developments, Ltd. Dec 19, 200761 days

Recalls

Recall records for product code JDX per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20192
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1962-2019Class II Zimmer Biomet, Inc.The products do not have sufficient data to support the labeled shelf life of 10 years. Jun 4, 2019
Z-1963-2019Class II Zimmer Biomet, Inc.The products do not have sufficient data to support the labeled shelf life of 10 years. Jun 4, 2019

Adverse event reports (MAUDE)

Medical device reports received per year that name product code JDX. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20178
201842
201934
202011
20217
202210
20235
20246
20259
2026 (so far)6

Last 12 months by event type

  • Deaths0
  • Injuries2
  • Malfunctions3
  • Other or not stated1

Most reported device problems, last 12 months

  1. Electrical /Electronic Property Problem4
  2. Improper or Incorrect Procedure or Method2
  3. No Audible Alarm1

In plain English: what the newest reports describe Written by AI

  • Handpieces, the powered tools used to remove bone cement, sometimes stopped working or failed to connect to the generator, the power unit, during surgery. Surgeons in these reports often finished with manual tools, and reported delays ranged from about 30 minutes to 5 hours.

    10 reports: 9680825-2026-00034, 9680825-2026-00014, 9680825-2025-00043, 9680825-2025-00041, 9680825-2025-00010, 9680825-2025-00002, 9680825-2025-00006, 9680825-2024-00045, 9680825-2024-00011, 9680825-2024-00003

  • In three reports, a probe or scraper tip snapped off during use and stayed in the patient. In one, the broken end went into the femur and could not be retrieved, and in another a scraper head fell into the bone's central cavity.

    3 reports: 9680825-2024-00032, 9680825-2025-00013, 9680825-2025-00015

  • Two reports describe two superficial thigh burns during a LEEP procedure, a cervical tissue removal using electrical current. The reports say the wrong grounding pad, the plate that completes the electrical circuit, was used and the electrosurgical unit gave no alarm or stop.

    2 reports: 0001825034-2026-02994, MW6000660

  • Two reports describe piezotome tips, the thin ultrasonic bone-cutting ends, breaking. One says a tip repeatedly broke while entering the nasal cavity and then broke off during use, and the other says a reusable tip broke off the handpiece while being removed with a wrench.

    2 reports: 20609450, 22318042

  • One report describes a generator malfunction during surgery in which the femur cortex, the hard outer layer of the thigh bone, was penetrated. No other details were provided.

    Report: 9680825-2026-00013

Written by AI from the narratives of the 19 newest reports that have one, received Jan 29, 2024 to Oct 8, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
504in the FDA’s Global Unique Device Identification Database
Establishment listings
55registered establishments that list this product code

Product codes classified under the same regulation.

Watch JDX in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get JDX every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in JDX. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.