Product codes

FDA product code

JBP: Activated Whole Blood Clotting Time (FDA product code)

Follow JBP: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 864.7140
Review panel
Hematology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
240 in the last 12 months
Median review time
102 daysthe latest 24 decisions
Recall records
100 in the last 12 months
Adverse event reports
44last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code JBP per year, by decision date, 24 since 1979. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20231
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K223635 Sonoclot Coagulation & Platelet Function Analyzer System with Sonoclot ViewerSienco, Inc. Jan 4, 202330 days
K062604 RAPIDTEG TEG-ACT TESTHaemoscope Corp. Jan 31, 2007152 days
K032952 AIACT KITSienco, Inc. Dec 12, 200381 days
K023582 I-STAT KAOLIN ACT TESTI-Stat Corporation Sep 8, 2003319 days
K020914 ACTALYKE XL ACTIVATED CLOTTING TIME ANALYZER, MODEL 5770Helena Laboratories May 23, 200263 days
K013078 ACTALYKE MINI ACTIVATED CLOTTING TIME TEST SYSTEM, MODEL 5750/5752Helena Laboratories Jan 10, 2002118 days
K002528 SONOCLOT COAGULATION & PLATELET FUNCTION ANALYZER SYSTEM WITH SIGNATURE VIEWER OPTIONSienco, Inc. Aug 31, 200015 days
K994194 (TAS) LOW RANGE HEPARIN MANAGEMENT CARD RAPIDPOINTCardiovascular Diagnostics, Inc. Mar 28, 2000106 days
K992571 I-STAT SYSTEMI-Stat Corp. Feb 10, 2000192 days
K992851 ACT TEST CATRIDGES FOR COAGUCHEK PRO SYSTEM, ACT CONTROLS FOR COAGUCHEK PRO SYSTEMRoche Diagnostics Corp. Jan 14, 2000143 days

Recalls

Recall records for product code JBP per year, by the date the recall began. Each recalled product is one record; these 10 records belong to 8 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20252
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0880-2026Class II Accriva Diagnostics, Inc.Test cuvettes, used with an assay for monitoring heparin anticoagulation, may have a foreign object that has sharp edges and could pose a risk of injury if not… Nov 5, 2025
Z-0539-2026Class II Medtronic Perfusion SystemsMedtronic personnel observed trace amounts of dry blood on the external carton label and Instructions for Use (IFU) in five boxes of one lot of ACT Cartridges. Oct 20, 2025
Z-1341-2011 Abbott Point Of Care Inc.Celite ACT cartridges have increased numbers of values outside the accepted allowable error. Dec 3, 2010
Z-0399-2011 Abbott Point Of Care Inc.Certain lots of i-STAT Celite ACT and Kaolin ACT cartridges may be difficult to fill or will not fill when attempting to transfer blood to the sample entry por… Oct 6, 2010
Z-0400-2011 Abbott Point Of Care Inc.Certain lots of i-STAT Celite ACT and Kaolin ACT cartridges may be difficult to fill or will not fill when attempting to transfer blood to the sample entry por… Oct 6, 2010

Adverse event reports (MAUDE)

Medical device reports received per year that name product code JBP. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201716
20181
201915
202010
20219
20227
202316
202423
202518
2026 (so far)42

Last 12 months by event type

  • Deaths0
  • Injuries2
  • Malfunctions42
  • Other or not stated0

Most reported device problems, last 12 months

  1. Incorrect, Inadequate or Imprecise Result or Readings38
  2. Difficult to Open or Close1
  3. Therapeutic or Diagnostic Output Failure1

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
53in the FDA’s Global Unique Device Identification Database
Establishment listings
35registered establishments that list this product code

Watch JBP in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get JBP every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in JBP. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.