Product codes

FDA product code

JAY: Support, Breathing Tube (FDA product code)

Follow JAY: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 868.5280
Review panel
Anesthesiology
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
190 in the last 12 months
Median review time
31 daysthe latest 19 decisions
Recall records
20 in the last 12 months
Adverse event reports
18last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code JAY per year, by decision date, 19 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K944988 CUSTOM MEDICAL SUSPENSION STRAPCustom Medical Specialties, Inc. Jan 27, 1995107 days
K873491 BLOCK, BITE, INTUBATIONB&B Medical Technologies, Inc. Oct 20, 198750 days
K860583 DALE HEAD BAND ANESTHESIA CIRCUIT TUBE HOLDER 1315Dale Medical Products, Inc. Feb 21, 19863 days
K850924 JEE FRAME (VENTILATOR CIRCUIT SUPPORT)Vulcan Laboratories, Inc. Jul 19, 1985136 days
K850309 COMFIT PLUS ENDOTRACHEAL TUBE HOLDER & BITE BLOCKAckrad Laboratories Feb 14, 198520 days
K840844 ENDO-SECUREExidyne, Inc. Mar 16, 198421 days
K834265 TRACH MATETempe Biomedical, Inc. Jan 4, 198427 days
K834089 COMFITAckrad Laboratories Dec 29, 198331 days
K833374 BITE-BLOCKSontek Industries, Inc. Nov 3, 198337 days
K833361 TUBE-TITLESontek Industries, Inc. Nov 3, 198337 days

Recalls

Recall records for product code JAY per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20221
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0223-2023Class II CooperSurgical, Inc.Firm has received 11 complaints involving a loose or detached metal clips, including 3 cases where the metal clip was ingested by the patient, and 3 cases wher… Oct 20, 2022
Recall Instrumentation Industries Incpotential for the flexible tube portion of the assembly to become brittle and break Oct 14, 2005

Adverse event reports (MAUDE)

Medical device reports received per year that name product code JAY. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20172
20181
201926
202025
202117
202211
202311
20245
20258
2026 (so far)18

Last 12 months by event type

  • Deaths0
  • Injuries13
  • Malfunctions5
  • Other or not stated0

Most reported device problems, last 12 months

  1. Detachment of Device or Device Component13
  2. Adverse Event Without Identified Device or Use Problem2
  3. Premature Separation2
  4. Break1
  5. Loss of or Failure to Bond1
  6. Material Integrity Problem1

In plain English: what the newest reports describe Written by AI

  • Multiple reports say the device lifted from patients' cheeks because it did not stick well, leading to unplanned extubation, where the breathing tube slips out. The hospital routinely used DuoDERM, a dressing not covered by the instructions, and thinks it could be an issue.

    4 reports: 1216677-2026-00180, 1216677-2026-00181, 1216677-2026-00182, 1216677-2026-00183

  • Some reports describe the adhesive not holding or separating, causing the breathing tube to come out. In one case, reintubation (reinserting a breathing tube) was needed. One report says a batch of the device had repeated adhesion problems at one hospital.

    4 reports: 1216677-2026-00136, 1216677-2026-00067, 1216677-2026-00021, 1216677-2026-00023

  • Reports describe the adhesive tape separating from its backing or lifting on one side during use. One report describes the tube becoming dislodged before it was re-secured, and another calls it a near miss. No harm was reported in either.

    2 reports: 1216677-2026-00001, 1216677-2026-00030

  • Two reports describe the velcro strap that wraps around the breathing tube stretching out or not holding, so the tube may move. In one, staff replaced the device and no harm was reported.

    2 reports: 1216677-2025-00049, 1216677-2026-00067

  • One report describes the bite block (a plastic piece placed between the teeth) snapping while being removed from the breathing tube, leaving a sharp edge that could scratch mouth tissue. Staff had to disconnect the patient from the ventilator to remove the rest.

    Report: 50461305

Written by AI from the narratives of the 18 newest reports that have one, received Sep 4, 2025 to Oct 23, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
165in the FDA’s Global Unique Device Identification Database
Establishment listings
76registered establishments that list this product code

Watch JAY in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get JAY every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in JAY. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.