FDA product code
INI: Vehicle, Motorized 3-Wheeled (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 890.3800
- Review panel
- Physical Medicine
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 35523 in the last 12 months
- Median review time
- 108 daysthe latest 25 decisions
- Recall records
- 220 in the last 12 months
- Adverse event reports
- 33last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code INI per year, by decision date, 355 since 1982. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 5 |
| 2018 | 3 |
| 2019 | 4 |
| 2020 | 1 |
| 2021 | 5 |
| 2022 | 6 |
| 2023 | 9 |
| 2024 | 8 |
| 2025 | 15 |
| 2026 (so far) | 21 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262213 | Power Mobility Scooter (MA03)Nanjing Mijo Technology Co., Ltd. | Sep 29, 202691 days |
| K262553 | MOBILITY SCOOTER (YQ-401,YQ- 401A,YQ-403,YQ-403A)Zhejiang Kailang Technology Co., Ltd. | Sep 29, 202667 days |
| K261078 | Electric Scooter (FNS01,FNS03)Anhui Jbh Medical Apparatus Co., Ltd. | Sep 24, 2026176 days |
| K261859 | Electric Scooter (FDB08, FDB08A, FDB12)Anhui JBH Medical Apparatus Co., Ltd. | Sep 19, 2026107 days |
| K260176 | Mobility Scooter (W3483, W3483A)Zhejiang Innuovo Rehabilitation Devices Co.,Ltd | Aug 10, 2026201 days |
| K260094 | Mobility Scooter (W3465, W3902 (S50 Carbon))Zhejiang Innuovo Rehabilitation Devices Co.,Ltd | Aug 10, 2026209 days |
| K261232 | IERO Mobility Scooter (IERO-01)Jochu Technology Co., Ltd. | Jul 14, 202690 days |
| K261163 | Mobility Scooter (R200)Yongkang Ruihe Metal Product Co., Ltd. | Jul 7, 202689 days |
| K253257 | Virgo Mobility Scooter (Virgo-D,Virgo-F)Jiangsu Intco Medical Products Co., Ltd. | Jun 8, 2026252 days |
| K253600 | Scooter (YD-03)Yurob Rehabilitation Medical Co., Ltd. | Jun 3, 2026197 days |
Recalls
Recall records for product code INI per year, by the date the recall began. Each recalled product is one record; these 22 records belong to 14 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 1 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1505-2021Class II | Merits Holdings Co. dba Merits Health Products, Inc.Seat baseplate pin has broken in the field. | Apr 1, 2021 |
| Z-1235-2014Class II | Golden Technologies, Inc.Buzzaround XL scooters' front to rear lockup can become unintentionally disengaged due to possible improper fit of the front alignment cup to the rear alignmen… | Jan 21, 2014 |
| Z-0115-2014Class II | S.A.E. AFIKIMBreeze C Scooter, motorized 3-wheeled electric scooter for elderly people, is recalled because it may become unresponsive during operation due to an electrical… | Sep 27, 2013 |
| Z-0774-2012 | Invacare CorporationInvacare Corporation decided to recall the products because the scooter backrest fails unexpectedly due to seat flexing, and this has the potential to result i… | Dec 7, 2011 |
| Z-3211-2011 | Pride Mobility Products CorpContract manufacturer error. Component part(s) (fuses) specifications were not adhered to as outlined in Pride's Engineering drawings. | Jun 22, 2011 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code INI. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 45 |
| 2018 | 51 |
| 2019 | 25 |
| 2020 | 26 |
| 2021 | 41 |
| 2022 | 41 |
| 2023 | 32 |
| 2024 | 31 |
| 2025 | 27 |
| 2026 (so far) | 33 |
Last 12 months by event type
- Deaths0
- Injuries27
- Malfunctions6
- Other or not stated0
Most reported device problems, last 12 months
- Appropriate Device Problem Term/Code Not Available29
- Damaged Thread1
- Device Dislodged or Dislocated1
- Fracture1
In plain English: what the newest reports describe Written by AI
Several reports describe the scooter tipping or throwing the rider on ramps, inclines, steps, sidewalks, or indoors. On one incline the wheels allegedly locked, and on another the wheels spun before catching traction and the scooter went down steps.
5 reports: 2530130-2026-01489, 2530130-2026-01354, 2530130-2026-01294, 2530130-2026-01404, 2530130-2026-01487
Several reports say the scooter tipped over when it hit a bump or went over a curb, including one provider who says the user has tipped over seven times. The reports do not say what the manufacturer found.
4 reports: 2530130-2026-01504, 2530130-2026-01496, 2530130-2026-01503, 2530130-2026-01439
Two reports say the scooter moved in a way the rider could not control, with one saying it sped off on its own and the other saying the rider could not steer it and hit objects. A third report, from a single source, says the power cut out while the rider was going down a ramp.
3 reports: 2530130-2026-01379, 2530130-2026-01495, 2530130-2026-01395
Two reports describe problems with the seat. One says the metal frame can be felt and the seat edge scrapes and pinches the skin, allegedly causing sores and infections. The other says a seat problem allegedly caused a bed sore.
2 reports: 2530130-2026-01475, 2530130-2026-01302
One report says the battery pack caught fire, sparked, and smoked when the user turned on the scooter after charging it overnight and disconnecting it from the charger. The report does not state what the manufacturer found.
Report: 2530130-2026-01371
Written by AI from the narratives of the 19 newest reports that have one, received Jun 15, 2026 to Oct 22, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 525in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 255registered establishments that list this product code
Watch INI in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get INI every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in INI. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:INIRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:INIRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:INI · count decision_dateRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:INIRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:INI · count event_date_initiatedRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:INI · count res_event_numberRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1505-2021" "Z-1235-2014" "Z-0115-2014" "Z-0774-2012" "Z-3211-2011")Retrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:INI AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:INI AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:INI AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:INIRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:INIRetrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:890.3800Retrieved Nov 29, 2026, 5:11 AM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.