Product codes

FDA product code

GWG: Endoscope, Neurological (FDA product code)

Follow GWG: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 882.1480
Review panel
Neurology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
954 in the last 12 months
Median review time
165 daysthe latest 25 decisions
Recall records
221 in the last 12 months
Adverse event reports
16last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code GWG per year, by decision date, 95 since 1992. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20174
20184
20193
20202
20213
20220
20235
20241
20252
2026 (so far)4

Latest decisions

NumberDevice and applicantDecision and review time
K260315 cCeLL - In vivoVPIX Medical, Inc. Oct 16, 2026259 days
K260581 KARL STORZ Flexible Video Neuro-EndoscopeKarl Storz SE & CO. KG Oct 14, 2026236 days
K253602 Precision S 4K SinuscopeStryker Endoscopy Jun 4, 2026198 days
K253679 Hydro Irrigation SystemStryker Instruments May 8, 2026168 days
K243429 HJY VisualNext 3D Endoscopic Vision SystemHjy Smart Medical Device Co., Ltd. May 21, 2025197 days
K250752 AURORA® Surgiscope® System (ASX15/60, ASX15/80)Integra LifeSciences Corporation Apr 9, 202528 days
K233391 cCeLL - In vivoVPIX Medical, Inc. Aug 21, 2024324 days
K223615 Digital ClarusScope System, Digital NeuroPEN SystemClarus Medical, LLC Nov 21, 2023351 days
K232618 Aurora Surgiscope SystemRebound Therapeutics Corporation Oct 27, 202359 days
K230125 Neuroblade SystemClearmind Biomedical Oct 13, 2023269 days

Recalls

Recall records for product code GWG per year, by the date the recall began. Each recalled product is one record; these 22 records belong to 15 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20180
20194
20200
20210
20220
20231
20241
20251
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-1485-2026Class II Aesculap IncThere is the potential for the length of the trocar shaft to be too long. Jan 15, 2026
Z-1295-2025Class II Integra LifeSciences Corp.Possibility for the obturator to break (separate). Feb 6, 2025
Z-2331-2024Class II Integra LifeSciences Corp.Potential sheath damage that could lead to tissue damage and/or track hemorrhage. Jun 7, 2024
Z-2518-2023Class II Aesculap Implant Systems LLCTrocar manufactured with the shaft too long and does not meet manufacturing specifications. As a result, when used with the 30 neuroendoscope, a portion of the… Jul 20, 2023
Z-1530-2020Class II Karl Storz EndoscopyDuring a complaint investigation it was determined that an error was observed within the instruction manual included with some scopes. Specifically, The Quick… Aug 27, 2019

Adverse event reports (MAUDE)

Medical device reports received per year that name product code GWG. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201712
201816
201910
202019
202121
202212
20239
20249
202533
2026 (so far)9

Last 12 months by event type

  • Deaths0
  • Injuries7
  • Malfunctions9
  • Other or not stated0

Most reported device problems, last 12 months

  1. Material Fragmentation3
  2. Erratic or Intermittent Display2
  3. Leak/Splash2
  4. Material Disintegration2
  5. No Display/Image2
  6. Compatibility Problem1

In plain English: what the newest reports describe Written by AI

  • Across many reports, the endoscope image flickered, froze, or went black during surgery, and one report says no image appeared at all, delaying the procedure by over an hour. Reports often linked the problem to cable or camera-port connections, such as a cable signal failure or missing connector pins, and reseating or swapping parts sometimes restored the picture.

    9 reports: 9610617-2026-01613, 9610617-2026-01585, 9610617-2025-02286, 9610617-2025-02250, 2027009-2025-02384, 2027009-2025-01707, 2027009-2025-01817, 2027009-2025-01818, 2027009-2026-00152

  • Reports describe irrigation fluid, the water used to rinse the scope during surgery, leaking into the connector and camera control box. This caused the screen to go black, and staff switched to a different system to finish the case.

    3 reports: 24129812, 2183911-2025-00002, 2183911-2025-00001

  • Instruments jammed, broke, or clogged while inside patients and had to be removed. In one report, a cutting loop tip was lost in a uterus and found by X-ray, delaying surgery about an hour. Another report describes a jammed jaw in an infant's brain surgery that had to be broken to remove it.

    3 reports: 9610617-2026-00579, 2020550-2025-02145, 3005168196-2025-00420

  • One report says metal flakes were visible on the endoscope's surgical image, floating in a brain ventricle. The report does not know whether they came from the endoscope, the instruments used, or another source.

    Report: 2020550-2026-00302

  • The manufacturer issued an urgent field safety notice because the laser etching on the connector of lot 521404 shows the wrong model number, 2230-521 instead of 2233-521. The outer and inner package labels are correct.

    Report: MW5178388

Written by AI from the narratives of the 17 newest reports that have one, received Sep 30, 2025 to Jul 14, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
501in the FDA’s Global Unique Device Identification Database
Establishment listings
264registered establishments that list this product code

Watch GWG in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get GWG every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GWG. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.