Product codes

FDA product code

GDW: Staple, Implantable (FDA product code)

Follow GDW: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 878.4750
Review panel
General and Plastic Surgery
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
2855 in the last 12 months
Median review time
141 daysthe latest 25 decisions
Recall records
2250 in the last 12 months
Adverse event reports
10,321last 12 months, 28 deaths

510(k) and De Novo decisions

Decisions for product code GDW per year, by decision date, 285 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
201713
20187
201912
202010
20219
20227
20234
20242
20253
2026 (so far)4

Latest decisions

NumberDevice and applicantDecision and review time
K263461 Tendon AnchorSmith & Nephew, Inc. Oct 27, 202629 days
K254291 easyEndo™ E-Lite Single Use Powered Endoscopic Staplers; easyEndo™ E-Lite Single Use Powered Endoscopic Staplers with Curved Tip; easyEndo™ E-Lite Single Use CartridgesEzisurg Medical Co., Ltd. Sep 25, 2026268 days
K260196 ETHICON™ Circular Stapler (CDH21mm, CDH25mm, CDH29mm, CDH33mm); ETHICON™ Circular Stapler - XL Sealed (ECS21mm, ECS25mm, ECS29mm, ECS33mm)Ethicon Endo-Surgery, LLC May 11, 2026109 days
K253657 Tri-staple 2.0™ Reloads; Endo GIA™ Reloads with Tri-Staple™ Technology; Endo GIA™ Gray Articulating Reloads; Signia™ Small Diameter ReloadsCovidien (Part of Medtronic) Apr 10, 2026141 days
K252739 ETHICON™ 4000 45mm Compact Stapler (EC3DT45C); ETHICON™ 4000 45mm Standard Stapler (EC3DT45S); ETHICON™ 4000 45mm Long Stapler (EC3DT45L); ETHICON™ 3D 45mm White Reload (ER45W); ETHICON™ 3D 45mm Blue Reload (ER45B); ETHICON™ 3D 45mm Green Reload (ER45G); ETHICON™ 3D 45mm Black Reload (ER45T)Ethicon Endo-Surgery, LLC Dec 17, 2025111 days
K250835 ETHICON 4000 60mm Compact Stapler (EC3D60C); ETHICON 4000 60mm Standard Stapler (EC3D60S); ETHICON 4000 60mm Long Stapler (EC3D60L); ETHICON 3D 60mm White Reload (ER60W); ETHICON 3D 60mm Blue Reload (ER60B); ETHICON 3D 60mm Green Reload (ER60G); ETHICON 3D 60mm Black Reload (ER60T)Ethicon Endo-Surgery, LLC May 14, 202555 days
K243276 ECHELON LINEAR™ Stapler 30mm Stapler (GTX30); ECHELON LINEAR™ Stapler 60mm Stapler (GTX60); ECHELON LINEAR™ Stapler 90mm Stapler (GTX90); ECHELON LINEAR™ Stapler 3D 30mm Blue Reload (GTXR30B); ECHELON LINEAR™ Stapler 3D 30mm Green Reload (GTXR30G); ECHELON LINEAR™ Stapler 3D 60mm Blue Reload (GTXR60B); ECHELON LINEAR™ Stapler 3D 60mm Green Reload (GTXR60G); ECHELON LINEAR™ Stapler 3D 90mm Blue Reload (GTXR90B); ECHELON LINEAR™ Stapler 3D 90mm Green Reload (GTXR90G)Ethicon Endo-Surgery, LLC Feb 25, 2025132 days
K241630 ECHELON 4000 60mm Compact Stapler (EC3D60C); ECHELON 4000 60mm Standard Stapler (EC3D60S); ECHELON 4000 60mm Long Stapler (EC3D60L); ECHELON 3D 60mm White Reload (ER60W); ECHELON 3D 60mm Blue Reload (ER60B); ECHELON 3D 60mm Green Reload (ER60G); ECHELON 3D 60mm Black Reload (ER60T)Ethicon Endo-Surgery, LLC Oct 28, 2024144 days
K242679 Disposable Powered Articulating Endoscopic Linear Cutter Stapler & Reloads (30mm series, 45mm series, 60mm series)Fengh Medical Co., Ltd. Oct 4, 202428 days
K222487 Anika Tissue Tack Fixation SystemAnika Therapeutics, Inc. May 8, 2023264 days

Recalls

Recall records for product code GDW per year, by the date the recall began. Each recalled product is one record; these 225 records belong to 58 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20175
201861
201928
202012
20213
20220
20232
20245
20254
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0485-2026Class II Covidien, LPA manufacturing issue could lead to a malformed cover tube press which can lead to internal components' movement during firing - leading to the potential for u… Sep 25, 2025
Z-0486-2026Class II Covidien, LPA manufacturing issue could lead to a malformed cover tube press which can lead to internal components' movement during firing - leading to the potential for u… Sep 25, 2025
Z-0147-2026Class II Ethicon Endo-Surgery IncThe devices were shipped unsterilized. Sep 11, 2025
Z-1746-2025Class I Ethicon Endo-Surgery IncFirm has received an increase in reports regarding inadvertent instrument lockout during surgical procedures involving the device. If lockout occurs, the devic… Apr 22, 2025
Z-3096-2024Class II Smith & Nephew Inc.Product packaging process may result in an improper or incomplete seal of the outer foil pouch surrounding the inner Tyvek pouch, compromising product sterility Aug 12, 2024

Adverse event reports (MAUDE)

Medical device reports received per year that name product code GDW. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201711,643
201814,914
201916,600
202012,332
202113,015
202213,605
202314,623
202413,280
202512,052
2026 (so far)9,259

Last 12 months by event type

  • Deaths28
  • Injuries1,316
  • Malfunctions8,953
  • Other or not stated24

Most reported device problems, last 12 months

  1. Failure to Fire3,084
  2. Failure to Form Staple1,720
  3. Difficult to Open or Close1,038
  4. Adverse Event Without Identified Device or Use Problem1,010
  5. Misfire949
  6. Break466

In plain English: what the newest reports describe Written by AI

  • Several reports describe leaks where the bowel was joined together, often with stool or infection inside the abdomen, and patients had to be reoperated. One report describes a patient who died after a sigmoid colon resection, with the cause not confirmed. One surgeon noted the cause could have been multifactorial and did not initially suspect the stapler.

    7 reports: 3005075853-2026-08954, 3005075853-2026-08959, 3005075853-2026-08960, 3005075853-2026-08961, 3005075853-2026-08963, 3005075853-2026-08964, 3005075853-2026-08965

  • The stapler failed to fire, or fired only partly, in several reports. In one, the handle could not be squeezed and was replaced. In another, the handle stopped responding after an abnormal cracking sound, and a different manufacturer's device finished the operation. A reload that fired only partway was also reported.

    4 reports: 1219930-2026-06711, 1219930-2026-06684, 2647580-2026-03143, 2647580-2026-03146

  • The stapler's jaws would not open or close properly in several reports. In one, the jaws stayed shut after the cartridge was removed and had to be freed by replacing the handle, shell and adapter. In another, the jaws would not open after the fourth staple, and the surgeon used a different instrument to pry them apart.

    3 reports: 1219930-2026-06687, 2955842-2026-43495, 1219930-2026-06696

  • In one report, a gastrojejunostomy test using blue dye showed leaks at several points along the staple line and at the join. The surgeon oversewn the leaking areas, and the operation ran about 45 minutes longer than expected.

    Report: 1219930-2026-06683

  • In one report, the reload did not connect properly to the handle and was marked as already used. The reload was replaced. The manufacturer's initial check found the cartridge was not seated properly.

    Report: 1219930-2026-06718

Written by AI from the narratives of the 17 newest reports that have one, received Oct 29, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
871in the FDA’s Global Unique Device Identification Database
Establishment listings
811registered establishments that list this product code

Product codes classified under the same regulation.

Watch GDW in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get GDW every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GDW. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.