FDA product code
GDT: Staple, Removable (Skin) (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class I
- Regulation
- 21 CFR 878.4760
- Review panel
- General and Plastic Surgery
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 190 in the last 12 months
- Median review time
- 42 daysthe latest 19 decisions
- Recall records
- 50 in the last 12 months
- Adverse event reports
- 100last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code GDT per year, by decision date, 19 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K963234 | STAPLE REMOVAL KITContinental Medical Laboratories, Inc. | Oct 21, 199663 days |
| K943719 | VISISTAT STAPLERPilling Weck, Inc. | Aug 24, 199423 days |
| K925526 | MANIPLER DISPOSABLE SKIN STAPLERMatsutani Seisakusho Co. , Ltd. | Jun 24, 1993234 days |
| K915430 | SKIN STAPLE REMOVER KITCypress Medical Products, Ltd. | Feb 28, 199288 days |
| K911204 | QUALTEX SKIN STAPLE EXTRACTORDeroyal Industries, Inc. | May 8, 199150 days |
| K910586 | AUTO SUTURE(R) POLYMER SKIN GRAFT STAPLER*United States Surgical, A Division of Tyco Healthc | Mar 7, 199124 days |
| K900486 | APPOSE UNITY STERILE DISPOSABLE SKIN STAPLERDavis & Geck, Inc. | Apr 20, 199078 days |
| K861711 | SKIN STAPLE REMOVER WITH SPONGE STERILE DISPOSABLEBusse Hospital Disposables, Inc. | May 16, 198611 days |
| K851974 | V. MUELLER VITAL SKIN STAPLERAmerican V. Mueller | Jun 11, 198535 days |
| K844838 | SKIN STAT II SKIN STAPLING MEDICAL DEVICEEdward Weck, Inc. | Jan 23, 198542 days |
Recalls
Recall records for product code GDT per year, by the date the recall began. Each recalled product is one record; these 5 records belong to 5 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 1 |
| 2018 | 1 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1193-2018Class II | Teleflex MedicalSome boxes are labeled as Visistat Wide devices, when in fact the contain Visistat Regular devices. The 6 individually packaged units within the boxes are corr… | Feb 15, 2018 |
| Z-2108-2017Class II | Teleflex MedicalSome boxes are labeled as containing Visistat Wide devices, when they in fact they contained Visistat Regular device. | Mar 24, 2017 |
| Z-0764-2017Class II | Teleflex MedicalSterility Deficiency: The packages are not sealed properly and thus the sterility is not assured. | Nov 18, 2016 |
| Z-2703-2015Class II | Customed, IncRecall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile. | Jul 10, 2015 |
| Z-0250-2015Class I | Customed, IncCustomed products are being recalled because of compromised sterility, not limited to potentially damaged packaging. Serious deficiencies in the manufacturing… | Oct 8, 2014 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code GDT. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 657 |
| 2018 | 197 |
| 2019 | 212 |
| 2020 | 232 |
| 2021 | 251 |
| 2022 | 98 |
| 2023 | 72 |
| 2024 | 51 |
| 2025 | 109 |
| 2026 (so far) | 82 |
Last 12 months by event type
- Deaths0
- Injuries6
- Malfunctions94
- Other or not stated0
Most reported device problems, last 12 months
- Mechanics Altered42
- Adverse Event Without Identified Device or Use Problem14
- Firing Problem13
- Loose or Intermittent Connection8
- Detachment of Device or Device Component7
- Mechanical Jam6
In plain English: what the newest reports describe Written by AI
Staple removers were described as flimsy, with a loose joint or pin, prongs that separated, or tips too small. Staff said they were hard to grip and squeeze.
6 reports: 1417592-2026-60211, 1417592-2026-55666, 1417592-2026-52035, 1417592-2026-51135, 1417592-2026-44608, 1417592-2026-44755
Staple removers often did not take out staples. In some cases the remover broke the staple without moving it, the staple slipped, or it bent or turned inward, making removal difficult.
4 reports: 1417592-2026-46127, 1417592-2026-44608, 1417592-2026-44755, 1417592-2026-52035
Staplers jammed or stopped working during surgery, or did not dispense staples correctly. One report said two staplers from the same lot both malfunctioned, and a stapler from a different lot worked.
4 reports: 1417592-2026-61255, 1417592-2026-38971, 1417592-2026-14850, 25716205
Staplers or staples broke or fell apart during use. One report said a stapler broke each time it was tried, one said a stapler fell apart during a veterinary procedure, and one said a staple was broken.
3 reports: 1417592-2026-33946, 9612501-2026-02316, 9612501-2026-01780
Staples or particles came loose from the stapler during use. Reports describe staples falling out before firing so the device could not grip tissue, a staple detaching during firing and being found on X-ray and removed, and green particles falling onto an incision with no injury reported.
3 reports: 9612501-2026-01891, 3005075853-2026-07444, 9612501-2026-02869
Written by AI from the narratives of the 18 newest reports that have one, received Jul 1, 2026 to Oct 20, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 104in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 111registered establishments that list this product code
Other codes under 21 CFR 878.4760
Product codes classified under the same regulation.
Watch GDT in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get GDT every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GDT. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:GDTRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:GDTRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:GDT · count decision_dateRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:GDTRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:GDT · count event_date_initiatedRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:GDT · count res_event_numberRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1193-2018" "Z-2108-2017" "Z-0764-2017" "Z-2703-2015" "Z-0250-2015")Retrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:GDT AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:GDT AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:GDT AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:GDTRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:GDTRetrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:878.4760Retrieved Nov 29, 2026, 8:11 AM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil