Product codes

FDA product code

GDT: Staple, Removable (Skin) (FDA product code)

Follow GDT: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 878.4760
Review panel
General and Plastic Surgery
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
190 in the last 12 months
Median review time
42 daysthe latest 19 decisions
Recall records
50 in the last 12 months
Adverse event reports
100last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code GDT per year, by decision date, 19 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K963234 STAPLE REMOVAL KITContinental Medical Laboratories, Inc. Oct 21, 199663 days
K943719 VISISTAT STAPLERPilling Weck, Inc. Aug 24, 199423 days
K925526 MANIPLER DISPOSABLE SKIN STAPLERMatsutani Seisakusho Co. , Ltd. Jun 24, 1993234 days
K915430 SKIN STAPLE REMOVER KITCypress Medical Products, Ltd. Feb 28, 199288 days
K911204 QUALTEX SKIN STAPLE EXTRACTORDeroyal Industries, Inc. May 8, 199150 days
K910586 AUTO SUTURE(R) POLYMER SKIN GRAFT STAPLER*United States Surgical, A Division of Tyco Healthc Mar 7, 199124 days
K900486 APPOSE UNITY STERILE DISPOSABLE SKIN STAPLERDavis & Geck, Inc. Apr 20, 199078 days
K861711 SKIN STAPLE REMOVER WITH SPONGE STERILE DISPOSABLEBusse Hospital Disposables, Inc. May 16, 198611 days
K851974 V. MUELLER VITAL SKIN STAPLERAmerican V. Mueller Jun 11, 198535 days
K844838 SKIN STAT II SKIN STAPLING MEDICAL DEVICEEdward Weck, Inc. Jan 23, 198542 days

Recalls

Recall records for product code GDT per year, by the date the recall began. Each recalled product is one record; these 5 records belong to 5 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20181
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1193-2018Class II Teleflex MedicalSome boxes are labeled as Visistat Wide devices, when in fact the contain Visistat Regular devices. The 6 individually packaged units within the boxes are corr… Feb 15, 2018
Z-2108-2017Class II Teleflex MedicalSome boxes are labeled as containing Visistat Wide devices, when they in fact they contained Visistat Regular device. Mar 24, 2017
Z-0764-2017Class II Teleflex MedicalSterility Deficiency: The packages are not sealed properly and thus the sterility is not assured. Nov 18, 2016
Z-2703-2015Class II Customed, IncRecall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile. Jul 10, 2015
Z-0250-2015Class I Customed, IncCustomed products are being recalled because of compromised sterility, not limited to potentially damaged packaging. Serious deficiencies in the manufacturing… Oct 8, 2014

Adverse event reports (MAUDE)

Medical device reports received per year that name product code GDT. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017657
2018197
2019212
2020232
2021251
202298
202372
202451
2025109
2026 (so far)82

Last 12 months by event type

  • Deaths0
  • Injuries6
  • Malfunctions94
  • Other or not stated0

Most reported device problems, last 12 months

  1. Mechanics Altered42
  2. Adverse Event Without Identified Device or Use Problem14
  3. Firing Problem13
  4. Loose or Intermittent Connection8
  5. Detachment of Device or Device Component7
  6. Mechanical Jam6

In plain English: what the newest reports describe Written by AI

  • Staple removers were described as flimsy, with a loose joint or pin, prongs that separated, or tips too small. Staff said they were hard to grip and squeeze.

    6 reports: 1417592-2026-60211, 1417592-2026-55666, 1417592-2026-52035, 1417592-2026-51135, 1417592-2026-44608, 1417592-2026-44755

  • Staple removers often did not take out staples. In some cases the remover broke the staple without moving it, the staple slipped, or it bent or turned inward, making removal difficult.

    4 reports: 1417592-2026-46127, 1417592-2026-44608, 1417592-2026-44755, 1417592-2026-52035

  • Staplers jammed or stopped working during surgery, or did not dispense staples correctly. One report said two staplers from the same lot both malfunctioned, and a stapler from a different lot worked.

    4 reports: 1417592-2026-61255, 1417592-2026-38971, 1417592-2026-14850, 25716205

  • Staplers or staples broke or fell apart during use. One report said a stapler broke each time it was tried, one said a stapler fell apart during a veterinary procedure, and one said a staple was broken.

    3 reports: 1417592-2026-33946, 9612501-2026-02316, 9612501-2026-01780

  • Staples or particles came loose from the stapler during use. Reports describe staples falling out before firing so the device could not grip tissue, a staple detaching during firing and being found on X-ray and removed, and green particles falling onto an incision with no injury reported.

    3 reports: 9612501-2026-01891, 3005075853-2026-07444, 9612501-2026-02869

Written by AI from the narratives of the 18 newest reports that have one, received Jul 1, 2026 to Oct 20, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
104in the FDA’s Global Unique Device Identification Database
Establishment listings
111registered establishments that list this product code

Product codes classified under the same regulation.

Watch GDT in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get GDT every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GDT. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.