Product codes

FDA product code

GAQ: Suture, Nonabsorbable, Steel, Monofilament And Multifilament, Sterile (FDA product code)

Follow GAQ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 878.4495
Review panel
General and Plastic Surgery
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
320 in the last 12 months
Median review time
132 daysthe latest 25 decisions
Recall records
82 in the last 12 months

510(k) and De Novo decisions

Decisions for product code GAQ per year, by decision date, 32 since 1987. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20181
20190
20201
20210
20221
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K203855 CoNextions TR Tendon Repair SystemConextions Medical Apr 22, 2022477 days
K193209 Wego-Stainless SteelFoosin Medical Supplies Inc., Ltd. Feb 19, 202090 days
K172146 MERISTEELM/s. Meril Endo Surgery Private Limited. Feb 1, 2018199 days
K170767 Surgical Stainless Steel Suture, Stainless Steel SutureETHICON, Inc. Nov 1, 2017232 days
K141007 DEMESTEEL (STAINLESS STEEL) NON-ABSORBABLE SUTUREDemetech Corp. Sep 25, 2014160 days
K140127 FERROFIBRE STAINLESS STEEL SUTURE WITH CRIMPPontis Orthopaedics, LLC May 28, 2014132 days
K081060 FERROFIBRE STAINLESS STEEL SUTURES, MODEL 610 SERIES SIZES (USP) 5-0 TO #5Core Essence Orthopaedics, LLC Dec 24, 2008254 days
K082828 SUTURTEK 360 DEGREE STERNAL CLOSURE DEVICESuturtek Incorporated Oct 14, 200819 days
K063603 SUTURTEK SURGICAL STEEL SUTURE, MODELS SC-S13, SC-S14, SC-S15, SC-S16, SC-S17Suturtek Incorporated Feb 7, 200766 days
K042606 MODIFICATION TO:SYNTHES (USA) TITANIUM WIRESynthes (Usa) May 27, 2005245 days

Recalls

Recall records for product code GAQ per year, by the date the recall began. Each recalled product is one record; these 8 records belong to 6 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20192
20200
20210
20221
20230
20240
20250
2026 (so far)2

Latest recalls

Recall and classFirm and reasonBegan
Z-0284-2027Class II Ethicon, LLCNylon suture indicated for use in general soft tissue approximation and/or ligation may have needles with distorted curvature, that may break during use, or co… Sep 23, 2026
Z-0153-2027Class II Ethicon, LLCSilk sutures, indicated for use in cardiovascular, ophthalmic and neurological procedures, packaged with alcohol-based fluid, not part of product design, that… Sep 8, 2026
Z-1802-2022Class III Mckesson Medical-Surgical Inc. Corporate OfficeFacility Temperature excursions (from June 2021-August 2021) prior to delivery; exposure to higher temperatures may have impacted product effectiveness. All lo… May 25, 2022
Z-1841-2019Class II Ethicon, Inc.Possibility that a suture raw material containing high endotoxin levels was used in the manufacturing of this lot Apr 19, 2019
Z-1842-2019Class II Ethicon, Inc.Possibility that a suture raw material containing high endotoxin levels was used in the manufacturing of this lot Apr 19, 2019

Adverse event reports (MAUDE)

Medical device reports received per year that name product code GAQ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

This section didn’t load from openFDA. It’s retried within the hour.

Last 12 months by event type

This section didn’t load from openFDA. It’s retried within the hour.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
965in the FDA’s Global Unique Device Identification Database
Establishment listings
108registered establishments that list this product code

Watch GAQ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get GAQ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GAQ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.