Product codes

FDA product code

FTC: Light, Ultraviolet, Dermatological (FDA product code)

Follow FTC: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 878.4630
Review panel
General and Plastic Surgery
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
2744 in the last 12 months
Median review time
90 daysthe latest 25 decisions
Recall records
154 in the last 12 months
Adverse event reports
8last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code FTC per year, by decision date, 274 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20172
20183
20192
20205
20213
20221
20234
20241
20253
2026 (so far)4

Latest decisions

NumberDevice and applicantDecision and review time
K262885 308nm Ultraviolet Light Therapy Device (XWYL-401A, XWYL-403A)Guangxi Hope Medical Devices Technology Co., Ltd. Oct 14, 202658 days
K262285 UV Phototherapy Device (KZX-308nm-BL65, KZX-308nm-BL55, KZX-308nm-BL50, KZX-308nm-BL45, KZX-308nm-BL35)Shijiazhuang Recovery Star Medical Device Co., Ltd. Oct 5, 202691 days
K254234 Phototherapy System (DUV-COMBO)Choyang Medics Co., Ltd. May 1, 2026123 days
K253871 Klär Lite (RCW-KL1000)Radcliffe Watts, LLC Mar 4, 202690 days
K250425 Ultraviolet Phototherapy DeviceAPK Technology Co., Ltd. Apr 7, 202552 days
K244022 308nm UV Phototherapy System (UV-K, UV-X, UV-Y, UV-Z)Boston Aesthetics, Inc. Mar 13, 202576 days
K242977 308nm Excimer Phototherapy Device (CN-308E, KN-4003B3, KN-4003B4, KN-5000C KN-5000D, KN-5000H, KN-5000K)Xuzhou Kernel Medical Equipment Co., Ltd. Feb 6, 2025133 days
K242908 UV Phototherapy Device (Group A: SQ308PCHFD, SQ308PCQFD, SQ308PCPFD, SQ308PCNFD, SQ308PCMFD, Group B: SQ308PHTFF, SQ308PHSFF, SQ308PHRFF, SQ308PHZFG, SQ308PPUFF, SQ308PPVFF, SQ308PPWFG)Shanghai Sigma High-Tech Co., Ltd. Dec 19, 202486 days
K233811 DT Controlled Phototherapy EquipmentDaavlin Distributing Co. Dec 13, 202314 days
K223882 Narrowband UV Phototherapy Light Lamp (Model: HB-UPLL-01, HB-UPLL-02)Shenzhen Honpal Optoelectronic Technology Co., Ltd. Mar 27, 202390 days

Recalls

Recall records for product code FTC per year, by the date the recall began. Each recalled product is one record; these 15 records belong to 8 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20180
20190
20200
20210
20222
20230
20240
20251
2026 (so far)3

Latest recalls

Recall and classFirm and reasonBegan
Z-2742-2026Class II Daavlin Distributing CompanyCalibrated Output was not calculating correctly - UV Sensor GAIN being applied was incorrect - GAIN seemed to be "4/5" instead of "7" (counts were at ~1000 ins… Mar 5, 2026
Z-2743-2026Class II Daavlin Distributing CompanyCalibrated Output was not calculating correctly - UV Sensor GAIN being applied was incorrect - GAIN seemed to be "4/5" instead of "7" (counts were at ~1000 ins… Mar 5, 2026
Z-2744-2026Class II Daavlin Distributing CompanyCalibrated Output was not calculating correctly - UV Sensor GAIN being applied was incorrect - GAIN seemed to be "4/5" instead of "7" (counts were at ~1000 ins… Mar 5, 2026
Z-2295-2026Class II Daavlin Distributing CompanySome of the Calibration/Output Certificates had the outputs reversed. Dec 10, 2025
Z-1073-2022Class II Daavlin Distributing CompanySoftware issue, resuming an interrupted treatment will result in swap of utilized calibration treatment distance 0" inches to "9. Resulting in over or under do… Apr 26, 2022

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FTC. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20172
20180
201914
20204
202148
20224
20235
20244
20258
2026 (so far)6

Last 12 months by event type

  • Deaths0
  • Injuries6
  • Malfunctions2
  • Other or not stated0

Most reported device problems, last 12 months

  1. Patient Device Interaction Problem2
  2. Adverse Event Without Identified Device or Use Problem1
  3. Missing Information1
  4. Off-Label Use1
  5. Use of Device Problem1
  6. Use of Incorrect Control/Treatment Settings1

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
779in the FDA’s Global Unique Device Identification Database
Establishment listings
72registered establishments that list this product code

Product codes classified under the same regulation.

Watch FTC in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FTC every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FTC. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.