Product codes

FDA product code

FOS: Catheter, Umbilical Artery (FDA product code)

Follow FOS: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 880.5200
Review panel
General Hospital
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
340 in the last 12 months
Median review time
151 daysthe latest 25 decisions
Recall records
70 in the last 12 months
Adverse event reports
35last 12 months, 1 death

510(k) and De Novo decisions

Decisions for product code FOS per year, by decision date, 34 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20211
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K201697 Umbilical Vessels CatheterHaolang Medical USA Corporation May 6, 2021318 days
K130725 MODIFIED ARGYLE POLYURETHANE UMBILICAL VESSEL CATHETER 2.5FR, 3.5FR, 5 FR.Covidien Lp, Formerly Registered AS Kendall Apr 17, 201330 days
K120304 FOOTPRINT MEDICAL POLYURETHANE UMBILICAL CATHETERFootprint Medical, Inc. Mar 1, 201229 days
K091213 FOOTPRINT MEDICAL UMBILICAL CATHETER, DUAL LUMENFootprint Medical Sep 25, 2009151 days
K091214 FOOTPRINT MEDICAL SILICONE UMBILICAL CATHETERFootprint Medical Sep 25, 2009151 days
K081515 NEOMED DUAL LUMEN UMBILICAL CATHETER, MODELS S2UVC4.0, S2UVC5.0Neomed, Inc. Jul 21, 200852 days
K073596 NEOMED SINGLE LUMEN UMBILICAL CATHETERNeomed, Inc. Feb 22, 200863 days
K981630 VYGON DOUBLE LUMEN UMBILICAL CATHETERSchiff & Co. Oct 1, 1998147 days
K963972 NEO-CARE DUAL LUMEN UMBILICAL CATHETERKlein-Baker Medical, Inc. Dec 24, 199682 days
K954300 ARGYLE NEO-SERT HYDROPHILIC POLYURETHANE UMBILICAL VESSEL CATHETER INSERTION TRAYSherwood Medical Co. Dec 13, 199590 days

Recalls

Recall records for product code FOS per year, by the date the recall began. Each recalled product is one record; these 7 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20211
20220
20230
20240
20256
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1870-2025Class II Cardinal Health 200, LLCPackaging defect may compromise sterility of the product. Use of a non-sterile product on the patient could lead to infection in neonates. May 2, 2025
Z-1871-2025Class II Cardinal Health 200, LLCPackaging defect may compromise sterility of the product. Use of a non-sterile product on the patient could lead to infection in neonates. May 2, 2025
Z-1872-2025Class II Cardinal Health 200, LLCPackaging defect may compromise sterility of the product. Use of a non-sterile product on the patient could lead to infection in neonates. May 2, 2025
Z-1873-2025Class II Cardinal Health 200, LLCPackaging defect may compromise sterility of the product. Use of a non-sterile product on the patient could lead to infection in neonates. May 2, 2025
Z-1874-2025Class II Cardinal Health 200, LLCPackaging defect may compromise sterility of the product. Use of a non-sterile product on the patient could lead to infection in neonates. May 2, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FOS. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017139
201884
201964
202043
202149
202238
202320
202452
202556
2026 (so far)30

Last 12 months by event type

  • Deaths1
  • Injuries8
  • Malfunctions26
  • Other or not stated0

Most reported device problems, last 12 months

  1. Fluid/Blood Leak9
  2. Break5
  3. Insufficient Device Problem Information5
  4. Connection Problem3
  5. Crack2
  6. Leak/Splash2

In plain English: what the newest reports describe Written by AI

  • The catheter cracked, split, or snapped, sometimes at a marked length such as 15 or 18 cm, or broke off at its branch point. In some cases it broke during removal, and staff had to retrieve the broken piece or remove the line.

    6 reports: 2245270-2026-00088, 2245270-2026-00086, MW5188159, 1718873-2026-00001, 1423537-2026-00197, 1423537-2026-00320

  • Fluid leaked from the line where the tubing joins the hub, or from a spot between the 11 and 12 cm marks. One report also described leaking caused by a crack or hole in the line.

    3 reports: 2245270-2026-00122, 2245270-2026-00075, 1423537-2026-00320

  • Connections sometimes did not hold. One report said a luer tip would not connect, and another said the end would not secure to a stopcock, where a returned sample seemed to be missing part of its lip. A third line came apart from its extension tubing.

    3 reports: 1423537-2026-00321, 1423537-2026-00281, 2245270-2026-00063

  • Three reports describe fluid building up in the abdomen. In one, ultrasound showed the catheter in a shallow spot outside the liver, and in another, about 43 mL of nutrition-like fluid was drained while staff worried the line had gone into tissue.

    3 reports: 2245270-2026-00119, 2245270-2026-00118, 2245270-2026-00099

  • Brain lesions were found by imaging in three newborns who had venous catheters. The reports say an embolic origin, meaning a clot or debris traveling from the catheter, has been considered as one possibility, but this is not confirmed.

    3 reports: 2245270-2026-00106, 2245270-2026-00108, 2245270-2026-00107

Written by AI from the narratives of the 20 newest reports that have one, received Mar 31, 2026 to Oct 20, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
98in the FDA’s Global Unique Device Identification Database
Establishment listings
50registered establishments that list this product code

Watch FOS in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FOS every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FOS. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.