Product codes

FDA product code

FNP: Urinal (FDA product code)

Follow FNP: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 880.6730
Review panel
General Hospital
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
Yes
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
10 in the last 12 months
Median review time
13 daysthe latest 1 decisions
Recall records
00 in the last 12 months
Adverse event reports
2last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code FNP per year, by decision date, 1 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K771738 MALE URINALBemis Health Care Sep 28, 197713 days

Recalls

Recall records for product code FNP per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FNP. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20172
20184
20191
20201
20210
20220
20231
20243
20253
2026 (so far)2

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. Material Frayed1
  2. Sharp Edges1

In plain English: what the newest reports describe Written by AI

  • Several reports describe a patient cutting or scraping the penis on a sharp edge or seam of the urinal, sometimes with bleeding; in some cases the injury was a small skin tear or abrasion, and in others staff could find no break in the skin.

    11 reports: 1417592-2026-01867, 22991314, 19527150, 8935515, 1417592-2018-00074, MW5061418, 18796294, 18796325, 7637324, MW5065224, 1417592-2026-02685

  • Reports describe sharp edges on new plastic urinals, including edges left where parts were broken off the manufacturing mold. One facility noted this on 6 of 8 devices checked.

    3 reports: 9574352, 7243802, 6325507

  • Reports describe urine leaking through a hole at the base of the urinal. One facility said the urinals seemed thinner where the holes were, and the manufacturer said it was sending shipping material. Another report describes a hole in the bottom of the urinal that made it ineffective for any liquid.

    3 reports: 6215528, 22792231, 17548643

  • A report describes fluid leaking from a drainage bag used during surgery, exposing staff to blood and spilling fluid onto the floor. Staff also found the bag hard to position, sometimes needing to lift patients to place it.

    Report: 8043817-2025-00009

  • A report describes a bladder stone catching in the ridges on the inside of the urinal, and staff had to cut the urinal to remove the stone. The report says the urinal has rough edges and many ridges.

    Report: 6236588

Written by AI from the narratives of the 20 newest reports that have one, received Mar 29, 2016 to Jun 19, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
65in the FDA’s Global Unique Device Identification Database
Establishment listings
104registered establishments that list this product code

Product codes classified under the same regulation.

Watch FNP in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FNP every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FNP. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.