FDA product code
FMP: Protector, Skin Pressure (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class I
- Regulation
- 21 CFR 880.6450
- Review panel
- General Hospital
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- Yes
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 230 in the last 12 months
- Median review time
- 30 daysthe latest 23 decisions
- Recall records
- 40 in the last 12 months
- Adverse event reports
- 40last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code FMP per year, by decision date, 23 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K150243 | Invictus Medical GelShieldInvictus Medical, Inc. | May 1, 201588 days |
| K951325 | COMFEEL PLUS PRESSURE RELIEF DRESSINGRichard Hamer Assoc., Inc. | Jul 31, 1995130 days |
| K934731 | MEDSURG STERILE IMAGING PRODUCTSMedsurg Industries, Inc. | Mar 28, 1994180 days |
| K820584 | DECUBICARE PADS & ACCESSORIESAbco Dealers, Inc. | Mar 25, 198221 days |
| K812344 | HEEL OR ELBOW PROTECTORFred Sammons, Inc. | Sep 11, 198124 days |
| K811184 | SPENCO DERMAL PADSSpenco Medical Corp. | May 20, 198121 days |
| K802829 | SCANLAN VASCU-STATTScanlan Intl., Inc. | Jan 15, 198166 days |
| K802185 | ARTERIAL BLOOD SAMPLING KITCurrent Technologies, Inc. | Oct 10, 198030 days |
| K801694 | FLOTATION PAD FOR OPERATING TABLEAction Products, Inc. | Aug 27, 198035 days |
| K801195 | DERMALEX OR NATRAWOOL SKIN PRESSURE PROTStock Wild & Co. | Jun 9, 198024 days |
Recalls
Recall records for product code FMP per year, by the date the recall began. Each recalled product is one record; these 4 records belong to 4 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 1 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-2640-2020Class II | EHOB, Inc.QC inspection observed that a portion of the lot may have been contaminated with blood. | Jun 9, 2020 |
| Z-0601-2016Class II | 3M Company - Health Care BusinessProduct mislabeled as latex free. Actual Catalog number 1581, lot 2020-10AN. contains latex. This could pose a health risk to users with sensitivity or allergi… | Dec 1, 2015 |
| Z-0206-2015Class I | Philips Medical Systems, Inc.Mold on gel filled Gel-E and Squishon products | Oct 10, 2014 |
| Z-2192-2014Class I | Childrens Medical VenturesThe gel-filled Gel-E Donut and Squishon product line has received a number of complaints about visible mold. The mold detected was determined to be Cladosporiu… | May 28, 2014 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code FMP. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 2 |
| 2018 | 1 |
| 2019 | 5 |
| 2020 | 3 |
| 2021 | 4 |
| 2022 | 60 |
| 2023 | 15 |
| 2024 | 10 |
| 2025 | 35 |
| 2026 (so far) | 13 |
Last 12 months by event type
- Deaths0
- Injuries6
- Malfunctions34
- Other or not stated0
Most reported device problems, last 12 months
- Inadequate or Insufficient Training26
- Inadequacy of Device Shape and/or Size3
- Inadequate Instructions for Healthcare Professional3
- No Apparent Adverse Event3
- Insufficient Device Problem Information2
- Detachment of Device or Device Component1
In plain English: what the newest reports describe Written by AI
Three reports describe heel pressure injuries (skin and tissue damage from sustained pressure) while patients were using heel wedge products. One report describes an injury above the heel, one describes injuries to two patients, and one describes injuries in a related product.
3 reports: 3004824601-2025-00222, 3004824601-2025-00220, 3004824601-2025-00211
Three reports describe support wedges flattening under the patient's weight. Two describe an angled wedge bundle that caused three pressure injuries, one a deep tissue injury to the tailbone area. A third reports a purple wedge flattening, and the reporter estimates this happens for patients over 300 pounds.
3 reports: 3004824601-2025-00218, 3004824601-2025-00217, 3004824601-2026-00011
One report says a customer reported that hospital staff did not use a heel wedge product properly, and that 18 hospital-acquired pressure injuries were observed. The reports do not state the manufacturer's findings.
Report: 3004824601-2025-00194
One report describes a clinician injuring a wrist while trying to pull a wedge tail under a larger patient who had not been rolled onto their side. Later MRI found a hairline fracture near the wrist and a ligament tear, treated with a cast.
Report: 0001419181-2026-00019
One report describes a deep tissue injury, a pressure injury deeper under the skin, in a patient while the device was used as intended. The reporter did not confirm a device malfunction, and the manufacturer has started an investigation.
Report: 3004763499-2026-00004
Written by AI from the narratives of the 15 newest reports that have one, received Dec 17, 2025 to Oct 16, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 2,592in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 393registered establishments that list this product code
Watch FMP in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get FMP every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FMP. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:FMPRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FMPRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FMP · count decision_dateRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:FMPRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FMP · count event_date_initiatedRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FMP · count res_event_numberRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-2640-2020" "Z-0601-2016" "Z-0206-2015" "Z-2192-2014")Retrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FMP AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FMP AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FMP AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:FMPRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:FMPRetrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:880.6450Retrieved Nov 29, 2026, 7:52 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil