FDA product code
FMH: Container, Specimen, Sterile (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class I
- Regulation
- 21 CFR 864.3250
- Review panel
- General Hospital
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 230 in the last 12 months
- Median review time
- 36 daysthe latest 23 decisions
- Recall records
- 213 in the last 12 months
- Adverse event reports
- 112last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code FMH per year, by decision date, 23 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K900983 | TRI-TECH URINE SPECIMEN KITTri-Tech, Inc. | Sep 17, 1990199 days |
| K823763 | VARIOUS-SPECIMEN COLLECTORSCordis Corp. | Jan 19, 198336 days |
| K820180 | CALCULI FILTER CUPOmnimedical | Feb 5, 198214 days |
| K812933 | LANCER SPECIMEN CONTAINERSherwood Medical Co. | Nov 6, 198117 days |
| K802340 | SPECIMEN SETAmerican Pharmaseal Div. Ahsc | Oct 10, 198014 days |
| K802002 | URINE SPECIMEN CONTAINER #'S 1013-1016Pollak (Intl.), Ltd. | Sep 9, 198020 days |
| K800947 | MIDSTREAM COLLECTION KITSage Products, Inc. | May 30, 198038 days |
| K800233 | ABCO MIDSTREAM URINE COLLECTION SETAbco Dealers, Inc. | Feb 26, 198021 days |
| K800309 | SPECIMEN COLLECTION PANSage Products, Inc. | Feb 26, 198014 days |
| K792710 | PARA-PAK CLEAN VIALMeridian Diagnostics, Inc. | Jan 28, 198032 days |
Recalls
Recall records for product code FMH per year, by the date the recall began. Each recalled product is one record; these 21 records belong to 18 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 1 |
| 2019 | 3 |
| 2020 | 1 |
| 2021 | 0 |
| 2022 | 1 |
| 2023 | 3 |
| 2024 | 2 |
| 2025 | 2 |
| 2026 (so far) | 3 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-2031-2026Class II | Medline Industries, LPDuring an internal review, Medline identified higher-than-expected endotoxin levels on a representative Medline neuro sponge product, indicating that in-market… | Mar 19, 2026 |
| Z-1406-2026Class II | Medline Industries, LPMedline has identified issues related to calibration of the equipment used to sterilize and package the devices. All products were exposed to the validated ste… | Jan 7, 2026 |
| Z-2122-2026Class II | Medline Industries, LPMedline has identified issues related to calibration of the equipment used to sterilize and package the devices. All products were exposed to the validated ste… | Jan 7, 2026 |
| Z-1768-2025Class II | Klinika Mdical GmbPotential for microbial contamination. | Apr 4, 2025 |
| Z-1769-2025Class II | Klinika Mdical GmbPotential for microbial contamination. | Apr 4, 2025 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code FMH. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 17 |
| 2018 | 45 |
| 2019 | 81 |
| 2020 | 40 |
| 2021 | 22 |
| 2022 | 20 |
| 2023 | 43 |
| 2024 | 39 |
| 2025 | 75 |
| 2026 (so far) | 106 |
Last 12 months by event type
- Deaths0
- Injuries0
- Malfunctions111
- Other or not stated1
Most reported device problems, last 12 months
- Short Fill47
- Incorrect, Inadequate or Imprecise Result or Readings24
- Device Markings/Labelling Problem10
- Device Contamination with Chemical or Other Material5
- Fluid/Blood Leak4
- Unable to Obtain Readings4
In plain English: what the newest reports describe Written by AI
Foreign matter was found inside containers, including lint, hair and mold. In one report, black mold was found inside a urine cup after a patient had used it, and the manufacturer was told a complaint would be filed.
4 reports: 50896993, 25576624, 1917413-2026-00770, 1917413-2026-00463
Packaging was reported torn or breached, which can compromise sterility (kept free of germs). In one case a surgical drape inside a pack had a hole, and in another a bag tore at the corner so the item it held fell to the floor.
3 reports: 1417592-2026-50824, 1423395-2026-00309, 1423395-2026-00491
During a validation study (a test to confirm the product works as intended), samples were not kept preserved for the full 72 hours stated in the instructions for use. The study noted that one sample was affected in each of three reports.
3 reports: 1917413-2026-00679, 1917413-2026-00683, 1917413-2026-00677
Containers were reported to leak, even after the cup was sealed. One report says a specific lot was leaking, and another says leaking has been an ongoing issue.
2 reports: 1417592-2026-47335, 1417592-2026-35819
Particles or additives in sample tubes caused analyzer (testing machine) faults. One report describes rubber bits from a tube stopper clogging the analyzer probe. Another says an additive may affect the analyzer's measurements and cause a test strip error.
2 reports: 1917413-2026-00527, 1917413-2026-00966
Written by AI from the narratives of the 20 newest reports that have one, received May 26, 2026 to Oct 9, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 797in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 309registered establishments that list this product code
Other codes under 21 CFR 864.3250
Product codes classified under the same regulation.
Watch FMH in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get FMH every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FMH. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:FMHRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FMHRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FMH · count decision_dateRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:FMHRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FMH · count event_date_initiatedRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FMH · count res_event_numberRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-2031-2026" "Z-1406-2026" "Z-2122-2026" "Z-1768-2025" "Z-1769-2025")Retrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FMH AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FMH AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FMH AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:FMHRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:FMHRetrieved Nov 29, 2026, 6:46 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:864.3250Retrieved Nov 28, 2026, 8:46 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil