Product codes

FDA product code

FIP: Subsystem, Water Purification (FDA product code)

Follow FIP: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.5665
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
1170 in the last 12 months
Median review time
132 daysthe latest 25 decisions
Recall records
150 in the last 12 months
Adverse event reports
20last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code FIP per year, by decision date, 117 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20181
20192
20201
20211
20221
20233
20241
20254
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K250471 AquaC UNO HFresenius Medical Care Renal Therapies Group, LLC Nov 14, 2025269 days
K251851 DIASAFEplusUS (F00013010)Fresenius Medical Care Renal Therapies Group, LLC Oct 9, 2025115 days
K252181 AquaAFresenius Medical Care North America Sep 9, 202560 days
K250514 UPT Series Medical RO Water Treatment SystemSpecialty Water Technologies, Inc. Mar 17, 202524 days
K232953 AquaBplus; AquaB LITEFresenius Medical Care Renal Therapies Group, LLC Jun 13, 2024266 days
K223479 AQUAbase nXB.Braun Medical, Inc. Aug 16, 2023271 days
K231410 RenaPure Endotoxin Retentive FilterEvoqua Water Technologies, LLC Jul 19, 202365 days
K223656 AmeriWater MediQA Reverse Osmosis System (MSP3HF)AmeriWater, LLC Feb 13, 202369 days
K213507 AquaAFresenius Medical Care Rental Therapies Group, LLC Jul 27, 2022268 days
K211035 U9000 Plus UltrafilterBaxter Healthcare Corporation Oct 19, 2021195 days

Recalls

Recall records for product code FIP per year, by the date the recall began. Each recalled product is one record; these 15 records belong to 13 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20201
20212
20224
20231
20241
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2141-2024Class II Fresenius Medical Care Holdings, Inc.Concentrate Flow was exceeding the maximum 19.9 bar set point. The standard default set point range is between 4 and 18.Error message (F020104, "concentrate pr… May 16, 2024
Z-1351-2023Class II Outset Medical, Inc.An observed trend of high conductivity dialysate alarms in a hemodialysis system as a result of introducing a software tool into the manufacturing process. Jan 24, 2023
Z-1769-2022Class II Fresenius Medical Care Holdings, Inc.Internal ethemet cables are missing one or both ferrite cores therefore the electromagnetic compatibility of the device is not ensured Jun 21, 2022
Z-1770-2022Class II Fresenius Medical Care Holdings, Inc.Internal ethemet cables are missing one or both ferrite cores therefore the electromagnetic compatibility of the device is not ensured Jun 21, 2022
Z-1463-2022Class II Fresenius Medical Care Holdings, Inc.Internal ethernet cable may be misaligned, the cable jacket (insulation) could become compromised due to high temperature and result in the internal ethernet c… Jun 16, 2022

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FIP. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20176
20183
201913
202012
202135
202257
2023140
2024174
202577
2026 (so far)19

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions20
  • Other or not stated0

Most reported device problems, last 12 months

  1. Fluid/Blood Leak10
  2. Sparking4
  3. Arcing2
  4. Smoking2
  5. Crack1
  6. Electrical /Electronic Property Problem1

In plain English: what the newest reports describe Written by AI

  • Seven reports from the reverse osmosis water treatment system describe burning, arcing or sparking at electrical parts such as wires, switches, contactors and power supplies. Some also describe the machine shutting off or failing to power on. The manufacturer's findings are not stated, and the parts were usually replaced.

    7 reports: 3010850471-2026-00004, 3010850471-2026-00006, 3010850471-2026-00007, 3010850471-2026-00005, 3010850471-2026-00003, 3010850471-2026-00002, 3010850471-2026-00001

  • Fluid leaked from the device, in several reports noted as happening before use or during priming, with the exact spot not stated. None of these reports describe harm to a patient.

    6 reports: 9611369-2026-00107, 9611369-2026-00092, 9611369-2026-00049, 9611369-2025-00207, 9611369-2025-00197, 9611369-2025-00196

  • Two reports describe a dialysis filter cracking or rupturing during treatment and leaking. The blood was returned to the patient by hand and treatment was completed, and no injury was reported.

    2 reports: 9611369-2026-00010, 9611369-2025-00194

  • Two reports describe a leaking filter or a patient feeling unwell during hemodialysis, with low blood pressure readings of 73/46 and 78/52 mmHg. The reports do not say whether the device caused these symptoms.

    2 reports: 9611369-2025-00188, 9611369-2025-00198

  • A filter that removes bacterial toxins (endotoxins) was reported to have deformed, and a test found endotoxin downstream of it. The manufacturer reviewed the filter's records and inspections and found no product issue so far, and its root cause investigation is still underway.

    Report: 3003337893-2026-00001

Written by AI from the narratives of the 20 newest reports that have one, received Nov 13, 2025 to Sep 24, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
898in the FDA’s Global Unique Device Identification Database
Establishment listings
147registered establishments that list this product code

Watch FIP in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FIP every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FIP. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.