Product codes

FDA product code

FGE: Stents, Drains And Dilators For The Biliary Ducts (FDA product code)

Follow FGE: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.5010
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
Yes
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
47810 in the last 12 months
Median review time
202 daysthe latest 25 decisions
Recall records
45312 in the last 12 months
Adverse event reports
1,848last 12 months, 10 deaths

510(k) and De Novo decisions

Decisions for product code FGE per year, by decision date, 478 since 1982. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20179
20187
20192
20204
20211
20226
20236
20246
20257
2026 (so far)8

Latest decisions

NumberDevice and applicantDecision and review time
K254179 Drainage CatheterCanyon Medical, Inc. Sep 18, 2026269 days
K262913 Protégé™ EverFlex™ Self-expanding Peripheral Stent SystemMedtronic, Inc. Sep 17, 202629 days
K260835 ARCHIMEDES Biodegradable Stent (Medium)Q3 Medical USA, LLC (C/O Q3 Medical Devices Ltd.) Jul 27, 2026136 days
K253393 Single-use Balloon Dilatation Catheter (AG-5251-083018 AG-5251-085518 AG-5251-088018 AG-5251-083019 AG-5251-085519 AG-5251-088019 AG-5251-083021 AG-5251-085521 AG-5251-088021 AG-5251-083024 AG-5251-085524 AG-5251-088024 AG-5251-103018 AG-5251-105518 AG-5251-108018 AG-5251-103019 AG-5251-105519 AG-5251-108019 AG-5251-103021 AG-5251-105521 AG-5251-108021 AG-5251-103024 AG-5251-105524 AG-5251-108024 AG-5251-123018 AG-5251-125518 AG-5251-128018 AG-5251-123019 AG-5251-125519 AG-5251-128019Hangzhou AGS MedTech Co., Ltd. Jun 24, 2026267 days
K253832 Dilation Balloon CatheterMirco-Tech (Nanjing) Co., Ltd. Apr 24, 2026144 days
K251658 Endoflux™ Biliary & Pancreatic Stent SetsMedi-Globe GmbH Apr 16, 2026321 days
K253987 BARE Wireguided Balloon Dilation Catheter (1235)GIE Medical Mar 13, 202691 days
K253132 Single use stone retrieval balloonsZhejiang Chuangxiang Medical Technology Co., Ltd. Mar 6, 2026162 days
K251123 Niti-S Biliary Stent; Niti-S Biliary Slim M StentTaewoong Medical Co., Ltd. Dec 29, 2025262 days
K251019 BIOTEQ Drainage Catheter Set: BT-PD1-SERIES-G and BT-PDS-SERIES-GBioteque Corporation Dec 22, 2025264 days

Recalls

Recall records for product code FGE per year, by the date the recall began. Each recalled product is one record; these 453 records belong to 97 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20173
201843
201913
20202
202128
202222
202319
20248
20251
2026 (so far)12

Latest recalls

Recall and classFirm and reasonBegan
Z-0143-2027Class II Boston Scientific CorporationDevice was incorrectly manufactured with a guidewire exit port (referred to in the IFU as the RX port), which is not a design feature associated with this devi… Sep 10, 2026
Z-0158-2027Class II W L Gore & Associates, Inc.The potential for the devices to be mislabeled with the incorrect length. Sep 3, 2026
Z-3216-2026Class II Olympus Corporation of the AmericasPotential for the inflation chart label affixed to the shaft of the device to be incorrect and indicate a balloon diameter of 18, 19, or 20 mm, Aug 19, 2026
Z-2914-2026Class II W L Gore & Associates, Inc.10 mm diameter x 7 cm with transmural drainage holes (VSWVH1006) incorrectly labeled as 10 mm diameter x 10 cm length devices without transmural drainage holes… May 22, 2026
Z-2915-2026Class II W L Gore & Associates, Inc.10 mm diameter x 7 cm with transmural drainage holes (VSWVH1006) incorrectly labeled as 10 mm diameter x 10 cm length devices without transmural drainage holes… May 22, 2026

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FGE. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20171,515
20181,681
20191,896
20202,182
20212,297
20221,749
20231,615
20241,948
20251,945
2026 (so far)1,658

Last 12 months by event type

  • Deaths10
  • Injuries297
  • Malfunctions1,532
  • Other or not stated9

Most reported device problems, last 12 months

  1. Material Rupture352
  2. Adverse Event Without Identified Device or Use Problem268
  3. Break207
  4. Burst Container or Vessel121
  5. Inflation Problem115
  6. Activation Failure95

In plain English: what the newest reports describe Written by AI

  • Several reports describe balloons used to widen narrowed vessels or passages that burst or ruptured, usually during inflation. In most of these, the team withdrew the balloon and finished the procedure with another balloon, and no patient complications were reported.

    6 reports: 2124215-2026-57546, 2124215-2026-56902, 2124215-2026-56567, 2124215-2026-56572, 2124215-2026-56596, 3011050570-2026-01006

  • Several reports describe biliary stents placed in the bile duct to drain blocked bile that later moved out of place or became blocked. One stent migrated into the small bowel and had to be removed surgically, and another migrated and caused a bowel obstruction and a perforation requiring surgery.

    3 reports: 3005099803-2026-04359, 3005099803-2026-04332, 3005099803-2026-04338

  • In several reports, a stent or drain was not released or moved as intended. In one, a biliary stent did not deploy from its delivery device, and in another the wire did not fully detach and the guide catheter came loose and a push catheter broke. The team placed a different device each time.

    2 reports: 3001845648-2026-00438, 3005099803-2026-04355

  • Two reports describe a biliary stent that became blocked, one after a few days and one about a month after placement. The second patient had symptoms of a serious bile duct infection and needed the stent replaced. One report described the stent clogging sooner than normal and being removed, with the patient stable.

    2 reports: 3005099803-2026-04352, 3005099803-2026-04392

  • Two reports describe a drain or catheter whose hub, the connector at the end, came loose. In one, the chest tube had an air leak and was removed by a pulmonologist, and the patient was reported to be stable.

    2 reports: 1820334-2026-01117, 1820334-2026-01130

Written by AI from the narratives of the 19 newest reports that have one, received Oct 26, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
4,882in the FDA’s Global Unique Device Identification Database
Establishment listings
545registered establishments that list this product code

Watch FGE in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FGE every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FGE. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.