Product codes

FDA product code

FFT: Electrode, Ph, Stomach (FDA product code)

Follow FFT: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 876.1400
Review panel
Gastroenterology and Urology
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
490 in the last 12 months
Median review time
151 daysthe latest 25 decisions
Recall records
111 in the last 12 months
Adverse event reports
562last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code FFT per year, by decision date, 49 since 1981. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K102543 BRAVO PH MONITORING SYSTEM AND ACCESSORIESGiven Imaging , Ltd. Dec 1, 201089 days
K013951 SANDHILL SCIENTIFIC PEDIATEC PH PROBESandhill Scientific, Inc. Feb 28, 200290 days
K002028 BRAVO PH MONITORING SYSTEMEndonetics, Inc. Sep 29, 200088 days
K961346 PH ANALYSIS MODULESynectics-Dantec Jan 29, 1997320 days
K950087 LOT 440Medical Instruments Corporation Mic AG Feb 6, 1996392 days
K955018 TRIP NGS & SIGMOID CATHETER PHI SLIDE CALCULATORInstrumentarium Corp. Jan 30, 199689 days
K945069 FLEXILOG 2000Oakfield Instruments, Ltd. Jun 13, 1995242 days
K920849 TRIP CIC CATHETERTonometrics, Inc. Mar 17, 19951,116 days
K934434 CYBERRX MODEL 7200Cybermed Control Systems, Inc. Jan 24, 1995519 days
K925405 ZINETICS COMPOSITE SENSOR PROBE W/INTERNAL REF.Synectics-Dantec Sep 30, 1994704 days

Recalls

Recall records for product code FFT per year, by the date the recall began. Each recalled product is one record; these 11 records belong to 9 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20212
20220
20230
20240
20251
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-3090-2026Class I Given Imaging Ltd.Capsule may fail to attach to the esophagus or detach from the delivery device. Risks include patient aspiration/inhalation, perforation of esophagus, obstruct… Aug 6, 2026
Z-2047-2025Class I Given Imaging Ltd.It has been determined that misapplied adhesive on the Bravo CF capsule delivery device may lead to its malfunction. Specifically, the misapplied adhesive may… Jun 3, 2025
Z-1334-2021Class II Covidien LlcThe capsule may fail to attach to the esophageal mucosa, which in turn may lead to the aspiration of the capsule. In the event of capsule aspiration, immediate… Feb 26, 2021
Z-1335-2021Class II Covidien LlcThe capsule may fail to attach to the esophageal mucosa, which in turn may lead to the aspiration of the capsule. In the event of capsule aspiration, immediate… Feb 26, 2021
Z-1619-2016Class II Covidien LLCPotential of an allergic reaction in a patient with nickel sensitivity. Apr 15, 2016

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FFT. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017896
2018955
2019621
2020770
2021516
2022260
2023259
2024239
2025594
2026 (so far)511

Last 12 months by event type

  • Deaths0
  • Injuries126
  • Malfunctions427
  • Other or not stated9

Most reported device problems, last 12 months

  1. Separation Failure261
  2. Positioning Failure238
  3. Failure to Transmit Record18
  4. Break13
  5. Insufficient Device Problem Information10
  6. Entrapment of Device8

In plain English: what the newest reports describe Written by AI

  • In several reports the capsule did not come off the delivery device, so it was pulled out of the patient still attached. In some of these the physician broke the handle to release it, and in one a second capsule also failed.

    10 reports: 9710107-2026-00511, 9710107-2026-00498, 9710107-2026-00497, 9710107-2026-00492, 9710107-2026-00493, MW6003656, MW6003660, MW6003203, MW6003204, 9710107-2026-00488

  • In several reports the capsule failed to attach to the esophagus and was left loose in the mouth, esophagus or throat above the vocal cords. Forceps or an unidentified device was used to retrieve it.

    5 reports: 9710107-2026-00504, 9710107-2026-00499, 9710107-2026-00500, 9710107-2026-00495, 9710107-2026-00484

  • Two reports say only that the capsule failed to attach to the esophagus, and one of them says a second capsule attached successfully.

    2 reports: MW6003209, 9710107-2026-00482

  • One report says the delivery device handle split in two when the plunger was pushed to release the pin. The user held the lower part back together, the pin deployed, and a limited scope check confirmed placement.

    Report: MW6003314

  • One report describes a 5 mm oozing superficial tear in the lining of the stomach or esophagus seen during the procedure. A clip was placed and there was no bleeding at the end; the report does not say what caused the tear.

    Report: 9710107-2026-00488

Written by AI from the narratives of the 18 newest reports that have one, received Sep 30, 2026 to Oct 28, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
109in the FDA’s Global Unique Device Identification Database
Establishment listings
13registered establishments that list this product code

Watch FFT in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FFT every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FFT. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.