FDA product code
FCS: Light, Catheter, Fiberoptic, Glass, Ureteral (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 876.4020
- Review panel
- Gastroenterology and Urology
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 100 in the last 12 months
- Median review time
- 117 daysthe latest 10 decisions
- Recall records
- 30 in the last 12 months
- Adverse event reports
- 5last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code FCS per year, by decision date, 10 since 1988. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K151243 | STRYKER INFRARED ILLUMINATION SYSTEM (IRIS) [AIM Light Source and IRIS Ureteral Kit]Stryker Endoscopy | Aug 20, 2015101 days |
| K061548 | STRYKER URETERAL ILLUMINATION SYSTEM IVStryker Corp. | Sep 28, 2006115 days |
| K982542 | STRYKER URETERAL ILLUMINATOR SYSTEM IIIStryker Endoscopy | Sep 22, 199863 days |
| K943801 | URIGLOW TRANSILLUMINATING URETERIC STENT MODELRocket of London, Ltd. | Aug 15, 1995377 days |
| K945088 | GABRIEL URETERAL ILLUMINATOR SYSTEM IIGabriel Medical, Inc. | Feb 7, 1995113 days |
| K941506 | URETERAL ILLUMINATORApple Medical Corp. | Oct 5, 1994190 days |
| K940019 | GABRIEL URETERAL ILLUMINATOR SYSTEMGabriel Medical, Inc. | May 2, 1994119 days |
| K923436 | ILLUMINATED URETERAL CATHETERCook Urological, Inc. | Mar 5, 1993235 days |
| K874680 | LASEGUIDE 600A, 600B, 400A, AND 400BLaser Peripherals, LLC | Mar 23, 1988131 days |
| K880071 | SURGI-LIGHT ND:YAG LASER FOR UROLOGICAL USELaserguide | Mar 22, 198871 days |
Recalls
Recall records for product code FCS per year, by the date the recall began. Each recalled product is one record; these 3 records belong to 2 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 1 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1870-2017Class II | Cook Inc.Product may overheat, melt, and burn patient. | Mar 7, 2017 |
| Z-1866-2008 | Stryker EndoscopyKit fibers may not illuminate along entire length, which may result in inadequate visibility of the urethral structures during surgery | May 9, 2008 |
| Z-1867-2008 | Stryker EndoscopyKit fibers may not illuminate along entire length, which may result in inadequate visibility of the urethral structures during surgery | May 9, 2008 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code FCS. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 17 |
| 2018 | 6 |
| 2019 | 4 |
| 2020 | 9 |
| 2021 | 6 |
| 2022 | 19 |
| 2023 | 4 |
| 2024 | 3 |
| 2025 | 3 |
| 2026 (so far) | 4 |
Last 12 months by event type
- Deaths0
- Injuries0
- Malfunctions5
- Other or not stated0
Most reported device problems, last 12 months
- Optical Problem3
- Output Problem2
- Nonstandard Device1
In plain English: what the newest reports describe Written by AI
Several reports say the light-carrying stent or catheter did not fully light up: it lit only partway, lit on only one side, or lit only one of two stents when used with multiple light sources. Some reports say the light did not come on at all. The light is meant to help the surgeon see inside the urinary tract.
5 reports: 0002936485-2026-00416, 0002936485-2026-00286, 0002936485-2026-00137, 0002936485-2025-01011, 0002936485-2024-00346
Several reports describe a piece of the device breaking off, either during use or while the field was being prepared. In some cases staff retrieved the broken piece from inside the patient. One report says the tip broke off before it touched the patient.
3 reports: 0002936485-2025-00782, MW5170714, 0002936485-2024-00133
In one report, the device's light was poor a few minutes into the case, after it had looked fine at first. The staff also had trouble connecting one branch of the connector to the light source, and one branch gave no light.
Report: 0002936485-2025-01011
One report says a glass light instrument malfunctioned during a case while the surgeon was locating the ureters. Staff could not be sure all pieces were recovered because the glass is not visible on X-ray, and other light instruments were not available. The report does not say whether the patient was injured.
Report: 9610617-2023-00289
One report says that months after a robotic procedure with stents, the patient stated a piece remained inside the body. The manufacturer could not confirm whether any broken piece was removed, and no further information was available.
Report: 0002936485-2024-00719
Written by AI from the narratives of the 14 newest reports that have one, received Nov 9, 2022 to Jul 9, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 10in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 24registered establishments that list this product code
Watch FCS in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get FCS every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FCS. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:FCSRetrieved Nov 29, 2026, 6:18 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FCSRetrieved Nov 29, 2026, 7:51 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FCS · count decision_dateRetrieved Nov 29, 2026, 6:18 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:FCSRetrieved Nov 29, 2026, 7:51 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FCS · count event_date_initiatedRetrieved Nov 29, 2026, 6:18 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FCS · count res_event_numberRetrieved Nov 29, 2026, 6:18 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1870-2017" "Z-1866-2008" "Z-1867-2008")Retrieved Nov 29, 2026, 7:51 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FCS AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 7:51 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FCS AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 7:51 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FCS AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 6:18 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:FCSRetrieved Nov 29, 2026, 6:18 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:FCSRetrieved Nov 29, 2026, 6:18 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:876.4020Retrieved Nov 29, 2026, 6:18 AM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil