Product codes

FDA product code

EXB: Collector, Ostomy (FDA product code)

Follow EXB: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 876.5900
Review panel
Gastroenterology and Urology
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
1020 in the last 12 months
Median review time
90 daysthe latest 25 decisions
Recall records
50 in the last 12 months
Adverse event reports
25last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code EXB per year, by decision date, 102 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20181
20190
20200
20210
20220
20230
20240
20251
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K252140 Heylo™ SystemColoplast Corp. Oct 6, 202590 days
K181643 SmartBag (SmartPouch)11 Health Technologies Limited Nov 16, 2018147 days
K140938 OSTOM-I ALERT11 Health and Technologies, LLC Oct 10, 2014182 days
K922730 LAKE OSTOMY CARE SETLake Medical Products, Inc. Dec 30, 1993573 days
K882878 ODOR-END EMERGENCY CLEAN UP POWDERCdc Products Corp. Dec 8, 1988150 days
K881636 CONSEAL COLOSTOMY CONTINENCE SYSTEM (ONE-PIECE)Coloplast A/S Jul 13, 198890 days
K880306 EMERGENCY-CLEAN UP(TM) ECPCdc Products Corp. May 20, 1988116 days
K872294 COMBINATION NITE DRAINAGE UNITArnold Technologies Dec 29, 1987196 days
K873929 'CATCH-IT' OR FECAL CONTAINMENT DEVICEMidwest Medical Co. Dec 3, 198769 days
K871526 ODOR-SAFE(TM)(LIQUID) ODOR-SAFE(TM) POWDERCox Family Laboratories, Inc. Oct 13, 1987176 days

Recalls

Recall records for product code EXB per year, by the date the recall began. Each recalled product is one record; these 5 records belong to 5 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-3174-2011 Coloplast Manufacturing US, LLCOn July 19, 2011 Coloplast became aware of the failure or routine sterility testing for one lot of SenSuera and Assura Post-Op Ostomy Bags. Based on these resu… Jul 27, 2011
Z-0013-2012 Convatec Inc.Post-operative kits 57 mm may contain 70 mm pouches. Jun 22, 2011
Z-1610-2011 Convatec Inc.Natura Durahesive ConvaTec Moldable Technology Post Operative/Surgical System (57mm) units may contain pouches with 45 mm Natura flanges, therefore the pouch,… Feb 1, 2011
Z-1314-2008 ConvaTecMislabeled: The carton label reads "For postsurgical use following a urostomy procedure." It should read "For postsurgical use following a colostomy or ileosto… Mar 7, 2008
Z-1179-2008 ConvaTecMislabeled: The market unit carton label reads 5/8 - 1 inch, and it should read 5/16 - 1 inch. The metric units (8-25mm) on the label are correct. Feb 14, 2008

Adverse event reports (MAUDE)

Medical device reports received per year that name product code EXB. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201720
201836
201934
202022
202142
202236
202311
202413
202521
2026 (so far)24

Last 12 months by event type

  • Deaths0
  • Injuries24
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem10
  2. Leak/Splash7
  3. Patient Device Interaction Problem2
  4. Patient-Device Incompatibility2
  5. Backflow1
  6. Biocompatibility1

In plain English: what the newest reports describe Written by AI

  • Several reports describe skin irritation and sores around the stoma (the opening on the belly) under the barrier, often treated with prescribed creams or powder such as Nystatin or steroid cream. Some users also described itching, redness, or wounds, and in some cases the irritation did not improve with treatment.

    6 reports: 1119193-2026-00054, 1119193-2026-00009, 1119193-2026-00004, 1119193-2026-00013, 1119193-2026-00049, 1119193-2026-00017

  • Several reports describe the barrier (the adhesive wafer that sticks to the skin) not sticking well, so it lifted or leaked. In one report the barrier lifted within about 30 seconds, and in others leakage from the bottom or left side was described.

    4 reports: 1119193-2026-00062, 1119193-2026-00054, 1119193-2026-00011, 1119193-2026-00013

  • Two reports describe a pouch or barrier that was removed and replaced often, with wounds or bleeding around the stoma. One report says the user was hospitalized for wound care after effluent (stool or urine) leaked under the barrier while staff were slow to change a full pouch.

    2 reports: 1119193-2026-00040, 1119193-2026-00062

  • One report describes a urostomy bag that did not open fully, causing mucus to block it and a backfill of urine, which the reporter linked to urinary tract infections. A separate report describes a colostomy pouch that arrived folded and creased, which the reporter said affected how it worked.

    2 reports: 3003814961-2026-00001, MW6002336

  • One report describes a user who stretched a pre-cut pouch that was too small for the stoma, which cut the stoma and required emergency care. The report says the clinic's silver nitrate treatment caused the user to pass out before stitches were placed.

    Report: 1119193-2026-00016

Written by AI from the narratives of the 19 newest reports that have one, received Feb 9, 2026 to Oct 22, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
1,544in the FDA’s Global Unique Device Identification Database
Establishment listings
105registered establishments that list this product code

Watch EXB in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get EXB every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in EXB. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.