FDA product code
EWL: Prosthesis, Laryngeal (Taub) (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 874.3730
- Review panel
- Ear, Nose and Throat
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 400 in the last 12 months
- Median review time
- 122 daysthe latest 25 decisions
- Recall records
- 42 in the last 12 months
- Adverse event reports
- 23last 12 months, 1 death
510(k) and De Novo decisions
Decisions for product code EWL per year, by decision date, 40 since 1980. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 1 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K240763 | FirstFit Surgical KitFreudenberg Medical, LLC | Dec 18, 2024273 days |
| K141380 | PROVOX FREEHANDS FLEXIVOICEAtos Medical AB | Sep 26, 2014122 days |
| K131947 | PROVOX VEGA PUNCTURE SETAtos Medical AB | Oct 18, 2013113 days |
| K092593 | PROVOX ACTIVALVE (SIZE 4.5MM, 6MM, 8MM, 10MM, 12.5MM)Atos Medical AB | Oct 14, 2010416 days |
| K093258 | BLOM-SINGER INDWELLING TEP OCCLUDERHelix Medical, LLC | Mar 3, 2010135 days |
| K090455 | PROVOX VEGA, MODEL 8130-8135Atos Medical AB | Jun 5, 2009102 days |
| K082206 | BLOM-SINGER DUAL VALVE INDWELLING VOICE PROSTHESIS, MODELS DV-1600 SERIES, DV-2000 SERIESHelix Medical, LLC | Sep 4, 200830 days |
| K043138 | PROVOX NID VOICE REHABILITATION SYSTEM, MODEL REF 7101 TO 7134Atos Medical AB | Nov 22, 200410 days |
| K022125 | PROVOX FREEHANDS HME, MODEL 7710Atos Medical AB | Jul 30, 200229 days |
| K991587 | BLOM-SINGER INDWELLING 2000 VOICE PROSTHESISHelix Medical, Inc. | Jun 25, 199949 days |
Recalls
Recall records for product code EWL per year, by the date the recall began. Each recalled product is one record; these 4 records belong to 3 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 2 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-2909-2026Class II | Freudenberg Medical, LLCIncorrect labeling- The labeled box for the Large Esophageal Flange contains a Large Esophageal and Tracheal Flange, and the labeled box for the Large Esophage… | Jun 17, 2026 |
| Z-2910-2026Class II | Freudenberg Medical, LLCIncorrect labeling- The labeled box for the Large Esophageal Flange contains a Large Esophageal and Tracheal Flange, and the labeled box for the Large Esophage… | Jun 17, 2026 |
| Z-0128-2014Class III | Helix Medical LLCInHealth Technologies (IHT) is recalling the Blom-Singer Adjustable Tracheostoma Valve II (ATSV II) because the body component of the device is missing from th… | Oct 1, 2013 |
| Z-2336-2012Class III | Helix Medical LLCHelix Medical LLC is recalling the BLOM-SINGER indwelling TEP Occluder due to an invalid expiration date. | Mar 8, 2012 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code EWL. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 15 |
| 2018 | 0 |
| 2019 | 7 |
| 2020 | 2 |
| 2021 | 7 |
| 2022 | 5 |
| 2023 | 4 |
| 2024 | 8 |
| 2025 | 12 |
| 2026 (so far) | 23 |
Last 12 months by event type
- Deaths1
- Injuries20
- Malfunctions2
- Other or not stated0
Most reported device problems, last 12 months
- Biofilm coating in Device6
- Fluid/Blood Leak4
- Device Fell2
- Fracture2
- Installation-Related Problem2
- Material Separation2
In plain English: what the newest reports describe Written by AI
Fluid leaked around or through the device into the airway, sometimes causing pneumonia and hospital stays. In one report, leakage began right after placement and the device was later presumed swallowed; the patient died, but the manufacturer found no link between the death and the device.
4 reports: 3007501574-2026-00005, 3002806269-2026-00024, 2025182-2026-00002, 3002806269-2026-00017
Devices moved out of place: a device came loose and traveled into the airway and lungs, requiring surgery to remove it. In another case a device stuck partly in the throat wall and had to be retrieved in an operation.
3 reports: 3002806269-2026-00029, 3007501574-2026-00010, 3007501574-2026-00003
A part of the valve broke off or was missing, letting food, fluid and mucus enter the airway. One patient was hospitalized with shortness of breath and extra mucus, and the missing piece, a small plastic flap, was later found deep in the windpipe.
3 reports: 3002806269-2026-00027, 3007501574-2026-00008, 2025182-2026-00001
During removal, the flange at the outer end of the valve tore away, leaving the rest of the valve in the puncture site. The patient swallowed the valve and was then checked by scope and chest X-ray to make sure it had not entered the airway.
2 reports: 3002806269-2026-00026, 3007501574-2026-00007
The throat narrowed, blocking food from passing and leaving one patient unable to speak. Balloon dilation was stopped partway because of the device, and steroid injections gave partial relief, allowing small amounts of liquid, though the patient lost weight.
2 reports: 3002806269-2026-00021, 3007501574-2026-00002
Written by AI from the narratives of the 16 newest reports that have one, received Feb 18, 2026 to Oct 12, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 348in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 23registered establishments that list this product code
Other codes under 21 CFR 874.3730
Product codes classified under the same regulation.
Watch EWL in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get EWL every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in EWL. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:EWLRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:EWLRetrieved Nov 29, 2026, 4:12 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:EWL · count decision_dateRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:EWLRetrieved Nov 29, 2026, 4:12 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:EWL · count event_date_initiatedRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:EWL · count res_event_numberRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-2909-2026" "Z-2910-2026" "Z-0128-2014" "Z-2336-2012")Retrieved Nov 29, 2026, 4:12 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:EWL AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 4:12 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:EWL AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 4:12 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:EWL AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 4:12 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:EWLRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:EWLRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:874.3730Retrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil