EOQ: Bronchoscope (Flexible Or Rigid) (FDA product code)

Follow EOQ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 874.4680
Review panel
Ear, Nose and Throat
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
24411 in the last 12 months
Median review time
166 daysthe latest 25 decisions
Recall records
1604 in the last 12 months
Adverse event reports
10,128last 12 months, 37 deaths

510(k) and De Novo decisions

Decisions for product code EOQ per year, by decision date, 244 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20174
20187
201911
202010
202115
202211
202312
202413
202520
2026 (so far)9

Latest decisions

NumberDevice and applicantDecision and review time
K261637 Single-use Flexible BronchoscopeHunan Vathin Medical Instrument Co., Ltd. Sep 23, 2026128 days
K260309 Ambu® aScope™ 5 Broncho 2.7/1.2; Ambu® aScope™ 5 Broncho 4.2/2.2; Ambu® aScope™ 5 Broncho 4.2/2.2 Sampler SetAmbu A/S Sep 16, 2026229 days
K254026 3.8mm Slim ProVu Video Bronchoscope (090-02-0038U); 5.0mm Regular ProVu Video Bronchoscope (090-02-0050U); 6.0mm Large ProVu Video Bronchoscope (090-02-0060U); ProVu Video Bronchoscope 8 display (040-07-0082U)Flexicare Medical Limited. Sep 2, 2026260 days
K260382 MONARCH™ Platform (MON-000008)Auris Health, Inc. Jul 25, 2026170 days
K254037 LungFlow Airway CatheterFree Flow Medical, Inc. Jul 10, 2026206 days
K253137 FUJIFILM Endoscope Model EB-840S; FUJIFILM Endoscope Model EB-840TFujifilm Corporation Jun 16, 2026264 days
K260565 SmartClip Delivery Catheter (ADR-1715)Elucent Medical May 14, 202684 days
K252341 EVIS EXERA III BRONCHOVIDEOSCOPE (OLYMPUS BF-Q190, OLYMPUS BF-H190 , OLYMPUS BF-1TH190)Olympus Medical Systems Corp. Apr 23, 2026269 days
K260420 LoopView® Single-Use Digital Flexible Bronchoscope (B27-C, B27-CG)MacroLux Medical Technology Co., Ltd. Apr 8, 202658 days
K250863 FUJIFILM Ultrasonic Endoscope EB-710USFujifilm Corporation Dec 12, 2025266 days

Recalls

Recall records for product code EOQ per year, by the date the recall began. Each recalled product is one record; these 160 records belong to 46 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
201830
20193
202010
202120
20226
202342
20247
202527
2026 (so far)3

Latest recalls

Recall and classFirm and reasonBegan
Z-1488-2026Class II Olympus Corporation of the AmericasPotential for rubber fragment detachment during use. Jan 29, 2026
Z-1489-2026Class II Olympus Corporation of the AmericasPotential for rubber fragment detachment during use. Jan 29, 2026
Z-1383-2026Class II Auris Health, IncDevice for bronchoscopic visualization, patient airway access has software issue: if application restarts after patient-side selection, prior to bronchoscope l… Jan 21, 2026
Z-1134-2026Class II Intuitive Surgical, Inc.Due to probe bags that may have a compromised or incomplete sterile pouch seal. Dec 4, 2025
Z-0598-2026Class II Noah Medical CorporationDue to Users not having access to the Instructions for Use/User Manual due to it being password protected. Sep 12, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code EOQ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017337
2018279
2019654
2020515
20211,358
20222,541
20235,064
20246,051
20256,619
2026 (so far)9,186

Last 12 months by event type

  • Deaths37
  • Injuries700
  • Malfunctions9,386
  • Other or not stated5

Most reported device problems, last 12 months

  1. No Display/Image2,168
  2. Erratic or Intermittent Display1,188
  3. Detachment of Device or Device Component1,123
  4. Communication or Transmission Problem1,065
  5. Poor Quality Image682
  6. Corroded657

In plain English: what the newest reports describe Written by AI

  • Several reports describe a black or missing image on the bronchoscope's monitor or screen, sometimes during setup, inspection, or reprocessing. One report says the screen went black mid-procedure and a full system restart was needed, and that an error appeared.

    4 reports: 3021325287-2026-00053, 9610595-2026-87875, 9610595-2026-87890, 9610595-2026-87918

  • Several reports describe damage to the outer plastic cover at the tip of the scope (the distal end cover), including burn marks and chips. The manufacturer's evaluation confirmed the burn in one of these reports.

    4 reports: 9610595-2026-88268, 9610595-2026-88423, 9610595-2026-87864, 9610595-2026-87869

  • Several reports describe problems found at service evaluation, including a bending tube that was rusted and a bending section whose connection was detached and not secured. One report describes a peeled coating on the connecting tube, and another describes insufficient suction.

    4 reports: 9610595-2026-88266, 9610595-2026-88183, 9610595-2026-88244, 9610595-2026-88285

  • Two reports describe image noise on the scope. One report describes dot-shaped noise noticed during preparation for use, and another describes noise found during a service evaluation along with other faults.

    2 reports: 9610595-2026-87862, 9610595-2026-88183

  • One report describes a patient who had bleeding during an Ion lung biopsy, which stopped the procedure. The physician said the patient had stopped the blood thinner Plavix 7 days earlier. Later the patient needed a breathing tube again, had heart strain and fluid in the lungs, and died at home 25 days after the procedure.

    Report: 2955842-2026-43630

Written by AI from the narratives of the 17 newest reports that have one, received Oct 29, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
1,199in the FDA’s Global Unique Device Identification Database
Establishment listings
650registered establishments that list this product code

Watch EOQ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get EOQ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in EOQ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.