Product codes

FDA product code

ELZ: Crown, Preformed (FDA product code)

Follow ELZ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 872.3330
Review panel
Dental
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
90 in the last 12 months
Median review time
52 daysthe latest 9 decisions
Recall records
40 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code ELZ per year, by decision date, 9 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K091362 CERAMIC PEDATRIC PREFORMED CROWNEz-Pedo, Inc. Jun 29, 200952 days
K932759 TEMPOARY POLYCARBONATE CROWNSSouth American Dental Exporting Corp. Jul 22, 1994409 days
K931352 PEDO JACKETS OR PJ'SGeorge M. Wilson, Dds Jul 21, 1993126 days
K913152 WHITER BITER CROWNGeorge M. Wilson, Dds Sep 30, 199175 days
K912686 WHITER BITER CROWNGeorge M. Wilson, Dds Sep 16, 199190 days
K892893 SDI POLYCARBONATE CROWN, SCHEIN'SSvenska Dental Instruments AB Jun 6, 198947 days
K883325 PERFORMED CROWN (STAINLESS STEEL)Whitecap Dental Co. Sep 16, 198842 days
K771128 NEKO CERAMIC CONVENIENCE CROWNSSterndent Corp. Jul 15, 197722 days
K770684 CROWN, ACRYLIC, CORAL BRAND, PREFORMEDParker Laboratories, Inc. Apr 26, 197714 days

Recalls

Recall records for product code ELZ per year, by the date the recall began. Each recalled product is one record; these 4 records belong to 4 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2100-2013Class II 3M Company/3m Espe Dental Products3M ESPE is recalling Unitek Primary Stainless Steel Crowns (First Primary UL4) because these products have been manufactured with the incorrect marginal contou… Aug 5, 2013
Z-0428-2014Class III 3M Company - Health Care Business3M is recalling specific lots of 3M ESPE Unitek Primary Stainless Steel Crowns - Series UR4 contain LL3 crowns which are incorrectly labeled as UR4 crowns. Jun 5, 2013
Z-0463-2011 3M Company / Medical DivisionUnitek Stainless Steel Permanent Crowns with product Codes 902150, 900213, and 900223, is mislabeled. The crown contained within the package is incorrectly lab… Oct 6, 2010
Z-0569-2008 3M Company / Medical DivisionMislabeled: Unitek Stainless Steel Permanent Molar Crowns were placed in packaging which incorrectly identified the product as Unitek Stainless Steel Primary M… Oct 17, 2007

Adverse event reports (MAUDE)

Medical device reports received per year that name product code ELZ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20171
20180
20190
20200
20210
20220
20232
20240
20250
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions0
  • Other or not stated0

Most reported device problems, last 12 months

  1. Loosening of Implant Not Related to Bone-Ingrowth1
  2. Loss of Osseointegration1

In plain English: what the newest reports describe Written by AI

  • Six reports describe zirconia copings, the cap-like base of a crown or bridge, cracking or breaking. Some broke during placement or insertion, and others broke after they were in the patient's mouth, including one about a fracture near the edge of the restoration about 18 months later.

    6 reports: 0001038806-2015-00013, 0001038806-2015-00060, 0001038806-2015-00331, 0001038806-2015-00431, 0001038806-2015-00701, 0001038806-2015-00870

  • Four reports describe patients having allergy-like or inflammatory reactions after dental crowns or temporary restorations were placed. Reported symptoms included rash, hives, swelling, skin peeling, anaphylactic shock needing adrenaline, and a child's fever, chills and inflamed palate. One report says the cause is still being tested, and one notes nickel in the product.

    4 reports: MW1028723, 2110898-2006-00003, MW5010899, 3005174370-2013-00001

  • One report describes a child who breathed in a stainless steel crown that came loose before it was cemented in place. It lodged behind the throat pack and into the airway, and a surgeon removed it under general anesthesia. The child went home the same day.

    Report: 2110898-2008-00006

  • One report describes a child who began having seizures a couple of months after receiving stainless steel primary crowns and a filling. The seizures continued on medication, and the report says they stopped after the crowns were removed. The manufacturer's findings are not stated.

    Report: MW5018633

  • One report describes a stainless steel crown that was said to have a hole in its center surface. The patient later needed a tooth extraction because of decay that was noticed after the crown was placed.

    Report: 3005174370-2017-00044

Written by AI from the narratives of the 20 newest reports that have one, received Jun 16, 2003 to Aug 21, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
3,912in the FDA’s Global Unique Device Identification Database
Establishment listings
136registered establishments that list this product code

Watch ELZ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get ELZ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in ELZ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.