Product codes

FDA product code

ELY: Mercury (FDA product code)

Follow ELY: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 872.3070
Review panel
Dental
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
40 in the last 12 months
Median review time
103 daysthe latest 4 decisions
Recall records
00 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code ELY per year, by decision date, 4 since 1990. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K093587 DENTAL MERCURYDmg USA, Inc. Jan 21, 201063 days
K973548 MERCURY DENTALAleaciones Dentales Zeyco, S.A. DE C.V. Mar 23, 1998186 days
K913814 MODEL #05 ANEROID SPHYGMOMANOMETER KITNational Health-Care Equipment, Inc. Jan 16, 1992143 days
K902388 DENTAL-QUECKSILBER (DENTAL MERCURY)Degussa AG Jun 28, 199029 days

Recalls

Recall records for product code ELY per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code ELY. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20172
20180
20191
20200
20210
20220
20230
20241
20250
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions0
  • Other or not stated0

In plain English: what the newest reports describe Written by AI

  • Several reports describe symptoms that patients linked to mercury dental fillings (amalgam), including fatigue, memory and concentration problems, joint pain, balance problems, dizziness and mental disturbances. The reports do not show that the fillings caused these symptoms.

    6 reports: MW5188255, MW5157282, MW5086904, MW5071803, MW1017731, MW1014467

  • Two reports say symptoms improved after the fillings were removed, and one of them says the patient now has no symptoms. Chelation, a treatment that removes metal from the body, was also used in one of these cases.

    2 reports: MW5188255, MW1017731

  • One report describes a blood mercury test of 14 mcg/dL, described as slightly elevated, which the neurologist did not consider concerning. Another report says a urine mercury level was expected but not high enough to assume it directly causes symptoms, because many other factors can affect symptoms.

    2 reports: MW5086904, MW1017731

  • Reports disagree on whether amalgam is harmful. One reporter says patients were not told what the fillings contained before they were placed, and another reporter could not recall any information from the manufacturer.

    2 reports: MW5071803, MW1014467

  • One report describes allergic reactions and ongoing health problems that the reporter believes came from amalgam fillings placed in childhood. The reporter also mentioned a possible language barrier with the dentist and a later kidney and liver infection. The reporter learned of the link only after reading FDA information.

    Report: MW5157282

Written by AI from the narratives of the 7 newest reports that have one, received Aug 26, 1998 to May 14, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
10in the FDA’s Global Unique Device Identification Database
Establishment listings
9registered establishments that list this product code

Product codes classified under the same regulation.

Watch ELY in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get ELY every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in ELY. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.