Product codes

FDA product code

EKS: File, Pulp Canal, Endodontic (FDA product code)

Follow EKS: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 872.4565
Review panel
Dental
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
310 in the last 12 months
Median review time
73 daysthe latest 25 decisions
Recall records
30 in the last 12 months
Adverse event reports
349last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code EKS per year, by decision date, 31 since 1980. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K062856 TF ROTARY NICKEL TITANIUM FILEOrmco Corp. Dec 13, 200679 days
K004031 NT SWIFT; TI\TEC; GATES GLIDDEN DRILLS; DENTAL POWER ENDODONTIC HAND FILESDental Power, Inc. Mar 28, 200190 days
K971319 NT SERIES ENDODONTIC FILES, MAC SERIES ENDODONTIC FILESTycom Dental May 22, 199742 days
K970649 HERO 642Micro-Mega May 16, 199785 days
K962031 QUANTEC SERIES 2000 ENDODONTIC FILESTycom Dental Jun 4, 199611 days
K953604 SHAPING HEDSTROM N.T.Sybron Dental Specialties, Inc. Sep 28, 199557 days
K935542 NICKEL-TITANIUM K-TYPE FILEUnion Broach, Div. Moyco Industries, Inc. Jan 3, 199448 days
K932529 LIGHTSPEED DENTAL HAND INSTRUMENTLightspeed Endodontics Nov 4, 1993163 days
K933582 PROFILE SERIES 29 FILESTulsa Dental Products, Ltd. Oct 20, 199389 days
K902018 DENTAURUM CERAMIC DEBONDING UNITDentauraum, Inc. Apr 3, 1991335 days

Recalls

Recall records for product code EKS per year, by the date the recall began. Each recalled product is one record; these 3 records belong to 3 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20251
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1114-2025Class II US Endodontics, LLCDue to devices being irradiated above the established specification which my result in package integrity issues. Jan 2, 2025
Z-0765-2013Class II Ormco/SybronendoThe length markings on the Lightspeed LSX files were wrong. Dec 12, 2012
Z-1172-2012 Ormco CorporationA recall was initiated because SybronEndo has confirmed that the K3 Engine File G-Pack has label packaging and file mis-marking error. Aug 1, 2008

Adverse event reports (MAUDE)

Medical device reports received per year that name product code EKS. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201753
2018258
2019468
2020421
2021342
2022291
2023264
2024313
2025330
2026 (so far)308

Last 12 months by event type

  • Deaths0
  • Injuries16
  • Malfunctions332
  • Other or not stated1

Most reported device problems, last 12 months

  1. Break340
  2. Material Separation3
  3. Material Fragmentation2
  4. Material Split, Cut or Torn2
  5. Activation, Positioning or Separation Problem1
  6. Fracture1

In plain English: what the newest reports describe Written by AI

  • Endodontic files, the thin instruments used to clean out root canals, broke during use in many of these reports. In most, the broken piece was not removed and stayed in the tooth.

    16 reports: 8031010-2026-00664, 8031010-2026-00662, 8031010-2026-00663, 8031010-2026-00650, 8031010-2026-00649, 8031010-2026-00646, 8031010-2026-00647, 8031010-2026-00648, 8031010-2026-00641, 8031010-2026-00651, 8031010-2026-00643, 9611053-2026-01249, 9611053-2026-01246, 9611053-2026-01240, 9611053-2026-01239, 2320721-2026-00580

  • In several reports the broken piece was left in the tooth and sealed into the root filling. One report says the patient was advised to seek care at a higher-level hospital to have it removed.

    5 reports: 8031010-2026-00650, 8031010-2026-00646, 8031010-2026-00641, 8031010-2026-00662, 8031010-2026-00663

  • Most reports state that no injury occurred. Several others say the outcome is unknown and further information was requested from the reporter, so the final results are not yet clear.

    3 reports: 8031010-2026-00651, 9611053-2026-01240, 9611053-2026-01239

  • One report says a file broke and could not be retrieved, and an attempt to bypass the separated fragment failed. A senior specialist was consulted and the treatment took longer and needed extra follow-up.

    Report: 8031010-2026-00647

  • One report describes files fracturing in two of three patients, both with molar teeth, and the fragments remained in the treated teeth. The report does not say whether the patients were injured.

    Report: 2320721-2026-00580

Written by AI from the narratives of the 16 newest reports that have one, received Oct 8, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
13,700in the FDA’s Global Unique Device Identification Database
Establishment listings
170registered establishments that list this product code

Watch EKS in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get EKS every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in EKS. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.