FDA product code
DXO: Transducer, Pressure, Catheter Tip (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 870.2870
- Review panel
- Cardiovascular
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 641 in the last 12 months
- Median review time
- 112 daysthe latest 25 decisions
- Recall records
- 100 in the last 12 months
- Adverse event reports
- 246last 12 months, 3 deaths
510(k) and De Novo decisions
Decisions for product code DXO per year, by decision date, 64 since 1979. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 2 |
| 2018 | 1 |
| 2019 | 4 |
| 2020 | 2 |
| 2021 | 0 |
| 2022 | 1 |
| 2023 | 0 |
| 2024 | 1 |
| 2025 | 1 |
| 2026 (so far) | 1 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K251367 | OptoMonitor 3Opsens, Inc. | Jan 16, 2026260 days |
| K241418 | OptoMonitor 3Opsens, Inc. | Feb 12, 2025268 days |
| K233904 | ACIST RXi System (016616); ACIST Navvus II Catheter (016675_Acist Medical Systems, Inc. | Jul 17, 2024219 days |
| K222216 | TruWave Disposable Pressure TransducerEdwards Lifesciences, LLC | Dec 22, 2022150 days |
| K202943 | OptoMonitor 3Opsens, Inc. | Nov 24, 202055 days |
| K193620 | OptoMonitor 3Opsens, Inc. | Jun 18, 2020175 days |
| K193279 | Comet II Pressure GuidewireBoston Scientific Corporation | Dec 23, 201926 days |
| K192340 | OptoMonitorOpsens, Inc. | Dec 12, 2019106 days |
| K190852 | Zurich Pressure Guidewire System Model 100Zurich Medical, Inc. | Aug 14, 2019134 days |
| K183413 | TruWave Disposable Pressure TransducerEdwards Lifeciences, LLC | May 1, 2019142 days |
Recalls
Recall records for product code DXO per year, by the date the recall began. Each recalled product is one record; these 10 records belong to 3 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 8 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1959-2021Class II | Edwards Lifesciences, LLCThere is a potential that the pressure tubing may detach from the blood sampling system | May 26, 2021 |
| Z-1960-2021Class II | Edwards Lifesciences, LLCThere is a potential that the pressure tubing may detach from the blood sampling system | May 26, 2021 |
| Z-1961-2021Class II | Edwards Lifesciences, LLCThere is a potential that the pressure tubing may detach from the blood sampling system | May 26, 2021 |
| Z-1962-2021Class II | Edwards Lifesciences, LLCThere is a potential that the pressure tubing may detach from the blood sampling system | May 26, 2021 |
| Z-1963-2021Class II | Edwards Lifesciences, LLCThere is a potential that the pressure tubing may detach from the blood sampling system | May 26, 2021 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code DXO. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 186 |
| 2018 | 179 |
| 2019 | 153 |
| 2020 | 158 |
| 2021 | 116 |
| 2022 | 144 |
| 2023 | 194 |
| 2024 | 197 |
| 2025 | 183 |
| 2026 (so far) | 218 |
Last 12 months by event type
- Deaths3
- Injuries27
- Malfunctions214
- Other or not stated2
Most reported device problems, last 12 months
- Detachment of Device or Device Component39
- Break31
- Communication or Transmission Problem24
- Difficult to Remove22
- Contamination20
- Material Separation20
In plain English: what the newest reports describe Written by AI
Several reports describe the wireless guidewire (used to measure pressure in heart arteries) bending, kinking, deforming or having difficulty advancing or torquing. Users switched to another guidewire to finish the procedure in most of these cases.
6 reports: 2024168-2026-04089, 2024168-2026-03901, 2024168-2026-03777, 2024168-2026-03589, 2024168-2026-03989, 2024168-2026-04055
Several reports describe the tip of a pressure guidewire breaking off or tearing inside the patient. In one report the detached tip could not be retrieved with a snare and the patient needed cardiac surgery to remove it.
3 reports: 2124215-2026-51993, 2124215-2026-50860, 2024168-2026-04014
Several reports describe disposable pressure transducers (devices that convert blood pressure into readings) leaking from the drip chamber, housing, or tubing joint. In one case the tubing had fully detached from its bond. Reports say no patient injury was alleged.
2 reports: 2015691-2026-19694, 2015691-2026-19202
Evaluation of pressure tubing in two transducer reports found dark particles inside the line, and one report describes a burn mark on the tubing. The source of these particles was not identified.
2 reports: 2015691-2026-19694, 2015691-2026-19526
One report describes a stopcock (a valve on the line) on a pressure transducer shearing off, leaving sharp edges and a broken line. Another report describes an inaccurate arterial pressure reading with no alarm, which was resolved by replacing the unit.
2 reports: 50802623, 2015691-2026-18401
Written by AI from the narratives of the 20 newest reports that have one, received Sep 4, 2026 to Oct 29, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 791in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 116registered establishments that list this product code
Watch DXO in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get DXO every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in DXO. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:DXORetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:DXORetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:DXO · count decision_dateRetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:DXORetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:DXO · count event_date_initiatedRetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:DXO · count res_event_numberRetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1959-2021" "Z-1960-2021" "Z-1961-2021" "Z-1962-2021" "Z-1963-2021")Retrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:DXO AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:DXO AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:DXO AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:DXORetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:DXORetrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:870.2870Retrieved Nov 29, 2026, 6:26 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil