FDA product code
DXE: Catheter, Embolectomy (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 870.5150
- Review panel
- Cardiovascular
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 740 in the last 12 months
- Median review time
- 183 daysthe latest 25 decisions
- Recall records
- 582 in the last 12 months
510(k) and De Novo decisions
Decisions for product code DXE per year, by decision date, 74 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 2 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 1 |
| 2021 | 1 |
| 2022 | 1 |
| 2023 | 0 |
| 2024 | 5 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K240078 | Fogarty Thru-Lumen Embolectomy CatheterEdwards Lifesciences, LLC | Aug 28, 2024230 days |
| K241330 | Fogarty Fortis Arterial Embolectomy CatheterEdwards Lifesciences | Jul 2, 202453 days |
| K233819 | Fogarty Venous Thrombectomy CathetersEdwards Lifesciences, LLC | May 22, 2024173 days |
| K233820 | Fogarty Arterial Embolectomy Catheter with Gate ValveEdwards Lifesciences | May 22, 2024173 days |
| K233619 | Fogarty Corkscrew Catheters; Fogarty Graft Thrombectomy CathetersEdwards Lifesciences | May 20, 2024189 days |
| K213771 | Merlin Aspiration SystemMivi Neurovascular, Inc. | Jan 27, 202256 days |
| K202049 | Python Catheter/Over-the-Wire Latis Graft Cleaning CatheterApplied Medical Resources Corporation | Sep 7, 2021410 days |
| K193379 | Fogarty Arterial Embolectomy Catheter, Fogarty Biliary Balloon ProbeEdwards Lifesciences, LLC | Jun 12, 2020190 days |
| K163031 | Bunegin-Albin Air Aspiration SetCook Incorporated | Jul 27, 2017269 days |
| K163353 | Needle's Eye Snare Retrieval Set - 54cmCook Incorporated | Jul 11, 2017223 days |
Recalls
Recall records for product code DXE per year, by the date the recall began. Each recalled product is one record; these 58 records belong to 31 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 1 |
| 2018 | 0 |
| 2019 | 3 |
| 2020 | 2 |
| 2021 | 4 |
| 2022 | 3 |
| 2023 | 1 |
| 2024 | 1 |
| 2025 | 1 |
| 2026 (so far) | 2 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-0117-2027Class II | LeMaitre Vascular, Inc.Devices failed in process testing related to the amount of pull force it can sustain prior to the balloon components failing. | Aug 28, 2026 |
| Z-2526-2026Class II | PFM MEDICAL INC.A snare catheter including luer lock, indicated for removal or manipulation of a foreign body in the vascular system, failed to meet the biocompatibility requi… | Apr 21, 2026 |
| Z-1750-2025Class II | LeMaitre Vascular, Inc.During internal product testing, it was observed that some packages to have incomplete seals (sterile barrier). | Apr 11, 2025 |
| Z-1824-2024Class II | LeMaitre Vascular, Inc.The guide tip can become damaged and result in the tip detaching. | Apr 17, 2024 |
| Z-0238-2024Class II | Edwards Lifesciences, LLCInadvertent release of embolectomy catheters that may experience slower than normal balloon deflation (greater-than 15 seconds). | Sep 7, 2023 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code DXE. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
This section didn’t load from openFDA. It’s retried within the hour.
Last 12 months by event type
This section didn’t load from openFDA. It’s retried within the hour.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 591in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 102registered establishments that list this product code
Other codes under 21 CFR 870.5150
Product codes classified under the same regulation.
Watch DXE in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get DXE every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in DXE. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:DXERetrieved Nov 28, 2026, 8:41 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:DXERetrieved Nov 28, 2026, 8:41 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:DXE · count decision_dateRetrieved Nov 28, 2026, 8:41 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:DXERetrieved Nov 28, 2026, 8:41 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:DXE · count event_date_initiatedRetrieved Nov 28, 2026, 8:41 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:DXE · count res_event_numberRetrieved Nov 28, 2026, 8:41 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-0117-2027" "Z-2526-2026" "Z-1750-2025" "Z-1824-2024" "Z-0238-2024")Retrieved Nov 28, 2026, 8:41 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:DXERetrieved Nov 28, 2026, 8:41 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:DXERetrieved Nov 28, 2026, 8:41 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:870.5150Retrieved Nov 28, 2026, 5:09 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil