Product codes

FDA product code

DRY: Monitor, Blood-Gas, On-Line, Cardiopulmonary Bypass (FDA product code)

Follow DRY: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 870.4330
Review panel
Cardiovascular
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
470 in the last 12 months
Median review time
87 daysthe latest 25 decisions
Recall records
400 in the last 12 months
Adverse event reports
121last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code DRY per year, by decision date, 47 since 1981. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20183
20190
20201
20211
20220
20230
20241
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K234065 CDI OneView Monitoring SystemTerumo Cardiovascular Systems Corporation Apr 25, 2024125 days
K202154 B-CaptaLivanova Deutschland, GmbH Apr 1, 2021241 days
K202557 Quantum Workstation 12 EliteSpectrum Medical , Ltd. Oct 2, 202029 days
K182110 CDI Blood Parameter Monitoring System 550Terumo Cardiovascular Systems Corporation Nov 2, 201888 days
K181923 Quantum Workstation 12.1Spectrum Medical , Ltd. Aug 17, 201830 days
K173591 Quantum Diagnostic Module, Quantum Diagnostic Module - No GasSpectrum Medical , Ltd. Mar 28, 2018127 days
K163657 Quantum WorkstationSpectrum Medical , Ltd. Jan 18, 201726 days
K133157 TRI-OPTIC MEASUREMENT CELL; WITH BALANCE BIOSURFACE, WITH CARMEDA BIOACTIVE SURFACE, WITH TRILLIUM BIOSURFACE, WITH 6Medtronic, Inc. Oct 23, 2014371 days
K133658 CDI BLOOD PARAMETER MONITORING SYSTEM 500Terumo Cardiovascular Systems Corp. Jul 25, 2014240 days
K123039 CDI BLOOD PARAMETER MONITORING SYSTEM 500Terumo Cardiovascular Systems Corp. Nov 20, 201253 days

Recalls

Recall records for product code DRY per year, by the date the recall began. Each recalled product is one record; these 40 records belong to 18 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20182
20190
20201
20210
20220
20230
20240
20252
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2018-2025Class II Terumo Cardiovascular Systems CorporationDue to an error in assembly of the thermistor within some units, the affected probes will experience inaccuracy in measured shunt sensor temperature. Additiona… May 28, 2025
Z-1492-2025Class II Terumo Cardiovascular Systems CorporationDuring some clinical cases, it has been observed that the SO2 value may periodically appear as dashes on the Touchscreen Display indicating unavailable data. I… Mar 3, 2025
Z-0443-2021Class II Maquet Cardiovascular Us Sales, LlcThe Printed Circuit Board Assembly (PCBA) are not in compliance with the IEC standard (60601 1, third edition). The BMU 40 units affected by this recall were d… Sep 30, 2020
Z-2750-2018Class II Terumo Cardiovascular Systems CorporationH/Sat Hybrid Intensity Shift has been seen in a subset of the H/Sat population, which has resulted in an increase of Hybrids failing the H/Sat Color Chip Test… Jun 26, 2018
Z-2751-2018Class II Terumo Cardiovascular Systems CorporationH/Sat Hybrid Intensity Shift has been seen in a subset of the H/Sat population, which has resulted in an increase of Hybrids failing the H/Sat Color Chip Test… Jun 26, 2018

Adverse event reports (MAUDE)

Medical device reports received per year that name product code DRY. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201761
2018165
201963
202035
202142
202237
202341
202472
2025139
2026 (so far)107

Last 12 months by event type

  • Deaths0
  • Injuries2
  • Malfunctions119
  • Other or not stated0

Most reported device problems, last 12 months

  1. Incorrect, Inadequate or Imprecise Result or Readings33
  2. Device Sensing Problem25
  3. Leak/Splash12
  4. Failure to Sense9
  5. Pumping Stopped7
  6. Incorrect Measurement4

In plain English: what the newest reports describe Written by AI

  • Four reports describe bubble or level sensor alarms. Two describe bubble alarms sounding with no air present. One describes a level sensor error cleared by pressing the sensor, and one describes a level alarm that slowed the pump until the user disabled the sensor.

    4 reports: 3006073153-2026-00158, 3006073153-2026-00159, 3006073153-2026-00188, 3006073153-2026-00164

  • Three reports describe the blood gas monitor giving readings that seem wrong. Two describe drift from the blood gas analyzer or an inaccurate analyzer sensor note. One describes pH values higher than expected, which the team recalibrated. No patient consequences were reported.

    3 reports: 1828100-2026-00317, 1828100-2026-00298, 1828100-2026-00197

  • Two reports describe leaking. One found buffer solution leaking inside the package before use. The other saw leakage during priming, before bypass, and the product was replaced with a backup. No patient was involved.

    2 reports: 1124841-2026-00072, 1124841-2026-00068

  • Two reports describe the main control unit shutting down during a case. In one it got stuck on the startup screen with a hardware error and a backup unit finished. In the other it restarted twice, with other modules still running. No patient harm was reported.

    2 reports: 3006073153-2026-00192, 3006073153-2026-00174

  • Two reports describe the flow dropping suddenly. One saw a drop from full flow to 0.5 liters per minute without apparent reason, and the other had difficulty re-establishing flow after it had been zero. The user restored adequate flow in both, and no patient harm was reported.

    2 reports: 3006073153-2026-00157, 3006073153-2026-00153

Written by AI from the narratives of the 18 newest reports that have one, received Jun 15, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
126in the FDA’s Global Unique Device Identification Database
Establishment listings
39registered establishments that list this product code

Watch DRY in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get DRY every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in DRY. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.