Product codes

FDA product code

DRM: Compressor, Cardiac, External (FDA product code)

Follow DRM: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 870.5200
Review panel
Cardiovascular
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
450 in the last 12 months
Median review time
112 daysthe latest 25 decisions
Recall records
121 in the last 12 months
Adverse event reports
1,015last 12 months, 15 deaths

510(k) and De Novo decisions

Decisions for product code DRM per year, by decision date, 45 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20181
20190
20200
20211
20220
20231
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K221700 AutoPulse NXT Resuscitation SystemZoll Circulation, Inc. Mar 9, 2023269 days
K211289 RMU-2000 Automated Chest Compression SystemDefibtech, LLC Nov 9, 2021195 days
K173553 LUCAS 3 Chest Compression SystemJolife AB Feb 8, 201884 days
K161768 LUCAS 3 Chest Compression SystemJolife AB Nov 9, 2016135 days
K153628 ROSC-U Mini Chest Compressor (RMCC)Resuscitation International, LLC Jan 30, 201643 days
K141809 RMU-1000 AUTOMATED CHEST COMPRESSION SYSTEMDefibtech, LLC Oct 27, 2014112 days
K112998 AUTOPULSE RESUSCITATION SYSTEM MODEL 1000Zoll Circulation Mar 15, 2012160 days
K102068 MINIATURIZE CHEST COMPRESSOR (MCC)Resuscitation International Nov 16, 2010116 days
K090422 LUCAS 2Jolife AB Jun 17, 2009119 days
K072527 AUTOPULSE RESUSCITATION SYSTEM, MODEL 100Zoll Circulation Mar 19, 2008194 days

Recalls

Recall records for product code DRM per year, by the date the recall began. Each recalled product is one record; these 12 records belong to 12 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20181
20190
20200
20210
20221
20230
20241
20252
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-2161-2026Class II Jolife ABDue to a subset of chest compression systems/devices where the service performed on the systems were not appropriately documented (The documents for the servic… Apr 13, 2026
Z-1998-2025Class II Jolife ABDue to demonstration units of chest compression system being provided to a customer which may potentially be utilized for clinical use. May 21, 2025
Z-1533-2025Class I ZOLL Circulation, Inc.AutoPulse NXT Resuscitation System may not provide adequate chest compressions or may stop compressions due to code FC1060. Mar 4, 2025
Z-2543-2024Class I Defibtech, LLCProblem in the device's motor may cause the device to stop compressions. This may lead to a delay in therapy if the device fails to operate, and could lead to… Jul 12, 2024
Z-0118-2023Class II ZOLL Circulation, Inc.Due to increase in Li-Ion Battery failures Sep 22, 2022

Adverse event reports (MAUDE)

Medical device reports received per year that name product code DRM. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017679
2018783
2019706
2020844
2021755
2022730
2023765
2024710
2025698
2026 (so far)924

Last 12 months by event type

  • Deaths15
  • Injuries18
  • Malfunctions980
  • Other or not stated2

Most reported device problems, last 12 months

  1. Electrical /Electronic Property Problem346
  2. Visual Prompts will not Clear262
  3. Use of Device Problem129
  4. Key or Button Unresponsive/not Working77
  5. Mechanical Jam62
  6. Battery Problem25

In plain English: what the newest reports describe Written by AI

  • Several reports describe the device stopping, pausing, or alarming during chest compressions on a patient, so it could not provide automated compressions. The device instructions say the user should remove it and start manual chest compressions.

    10 reports: 3005445717-2026-00461, 3005445717-2026-00457, 3005445717-2026-00458, 3005445717-2026-00451, 3005445717-2026-00452, 3005445717-2026-00453, 3005445717-2026-00454, 3005445717-2026-00448, 3005445717-2026-00449, 3005445717-2026-00450

  • Several reports describe the device's internal fault codes or warning messages during shift checks or calls, including a fan fault, an encoder fault, and a system error telling the crew to revert to manual CPR. No patient was involved in these reports.

    3 reports: 3010617000-2026-00641, 3010617000-2026-00651, 3010617000-2026-00634

  • Two reports describe the device displaying a message to pull up the LifeBand strap and restart the device after a few compressions. In one, readjusting the strap did not fix the problem. In both, the crew switched to manual CPR and the reports state no effect on the patient.

    2 reports: 3010617000-2026-00645, 3010617000-2026-00649

  • In one report, the device powered on but did not deliver compressions when applied to a patient found not breathing at home. Manual CPR continued for about 40 minutes, and the report says the patient survived to the hospital but did not survive to discharge.

    Report: 3003521780-2026-01871

  • One report describes a band spool on the platform rotated inward, blocking proper band installation. The manufacturer's support gave instructions that slightly helped, but the band pin still did not lock into place. The report says it is unknown when the problem began.

    Report: 3010617000-2026-00655

Written by AI from the narratives of the 20 newest reports that have one, received Oct 14, 2026 to Oct 28, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
341in the FDA’s Global Unique Device Identification Database
Establishment listings
35registered establishments that list this product code

Watch DRM in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get DRM every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in DRM. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.