Product codes

FDA product code

DFH: Kappa, Antigen, Antiserum, Control (FDA product code)

Follow DFH: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 866.5550
Review panel
Immunology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
631 in the last 12 months
Median review time
242 daysthe latest 25 decisions
Recall records
20 in the last 12 months
Adverse event reports
22last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code DFH per year, by decision date, 63 since 1978. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20183
20191
20200
20212
20224
20230
20242
20252
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K253358 Diazyme Human Kappa (k) Free Light Chain Assay; Diazyme Human Lambda (¿) Free Light Chain AssayDiazyme Laboratories, Inc. Dec 19, 202580 days
K250549 Optilite® Freelite Mx Kappa Free Kit; Optilite® Freelite Mx Lambda Free KitThe Binding Site Group , Ltd. May 23, 202587 days
K231601 FLC Kappa, FLC Lambda,FLC Control Level 1, FLC Control Level 2Sebia Feb 23, 2024267 days
K231290 Optilite® Freelite® Kappa Free Kit, Optilite® Freelite® Lambda Free KitThe Binding Site, Ltd. Jan 24, 2024265 days
K210623 FLC Kappa, FLC Lambda, FLC Control Level 1, FLC Control Level 2Sebia Nov 18, 2022626 days
K211648 Diazyme Human Kappa Free Light Chain Assay, Diazyme Human Lambda Free Light Chain AssayDiazyme Laboratories, Inc. Sep 8, 2022468 days
K220001 Diazyme Human Kappa Free Light Chain Assay, Diazyme Human Lambda Free Light Chain AssayDiazyme Laboratories, Inc. Aug 4, 2022212 days
K212379 N Latex FLC kappa, N Latex FLC lambdaSiemens Healthcare Diagnostics Products GmbH Mar 2, 2022212 days
K201496 N Latex FLC kappa, N Latex FLC lambdaSiemens Healthcare Diagnostics Products GmbH Oct 29, 2021511 days
K193047 N Latex FLC kappa, N Latex FLC lambdaSiemens Healthcare Diagnostics Products GmbH Jul 14, 2021621 days

Recalls

Recall records for product code DFH per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20201
20211
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2030-2021Class II The Binding Site Group, Ltd.The high and low level "Quality Controls" demonstrate a positive bias of approximately 10% compared to assigned values. May 20, 2021
Z-0943-2021Class II The Binding Site Group, Ltd.Due to customer complaints of positive bias impacting quality control. The high and low level controls are demonstrating a positive bias compared to assigned v… Nov 18, 2020

Adverse event reports (MAUDE)

Medical device reports received per year that name product code DFH. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20171
20180
20194
20200
20211
202211
20233
202413
202510
2026 (so far)20

Last 12 months by event type

  • Deaths0
  • Injuries6
  • Malfunctions16
  • Other or not stated0

Most reported device problems, last 12 months

  1. High Test Results10
  2. Low Test Results10
  3. Incorrect, Inadequate or Imprecise Result or Readings2

In plain English: what the newest reports describe Written by AI

  • Four reports describe falsely low kappa free light chain results on other analyser models, in some cases with lambda results also low. The alternate method was considered correct in these cases. No patient harm was reported.

    4 reports: 9610806-2026-00038, 9610806-2026-00021, 9610806-2025-00023, 9610806-2025-00011

  • Three reports describe falsely low kappa free light chain results from the Freelite test on the analyser. Two of them say the cause was a problem specific to the laboratory site, and the manufacturer reported that 15 wrong results had been released in one case, which were then corrected. Two reports note that such a low result could cause serious harm if considered alone.

    3 reports: 2083566-2026-00008, 2083566-2026-00003, 2083566-2025-00003

  • Three reports describe falsely high kappa free light chain results from the Freelite test, which led to a bone marrow biopsy or PET-CT scan that was later judged unnecessary. No deaths or complications from these procedures were reported.

    3 reports: 2083566-2026-00005, 9614373-2026-00005, 2083566-2026-00002

  • Three reports describe kappa results on one analyser model that did not agree with repeat testing. In one report the alternate method result was reported as correct, and in another it is unknown which result was correct. No patient harm was reported.

    3 reports: 9610806-2026-00001, 9610806-2025-00056, 9610806-2025-00031

  • One report describes falsely high results on an analyser model after multiple dilutions of the sample. No results were reported to the physician, and no patient harm was reported.

    Report: 9610806-2025-00055

Written by AI from the narratives of the 15 newest reports that have one, received Mar 26, 2025 to Oct 28, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
45in the FDA’s Global Unique Device Identification Database
Establishment listings
46registered establishments that list this product code

Watch DFH in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get DFH every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in DFH. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.