CGL: Electrode, Ion Based, Enzymatic, Creatinine (FDA product code)

Follow CGL: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 862.1225
Review panel
Clinical Chemistry
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
81 in the last 12 months
Median review time
104 daysthe latest 8 decisions
Recall records
90 in the last 12 months
Adverse event reports
10last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code CGL per year, by decision date, 8 since 1991. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
K261039 i-STAT Crea cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc. Jun 26, 202688 days
K171059 Nova StatSensor Creatinine Hospital Meter SystemNova Biomedical Corporation May 26, 201746 days
K113726 EPOC CHLORIDE TEST AND EPOC CREATININE TESTEpocal, Inc. Oct 5, 2012291 days
K070068 NOVA STATSENSOR CREATININE HOSPITAL METER, CONTROL SOLUTIONS,LINEARITY SOLUTIONS, AND TEST STRIPSNova Biomedical Corp. May 7, 2007119 days
K051968 ABL8X7 FLEXRadiometer Medical Aps Oct 16, 2006453 days
K991727 STAT PROFILE M7 ANALYZERNova Biomedical Corp. Jul 16, 199957 days
K973292 I-STAT SYSTEMI-Stat Corp. Oct 20, 199748 days
K903034 RENALYZER PRX 90Swedish Trade Council USA Mar 13, 1991245 days

Recalls

Recall records for product code CGL per year, by the date the recall began. Each recalled product is one record; these 9 records belong to 7 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20251
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1846-2025Class II Mckesson Medical-Surgical Inc. Corporate Officetransit delays of certain cold chain products due to severe thunderstorms which may caused the products to be stored outside the recommended labeled storage co… Apr 24, 2025
Z-1293-2015Class II Radiometer America IncNegative drift on QC during in-use lifetime of CREA membranes can be observed. Oct 29, 2014
Z-1008-2012 Radiometer America IncWhen the user activates the dosicap (containing the crea additive) and mounts it onto the bottle, the threads will not seal correctly causing approximately 10%… Dec 16, 2011
Z-0456-2011 Abbott Point of Care Inc.The i-STAT CREA Cartridges may produce inaccurate (depressed) results at or near the end of the labeled expiry date when stored above 25 degrees for 2 weeks. Mar 17, 2010
Z-1015-2010 Radiometer America IncAnalysis of customer data, (for ABL 8X7 customers) has shown that the reference membranes are out of analytical specifications when replaced as specified in th… Mar 26, 2009

Adverse event reports (MAUDE)

Medical device reports received per year that name product code CGL. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201714
201811
201925
202019
202120
202211
20235
20247
20258
2026 (so far)10

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions10
  • Other or not stated0

Most reported device problems, last 12 months

  1. Incorrect, Inadequate or Imprecise Result or Readings8
  2. Computer Software Problem1
  3. Low Test Results1

In plain English: what the newest reports describe Written by AI

  • Several reports describe the handheld creatinine test giving readings that differ from laboratory results, often higher than the lab value. Creatinine is a blood marker of kidney function. In one 2026 report the manufacturer found the results matched a known interference from the drug hydroxyurea, though the customer said the patient was not taking it, and it said there was no reason to suspect a malfunction.

    10 reports: 2245578-2026-00138, 2245578-2026-00124, 2245578-2026-00125, 2245578-2025-00127, 2245578-2025-00102, 2245578-2025-00097, 2245578-2025-00056, 2245578-2024-00215, 2245578-2024-00209, 2245578-2026-00108

  • In two 2025 reports, a low creatinine reading from the handheld test was followed by contrast dye being given to the patient, while the laboratory result was much higher. Contrast dye is used for scans and can strain the kidneys when kidney function is poor. In one report the dose was reduced, and in the other saline was given to dilute the dye.

    2 reports: 1219029-2025-00026, 1219029-2025-00025

  • One 2026 report says a patient was given contrast for a CT scan based on the handheld test result, which differed from the lab result. The report gives no further detail about the patient or outcome.

    Report: 1219029-2026-00037

  • Two 2026 reports describe creatinine overload errors that persisted across calibrations and membrane changes, and a customer delay in using the analyzer when needed. Calibration is a process to check the device's accuracy. The reports do not state the cause or the outcome.

    Report: 1219029-2026-00030

  • One 2025 report notes that test strips were stored in a refrigerator, returned to cold storage after each use, and used without first warming to room temperature. Quality checks were not done within 24 hours of the reading. The report does not confirm these steps caused the difference in results.

    Report: 1219029-2025-00026

Written by AI from the narratives of the 14 newest reports that have one, received Dec 3, 2024 to Jun 26, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
123in the FDA’s Global Unique Device Identification Database
Establishment listings
27registered establishments that list this product code

Watch CGL in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get CGL every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in CGL. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.