Product codes

FDA product code

CBK: Ventilator, Continuous, Facility Use (FDA product code)

Follow CBK: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 868.5895
Review panel
Anesthesiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
Yes
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
510(k) and De Novo decisions
5054 in the last 12 months
Median review time
265 daysthe latest 25 decisions
Recall records
33523 in the last 12 months
Adverse event reports
14,267last 12 months, 68 deaths

510(k) and De Novo decisions

Decisions for product code CBK per year, by decision date, 505 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20176
20184
20198
20205
20216
20220
20235
20249
20254
2026 (so far)3

Latest decisions

NumberDevice and applicantDecision and review time
K253647 Evita (V800, V600)Draegerwerk AG & CO Kgaa May 7, 2026168 days
K252663 Inbentus VersatileIconic Solutions by Murcia, SL Apr 14, 2026235 days
K251888 VPAP Pediatric Face MaskHsiner Co., Ltd. Mar 12, 2026265 days
K232365 Vivo 45 LSOconnell Regulatory Consultants, Inc. Dec 19, 2025865 days
K252173 F&P OptiNIV Hospital Vented Full Face Mask Compatible with Single-limb Circuits – Size A (ONIV117A); F&P OptiNIV Hospital Vented Full Face Mask Compatible with Single-limb Circuits – Size B (ONIV117B); F&P OptiNIV Hospital Vented Full Face Mask Compatible with Single-limb Circuits – Size C (ONIV117C); F&P OptiNIV ONIV117-F Hospital Vented Full Face Mask with optional Expiratory Filter Compatible with Single-limb Circuits - Size A (ONIV117A-F); F&P OptiNIV ONIV117-F Hospital Vented FullFisher & Paykel Healthcare, Ltd. Sep 10, 202561 days
K243767 SV600, SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. Aug 28, 2025265 days
K251133 AVEA disposable expiratory filter/water trap (11790)Telesair, Inc. May 8, 202527 days
K243394 AF531 Oro-Nasal SE Face MaskRespironics, Inc. Dec 30, 202460 days
K233486 731 Series VentilatorZOLL Medical Corporation Dec 13, 2024413 days
K223120 Ventoux VC2; Ventoux VC3Flight Medical Innovations , Ltd. Dec 2, 2024791 days

Recalls

Recall records for product code CBK per year, by the date the recall began. Each recalled product is one record; these 335 records belong to 190 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20175
201810
201916
20205
202129
202213
202333
202426
20258
2026 (so far)23

Latest recalls

Recall and classFirm and reasonBegan
Z-0122-2027Class I Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… Sep 17, 2026
Z-0123-2027Class I Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… Sep 17, 2026
Z-0124-2027Class I Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… Sep 17, 2026
Z-0125-2027Class I Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… Sep 17, 2026
Z-0126-2027Class I Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… Sep 17, 2026

Adverse event reports (MAUDE)

Medical device reports received per year that name product code CBK. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201714,451
20189,849
20199,100
202011,096
202113,322
202215,974
202324,928
202420,337
202514,199
2026 (so far)13,037

Last 12 months by event type

  • Deaths68
  • Injuries200
  • Malfunctions13,985
  • Other or not stated14

Most reported device problems, last 12 months

  1. Electrical /Electronic Property Problem2,868
  2. Failure to Calibrate1,758
  3. Mechanical Problem1,620
  4. Circuit Failure1,298
  5. Insufficient Flow or Under Infusion1,201
  6. Failure of Device to Self-Test961

In plain English: what the newest reports describe Written by AI

  • Six reports describe ventilators failing the Pre-use Check, a self-test run before use. The failures involved the pressure transducer (a sensor that measures airway pressure), an internal leakage test, or multiple tests. No patient was involved, and no cause or fix is given.

    6 reports: 8010042-2026-0001516, 8010042-2026-0001517, 8010042-2026-0001518, 8010042-2026-0001519, 8010042-2026-0001521, 8010042-2026-0001522

  • A few reports describe warnings or shutdowns during patient use. One ventilator entered a safety mode and an extra device was needed, and another rebooted during surgery and was swapped out. Other reports describe an exhalation alarm when connecting a patient and an oxygen supply failure message, and none reported lasting patient harm.

    4 reports: 3001421318-2026-00723, 9611500-2026-00548, 3001421318-2026-00721, 1220908-2026-04432

  • Three reports involve battery problems. Two show a battery cell under-voltage error, meaning a cell's charge fell too low, and one of those had no confirmed cause and no part replaced. A third reports a battery-depleted alarm while external power was connected and working.

    3 reports: 2518422-2026-049094, 2518422-2026-049110, 9611500-2026-00547

  • Three reports describe screen problems. One says the screen went blank, but the manufacturer has not yet confirmed this. Two others describe a malfunctioning screen with constant alarms or an hourglass icon, and a display board or LCD screen was replaced.

    3 reports: 2518422-2026-049096, 2518422-2026-049097, 2518422-2026-049098

  • One report says a ventilator's sensors drifted beyond what the device could compensate for, and multiple sensors read their maximum or minimum values for long periods. Device logs were unavailable, so the date of the most recent error is unknown.

    Report: 2518422-2026-049084

Written by AI from the narratives of the 19 newest reports that have one, received Oct 29, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
2,317in the FDA’s Global Unique Device Identification Database
Establishment listings
387registered establishments that list this product code

Watch CBK in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get CBK every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in CBK. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.