FDA product code
CBK: Ventilator, Continuous, Facility Use (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 868.5895
- Review panel
- Anesthesiology
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- Yes
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Ineligible
- 510(k) and De Novo decisions
- 5054 in the last 12 months
- Median review time
- 265 daysthe latest 25 decisions
- Recall records
- 33523 in the last 12 months
- Adverse event reports
- 14,267last 12 months, 68 deaths
510(k) and De Novo decisions
Decisions for product code CBK per year, by decision date, 505 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 6 |
| 2018 | 4 |
| 2019 | 8 |
| 2020 | 5 |
| 2021 | 6 |
| 2022 | 0 |
| 2023 | 5 |
| 2024 | 9 |
| 2025 | 4 |
| 2026 (so far) | 3 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K253647 | Evita (V800, V600)Draegerwerk AG & CO Kgaa | May 7, 2026168 days |
| K252663 | Inbentus VersatileIconic Solutions by Murcia, SL | Apr 14, 2026235 days |
| K251888 | VPAP Pediatric Face MaskHsiner Co., Ltd. | Mar 12, 2026265 days |
| K232365 | Vivo 45 LSOconnell Regulatory Consultants, Inc. | Dec 19, 2025865 days |
| K252173 | F&P OptiNIV Hospital Vented Full Face Mask Compatible with Single-limb Circuits – Size A (ONIV117A); F&P OptiNIV Hospital Vented Full Face Mask Compatible with Single-limb Circuits – Size B (ONIV117B); F&P OptiNIV Hospital Vented Full Face Mask Compatible with Single-limb Circuits – Size C (ONIV117C); F&P OptiNIV ONIV117-F Hospital Vented Full Face Mask with optional Expiratory Filter Compatible with Single-limb Circuits - Size A (ONIV117A-F); F&P OptiNIV ONIV117-F Hospital Vented FullFisher & Paykel Healthcare, Ltd. | Sep 10, 202561 days |
| K243767 | SV600, SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. | Aug 28, 2025265 days |
| K251133 | AVEA disposable expiratory filter/water trap (11790)Telesair, Inc. | May 8, 202527 days |
| K243394 | AF531 Oro-Nasal SE Face MaskRespironics, Inc. | Dec 30, 202460 days |
| K233486 | 731 Series VentilatorZOLL Medical Corporation | Dec 13, 2024413 days |
| K223120 | Ventoux VC2; Ventoux VC3Flight Medical Innovations , Ltd. | Dec 2, 2024791 days |
Recalls
Recall records for product code CBK per year, by the date the recall began. Each recalled product is one record; these 335 records belong to 190 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 5 |
| 2018 | 10 |
| 2019 | 16 |
| 2020 | 5 |
| 2021 | 29 |
| 2022 | 13 |
| 2023 | 33 |
| 2024 | 26 |
| 2025 | 8 |
| 2026 (so far) | 23 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-0122-2027Class I | Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… | Sep 17, 2026 |
| Z-0123-2027Class I | Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… | Sep 17, 2026 |
| Z-0124-2027Class I | Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… | Sep 17, 2026 |
| Z-0125-2027Class I | Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… | Sep 17, 2026 |
| Z-0126-2027Class I | Ventec Life Systems, Inc.Ventilator's Internal Flow transducer cable connector may disconnect from internal board, potentially resulting in system reboot and interruption of ventilatio… | Sep 17, 2026 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code CBK. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 14,451 |
| 2018 | 9,849 |
| 2019 | 9,100 |
| 2020 | 11,096 |
| 2021 | 13,322 |
| 2022 | 15,974 |
| 2023 | 24,928 |
| 2024 | 20,337 |
| 2025 | 14,199 |
| 2026 (so far) | 13,037 |
Last 12 months by event type
- Deaths68
- Injuries200
- Malfunctions13,985
- Other or not stated14
Most reported device problems, last 12 months
- Electrical /Electronic Property Problem2,868
- Failure to Calibrate1,758
- Mechanical Problem1,620
- Circuit Failure1,298
- Insufficient Flow or Under Infusion1,201
- Failure of Device to Self-Test961
In plain English: what the newest reports describe Written by AI
Six reports describe ventilators failing the Pre-use Check, a self-test run before use. The failures involved the pressure transducer (a sensor that measures airway pressure), an internal leakage test, or multiple tests. No patient was involved, and no cause or fix is given.
6 reports: 8010042-2026-0001516, 8010042-2026-0001517, 8010042-2026-0001518, 8010042-2026-0001519, 8010042-2026-0001521, 8010042-2026-0001522
A few reports describe warnings or shutdowns during patient use. One ventilator entered a safety mode and an extra device was needed, and another rebooted during surgery and was swapped out. Other reports describe an exhalation alarm when connecting a patient and an oxygen supply failure message, and none reported lasting patient harm.
4 reports: 3001421318-2026-00723, 9611500-2026-00548, 3001421318-2026-00721, 1220908-2026-04432
Three reports involve battery problems. Two show a battery cell under-voltage error, meaning a cell's charge fell too low, and one of those had no confirmed cause and no part replaced. A third reports a battery-depleted alarm while external power was connected and working.
3 reports: 2518422-2026-049094, 2518422-2026-049110, 9611500-2026-00547
Three reports describe screen problems. One says the screen went blank, but the manufacturer has not yet confirmed this. Two others describe a malfunctioning screen with constant alarms or an hourglass icon, and a display board or LCD screen was replaced.
3 reports: 2518422-2026-049096, 2518422-2026-049097, 2518422-2026-049098
One report says a ventilator's sensors drifted beyond what the device could compensate for, and multiple sensors read their maximum or minimum values for long periods. Device logs were unavailable, so the date of the most recent error is unknown.
Report: 2518422-2026-049084
Written by AI from the narratives of the 19 newest reports that have one, received Oct 29, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 2,317in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 387registered establishments that list this product code
Other codes under 21 CFR 868.5895
Product codes classified under the same regulation.
Watch CBK in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get CBK every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in CBK. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:CBKRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:CBKRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:CBK · count decision_dateRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:CBKRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:CBK · count event_date_initiatedRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:CBK · count res_event_numberRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-0122-2027" "Z-0123-2027" "Z-0124-2027" "Z-0125-2027" "Z-0126-2027")Retrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:CBK AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:CBK AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:CBK AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:CBKRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:CBKRetrieved Nov 29, 2026, 7:16 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:868.5895Retrieved Nov 29, 2026, 4:13 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil