CAW: Generator, Oxygen, Portable (FDA product code)

Follow CAW: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 868.5440
Review panel
Anesthesiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
28911 in the last 12 months
Median review time
218 daysthe latest 25 decisions
Recall records
441 in the last 12 months
Adverse event reports
653last 12 months, 33 deaths

510(k) and De Novo decisions

Decisions for product code CAW per year, by decision date, 289 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20183
20192
20205
20212
20224
20238
20242
202512
2026 (so far)6

Latest decisions

NumberDevice and applicantDecision and review time
K254289 Portable Oxygen Concentrator (OX-1A-E, OX-1B)Oxytek Medical Technology Co., Ltd. Sep 23, 2026266 days
K260171 Portable Oxygen Concentrator (PO1 5B, PO1 6B)BMC Medical Co., Ltd. Aug 14, 2026205 days
K252399 Portable Oxygen ConcentratorHonsun (Nantong) Co., Ltd. Jun 17, 2026321 days
K252965 Oxygen Concentrator (OX-5A, OX-5C)Oxytek Medical Technology Co., Ltd. May 29, 2026254 days
K252407 OxyGo Portable Oxygen Concentrator (1400-7000)Mv Life, LLC Apr 23, 2026266 days
K253549 DeVilbiss 5 Liter Oxygen Concentrator (555)Devilbiss Healthcare, LLC Mar 26, 2026132 days
K251534 Oxygen Concentrator (J10A)Foshan Kycare Medical Equipment Co., Ltd. Dec 29, 2025224 days
K251764 Oxygen Concentrator-P2-O5EQingdao Kingon Medical Science and Technology Co., Ltd. Dec 22, 2025196 days
K252616 Portable oxygen concentrator (JLO-190P)Shenzhen Homed Medical Device Co., Ltd. Dec 22, 2025125 days
K252268 V series portable oxygen concentrator (V5, V5C, V6, V6C)Shenzhen Harveymed Technology Co., Ltd. Dec 16, 2025148 days

Recalls

Recall records for product code CAW per year, by the date the recall began. Each recalled product is one record; these 44 records belong to 31 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20180
20192
20201
20210
20224
20231
20245
20253
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-1815-2026Class II 3B Medical, Inc.Devices which did not meet internal quality specifications were inadvertently distributed. Feb 4, 2026
Z-0481-2026Class II Philips Respironics, Inc.Certain serial numbers of the SimplyGo Mini standard battery kit contain a defective chip which can lead the battery to either fail to charge or lose voltage o… Oct 7, 2025
Z-1980-2025Class II Ohio Medical CorporationErroneous calibration values, potentially resulting in: as the device ages, oxygen purity will gradually decrease to the point where the device alarms to indic… May 8, 2025
Z-1727-2025Class I Medical Depot Inc.Potential for DC Power Supply housing to become hot to the touch and deform the plastic housing. Apr 11, 2025
Z-0795-2025Class I JIANGSU JUMAO X-CARE MEDICAL EQUIPMENT CO LTDOxygen concentrator may melt or catch on fire during use. Dec 9, 2024

Adverse event reports (MAUDE)

Medical device reports received per year that name product code CAW. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017107
2018116
2019120
2020125
2021194
2022305
2023357
2024450
2025613
2026 (so far)597

Last 12 months by event type

  • Deaths33
  • Injuries412
  • Malfunctions206
  • Other or not stated2

Most reported device problems, last 12 months

  1. Insufficient Flow or Under Infusion136
  2. Overheating of Device118
  3. Thermal Decomposition of Device85
  4. Unexpected Shutdown85
  5. No Flow69
  6. Failure to Deliver49

In plain English: what the newest reports describe Written by AI

  • Several patients reported their unit shut off, cut out, or lost power, or would not charge or connect to its battery. Some patients had lower oxygen levels, trouble breathing, or hospital stays. Replacement units or batteries were sent in some of these cases.

    6 reports: 3004672275-2026-00363, 3004672275-2026-00364, 3004672275-2026-00371, 3004672275-2026-00373, 3004672275-2026-00374, 2518422-2026-048866

  • Patients reported their unit was not giving enough oxygen, so their oxygen levels dropped. One patient's lips turned blue, and one report says a patient died from severe pulmonary hypertension, which the report alleges was caused by low oxygen.

    5 reports: 3004672275-2026-00360, 3004672275-2026-00365, 3004672275-2026-00366, 3004672275-2026-00367, 3004672275-2026-00368

  • Some units overheated, and technicians found heat damage to the internal circuit board. One unit would no longer turn on after a thermal event with burn marks. In another report, a System Hot warning appeared and the patient went to hospital with breathing difficulty.

    4 reports: 2518422-2026-049072, 2518422-2026-048866, 3004672275-2026-00356, 3004672275-2026-00363

  • Two reports describe a system error that left patients lightheaded or short of breath, and both patients were hospitalized. Troubleshooting did not resolve the problem in either report.

    2 reports: 3004672275-2026-00375, 3004672275-2026-00376

  • Two reports involve fire or explosion. One patient said the unit exploded and claimed property damage, but the device has not yet been examined. In the other, a patient tried to light it on fire, and the manufacturer's lab found soot and rust inside.

    2 reports: 2518422-2026-048996, 2518422-2026-048370

Written by AI from the narratives of the 20 newest reports that have one, received Oct 21, 2026 to Oct 29, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
642in the FDA’s Global Unique Device Identification Database
Establishment listings
194registered establishments that list this product code

Product codes classified under the same regulation.

Watch CAW in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get CAW every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in CAW. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.