BZR: Mixer, Breathing Gases, Anesthesia Inhalation (FDA product code)

Follow BZR: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 868.5330
Review panel
Anesthesiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
Yes
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
550 in the last 12 months
Median review time
161 daysthe latest 25 decisions
Recall records
30 in the last 12 months
Adverse event reports
6last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code BZR per year, by decision date, 55 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20181
20190
20200
20211
20220
20234
20241
20251
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K243917 F&P Optiflow Air/Oxygen Flow SourceFisher & Paykel Healthcare, Ltd. Jul 14, 2025206 days
K241465 Midas Flowmeter; eAVSParker Hannifin Corporation Sep 19, 2024119 days
K231895 Maxtec MaxBlend2+pMaxtec, LLC Dec 4, 2023159 days
K230987 FlowStar Analog Mixer FlowmeterBaldus Sedation GmbH & Co. KG Sep 14, 2023161 days
K222794 FlowStar Touch Digital Mixer FlowmeterBaldus Sedation GmbH & Co. KG Jul 28, 2023315 days
K221494 Quality Mix Blender, OxymixerDehas Medical Systems GmbH Jan 23, 2023245 days
K202480 Nitronox Plus 0-70, Nitronox 0-50, Nitronox Plus 50/50Parker Hannifin Apr 22, 2021237 days
K173205 Equinox AdvantageO-Two Medical Technologies, Inc. Aug 29, 2018331 days
K161718 MaxBlend 2, MaxBlend LiteMaxtec, LLC Oct 27, 2016127 days
K142291 GMX Series Medical Air/Oxygen BlenderGentec (Shanghai) Corporation May 19, 2015274 days

Recalls

Recall records for product code BZR per year, by the date the recall began. Each recalled product is one record; these 3 records belong to 3 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20182
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2887-2018Class II CAREstream Medical LLCTwo analgesic gas delivery system oxygen/nitrous oxide mixers were reported to have delivered higher levels of nitrous oxide than specification during routine… May 15, 2018
Z-2885-2018Class II O-Two Medical Technologies, Inc.Higher levels of nitrous oxide delivered than specification May 14, 2018
Recall Maquet IncSoftware update so US customers will be updated equally with worldwide customers. Ver. 5.0 will be upgraded to ver 7.0. Quality will improve and enhance functi… Jan 11, 2005

Adverse event reports (MAUDE)

Medical device reports received per year that name product code BZR. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201722
201824
201926
202015
202133
202215
202319
202418
202513
2026 (so far)6

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions6
  • Other or not stated0

Most reported device problems, last 12 months

  1. Device Alarm System2
  2. Gas Output Problem2
  3. Defective Alarm1

In plain English: what the newest reports describe Written by AI

  • Several reports say the blender stopped delivering the set oxygen mix, so patients could receive less oxygen than intended and some became desaturated (had low blood oxygen). In some cases, loose internal parts such as a control knob or shaft extender were found.

    6 reports: 21432015, 1218704-2026-00001, 1218704-2025-00004, 22001948, 1000117260-2024-00001, MW5185546

  • Several reports say the blender gave no alarm when oxygen flow failed. One warning from the manufacturer says the audible alarm may not sound when both air and oxygen inlet pressures are below 30 psig.

    4 reports: 2020676-2024-00018, 2020676-2024-00019, MW5185546, 1000117260-2024-00001

  • Four reports describe blood inside the device and heavy corrosion, found by an EU distributor and during third-party servicing. No patient or user injury was reported.

    4 reports: 2020676-2025-00020, 2020676-2025-00010, 2020676-2025-00006, 2020676-2024-00022

  • Four reports describe a resuscitation bag and mask assembled incorrectly, so they did not fit and care was delayed in the delivery room. In one, staff gave blow-by oxygen (holding tubing near the baby's face) while another device was found. No injuries were reported.

    4 reports: 2028807-2025-00018, 2028807-2025-00017, 2028807-2025-00014, 2028807-2025-00010

  • One report describes a broken flowmeter on a helium-oxygen blender that leaked and made a squealing noise while staff tried to set it up for a patient on high flow nasal cannula. The leak was found after troubleshooting.

    Report: 24130152

Written by AI from the narratives of the 18 newest reports that have one, received Oct 30, 2024 to Sep 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
384in the FDA’s Global Unique Device Identification Database
Establishment listings
61registered establishments that list this product code

Watch BZR in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get BZR every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in BZR. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.