Product codes

FDA product code

BZO: Set, Tubing And Support, Ventilator (W Harness) (FDA product code)

Follow BZO: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 868.5975
Review panel
Anesthesiology
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
880 in the last 12 months
Median review time
51 daysthe latest 25 decisions
Recall records
232 in the last 12 months

510(k) and De Novo decisions

Decisions for product code BZO per year, by decision date, 88 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K953784 UNICOR, INC. CORRUGATED TUBINGUnicor, Inc. Sep 19, 199536 days
K953785 UNICOR, INC. VENTILATOR HOSESUnicor, Inc. Sep 18, 199535 days
K952010 PRIMA VENTILATOR HOSESPrima, Inc. May 22, 199524 days
K952011 PRIMA BREATHING BAGSPrima, Inc. May 22, 199524 days
K952022 PRIMA VOLUMN VENTILATORSSPrima, Inc. May 22, 199524 days
K952012 PRIMA CUSTOM ANESTESIA CIRCUITPrima, Inc. May 22, 199524 days
K945740 INFANT FLOW SYSTEMHamilton Medical, Inc. Mar 23, 1995120 days
K944531 PRIMA, INC. CORRUGATED TUBINGPrima, Inc. Dec 2, 199478 days
K942569 VENTILATOR HOSEMed-Plastics Intl., Inc. Jun 10, 199410 days
K942572 VOLUME VENTILATORMed-Plastics Intl., Inc. Jun 10, 199410 days

Recalls

Recall records for product code BZO per year, by the date the recall began. Each recalled product is one record; these 23 records belong to 14 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20221
20237
20242
20253
2026 (so far)2

Latest recalls

Recall and classFirm and reasonBegan
Z-2992-2026Class II Medline Industries, LPNeonatal and infant heated wire breathing circuits may experience sporadic failure. The heated wire connector (pigtail) at the humidifier may exhibit discolora… Jul 13, 2026
Z-2463-2026Class I Hamilton Medical AGVentilator coaxial breathing circuit may have, expiratory valve sets with membranes sticking to valve body, not detectable during pre-operative test, which wil… May 29, 2026
Z-0031-2026Class I Percussionaire CorporationIFU update; in-line valve, with pressure relief seal may leak when used with ventilator; don't use in neonates/infants, with target tidal volumes less-than50mL… Sep 17, 2025
Z-2167-2025Class I Hamilton Medical AGVentilator coaxial breathing circuit may have a crack in blue tubing, which is used to deliver fresh gas to the patient. The crack will compromise inspiratory… Jun 26, 2025
Z-1494-2025Class I Draeger, Inc.The potential for cracks forming in the breathing circuit hose. Mar 12, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code BZO. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

This section didn’t load from openFDA. It’s retried within the hour.

Last 12 months by event type

This section didn’t load from openFDA. It’s retried within the hour.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
950in the FDA’s Global Unique Device Identification Database
Establishment listings
154registered establishments that list this product code

Watch BZO in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get BZO every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in BZO. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.