Product codes

FDA product code

BXB: Exerciser, Powered (FDA product code)

Follow BXB: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 890.5380
Review panel
Physical Medicine
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
1600 in the last 12 months
Median review time
211 daysthe latest 25 decisions
Recall records
60 in the last 12 months
Adverse event reports
3last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code BXB per year, by decision date, 160 since 1980. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K072887 G-TRAINER MEDICALAlter-G, Inc. Jan 25, 2008107 days
K003272 FLO-BOOTDiscovery Group, LLC Apr 4, 2001168 days
K952975 ANKLE CALF EXERCISER PHLEBOPUMPPrevent Products, Inc. Sep 25, 1996456 days
K953456 E-Z FLEXFluid Motion Biotechnologies, Inc. Jan 26, 1996191 days
K955105 BTE CPM-10Baltimore Therapeutic Equipment Co. Dec 29, 199551 days
K955106 BTE CPM-20Baltimore Therapeutic Equipment Co. Dec 29, 199551 days
K951028 HAMEX TWONorthern Orthopaedic Products, Inc. Dec 11, 1995279 days
K950755 FLEXMATE K500Breg, Inc. Oct 5, 1995230 days
K945733 AQUAHAB, MODEL 120-72-101Aquarius Electronics, Inc. Sep 15, 1995296 days
K951029 HAMEX ONENorthern Orthopaedic Products, Inc. Sep 15, 1995192 days

Recalls

Recall records for product code BXB per year, by the date the recall began. Each recalled product is one record; these 6 records belong to 6 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20191
20200
20210
20220
20230
20241
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-3162-2024Class II Btt Health GmbhSome power supply units in Austria and Germany had a voltage drop in the millisecond range, which led to a cancellation of the treatment and subsequent restart… Aug 1, 2024
Z-2135-2020Class II MOTEK MEDICAL B.V.The firm discovered a potential manufacturing deviation of the yoke of the Body Weight Support (BWS) Light that in rare occasions may result in the yoke detach… Jul 29, 2019
Z-1837-2013Class II Accelerated Care Plus CorporationAn anomaly in the firmware that may cause Omnicycle Elite to operate at a speed other than what was previously set when in reverse mode. Jun 12, 2013
Z-0571-2013Class II BioMotion Medical Systems, LLCBioMotion is issuing a field correction for all models of the SpineSix (SpineSix01 and SpineSix02; serial numbers 1001 through 1054) to rectify all regulatory… Nov 12, 2012
Z-3026-2011 Alter-G, IncorporatedPotential installation error on AlterG Anti-Gravity Treadmill that could cause greater than expected unweighting. Jul 15, 2011

Adverse event reports (MAUDE)

Medical device reports received per year that name product code BXB. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20174
20182
20192
20200
20212
20220
202315
20242
20254
2026 (so far)3

Last 12 months by event type

  • Deaths0
  • Injuries3
  • Malfunctions0
  • Other or not stated0

Most reported device problems, last 12 months

  1. Improper or Incorrect Procedure or Method1
  2. Use of Device Problem1

In plain English: what the newest reports describe Written by AI

  • Multiple reports describe machines that would not work. One unit was delivered and never turned on, one hand control display did not work, and in two continuous passive motion machine reports the range-of-motion settings could not be controlled or the unit was not working.

    5 reports: MW5139139, 23121529, 17622967, MW5136277, MW5129697

  • Moving parts caught or trapped a limb in four reports. A foot was trapped in a robotic walking trainer's foot lifter, a child's foot was trapped under a knee motion machine, pants were caught on a crank arm causing a deep cut needing 36 stitches, and tubing was pulled into a pedal and torn out.

    4 reports: 3003781275-2026-00002, MW5187813, MW5178970, MW5159075

  • Four reports describe error messages or lockups. In some cases the machine stopped showing error messages after working for a while, or locked up, and in two reports a replacement was issued.

    4 reports: MW5131776, MW5132874, MW5136174, MW5138072

  • Two reports describe leg fractures during sessions on the Lokomat, a robotic walking trainer. One patient's shoe came off and dragged on the treadmill, and X-rays showed fractures in the lower leg. Another patient had a thighbone crack and is known to have low bone density.

    2 reports: 3003781275-2026-00001, 3003781275-2025-00001

  • One report describes the center bolt of a spreader bar coming loose during a patient session. The caregiver steadied the patient and no injury occurred. The manufacturer found the self-locking nut was defective, with gaps out of specification, and said no other defective nuts were found in the lot.

    Report: 3030997791-2024-00001

Written by AI from the narratives of the 20 newest reports that have one, received Aug 12, 2023 to Aug 6, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
246in the FDA’s Global Unique Device Identification Database
Establishment listings
123registered establishments that list this product code

Product codes classified under the same regulation.

Watch BXB in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get BXB every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in BXB. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.