FDA product code
BRW: Protector, Dental (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class I
- Regulation
- 21 CFR 868.5820
- Review panel
- Anesthesiology
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 30 in the last 12 months
- Median review time
- 36 daysthe latest 3 decisions
- Recall records
- 00 in the last 12 months
- Adverse event reports
- 1last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code BRW per year, by decision date, 3 since 1985. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
Recalls
Recall records for product code BRW per year, by the date the recall began. Each recalled product is one record.
No recalls on record for this product code.
Adverse event reports (MAUDE)
Medical device reports received per year that name product code BRW. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 0 |
| 2018 | 2 |
| 2019 | 0 |
| 2020 | 1 |
| 2021 | 1 |
| 2022 | 1 |
| 2023 | 2 |
| 2024 | 1 |
| 2025 | 1 |
| 2026 (so far) | 1 |
Last 12 months by event type
- Deaths0
- Injuries0
- Malfunctions0
- Other or not stated1
Most reported device problems, last 12 months
- Delayed Alarm1
In plain English: what the newest reports describe Written by AI
Guards were found chipped, rough, holed, or sliced through after use. The reports do not say how the damage happened, and one notes that the patient's tooth had cut through the rubber.
5 reports: 7725929, 1314417-2018-00024, 1314417-2021-00012, 2246980-2016-00075, 567412
Parts of the guard broke off or were bitten through, and pieces ended up in the throat, the food pipe, or the lungs. In one report a swallowed guard needed a scope and anesthesia to remove, and in another a piece was breathed into the lungs.
3 reports: 21686771, 1811666-2024-00001, MW5003815
Two reports describe the jaw getting worse with a guard. One reporter said their teeth shifted after about a year of wear and that the damage is permanent; the provider called that link farfetched. The other said jaw joint pain got worse after buying a lower-quality guard.
2 reports: MW5117495, MW5110058
One report says a guard burned the gums, left a strange film on the teeth, and was followed by stomach pain. The reporter did not know what material the guard was made of.
Report: MW5096671
One report says that after a device was removed at the end of a scope procedure, its strap slipped under the head, sprang back, and struck the patient's eye, and the patient needed eye surgery.
Report: 399468
Written by AI from the narratives of the 18 newest reports that have one, received May 21, 2002 to Mar 25, 2025. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 115in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 72registered establishments that list this product code
Watch BRW in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get BRW every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in BRW. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:BRWRetrieved Nov 29, 2026, 8:02 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:BRWRetrieved Nov 29, 2026, 8:02 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:BRW · count decision_dateRetrieved Nov 29, 2026, 8:02 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:BRWRetrieved Nov 29, 2026, 8:02 PM UTC.
- device/recall · search product_code:BRW · count event_date_initiatedRetrieved Nov 29, 2026, 8:02 PM UTC.
- device/recall · search product_code:BRW · count res_event_numberRetrieved Nov 29, 2026, 8:02 PM UTC.
- device/event · search device.device_report_product_code:BRW AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 8:02 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:BRW AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 8:02 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:BRW AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 8:02 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:BRWRetrieved Nov 29, 2026, 8:02 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:BRWRetrieved Nov 29, 2026, 8:02 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:868.5820Retrieved Nov 29, 2026, 8:02 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil