FDA device news · Product code GEX
FDA 510(k) clearance
ECHOLASER X4 (K261964): Elesta S.P.A 510(k) clearance
Calenzano, IT
- Decision
- Substantially Equivalent
- Decision date
- Aug 19, 2026
- Received
- Jun 11, 2026
- 510(k) type
- Traditional
- Product code
- GEXPowered Laser Surgical Instrument
- Review panel
- General, Plastic Surgery
- Device class
- Class II
- Regulation
- 21 CFR 878.4810
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 69 daysreceipt to decision, calendar days
- Median in GEX
- 96 daysthe latest 24 other decisions
- GEX decisions
- 66in the last 12 months
- Applicant’s 510(k)s
- 4in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The ECHOLASER X4 is a surgical laser system that uses a diode laser source emitting at 1064 nm in continuous wave mode. The beam travels through optical fibers, up to four at once, and is guided to the target tissue with a needle. A touchscreen panel controls each fiber, and a footswitch activates the laser.
- What it’s cleared for
- The device is cleared to cut, vaporize, ablate, necrotize or coagulate soft tissue through interstitial irradiation, meaning light delivered inside the body through a needle-guided fiber. Listed uses include discectomy, gastrointestinal tissue ablation, BPH prostatectomy, pulmonary surgery, general surgery, genitourinary and gynecological tissue ablation, and otorhinolaryngology soft tissue work, for use by medical specialists.
- How it differs
- The summary says the device has the same technological characteristics, principle of operation, energy source and mode of use as its predicates. It describes the update as adding specificity to the indications for the same general intended use. Its maximum power of 28 W and output power stability of plus or minus 20 percent match the primary predicate.
- Testing the summary lists
- Electrical safety (IEC 60601-1)
- Electromagnetic disturbances (IEC 60601-1-2)
- Laser equipment safety (IEC 60601-2-22)
- Laser product safety (IEC 60825-1)
- Medical device software lifecycle (ANSI AAMI IEC 62304:2006/A1:2016)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K261964 took 69 calendar days from receipt to decision. Of the latest 24 other decisions in product code GEX, 18 took longer, 5 were faster, 1 took the same time; their median was 96 days.
Latest decisions in GEX
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262886 | Single Use Optical FiberQuanta System Spa · Special | Nov 5, 202680 days |
| K263063 | B`orze Inc Laser Family (Sorren/Adonis)Borze, Inc. · Traditional | Oct 30, 202659 days |
| K262349 | Diode laser device (DT25-BI, DT212-BI, DT213-BI, DT214-BI, DT215-BI)Risu Medical Technology Co., Ltd. · Traditional | Oct 27, 2026109 days |
| K262627 | Fractional CO2 Laser Therapy System (Z121)Sanhe PERFECTLASER Technology Co., Ltd. · Traditional | Oct 26, 202689 days |
| K262701 | PicoPeak Picosecond Nd:Yag Laser System (Bella-9)Beijing Sea Heart International Science and Technologyco.Ltd · Traditional | Oct 22, 202683 days |
| K262628 | Picosecond Laser treatment system (Z180)Sanhe PERFECTLASER Technology Co., Ltd. · Traditional | Oct 20, 202683 days |
| K261572 | Nd:YAG & Alexandrite Long Pulse Laser Therapy Instrument (LPDuo)Keyue (Hangzhou) Medical Information Technology Co., Ltd. · Traditional | Oct 13, 2026154 days |
| K262346 | CureLight Medical Diode Laser Systems (S3-BF45, S2-B30, S3-BF30, S2-F15, S2-H7.5)Wuhan Phomed Technology Co., Ltd. · Traditional | Oct 8, 202690 days |
| K261692 | Diode Laser Hair Removal Machine (QDTM-03)Beijing Nubway S&T Co., Ltd. · Traditional | Oct 7, 2026138 days |
| K254199 | PicoreMax (PicoreMax)BLUECORE COMPANY Co., Ltd. · Traditional | Sep 24, 2026269 days |
Other 510(k)s from Elesta S.P.A
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
Watch GEX in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get GEX every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in GEX. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K261964Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:GEXRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:GEXRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:GEX AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Elesta S.P.A"Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil