FDA device news · Product code LZA
FDA 510(k) clearance
Powder-free Nitrile Examination Gloves Tested for Use With Chemotherapy Drugs and Fentanyl Citrate (Blue and Black Color) (K261793): Maxter Healthcare, Inc. 510(k) clearance
Rosharon, TX
- Decision
- Substantially Equivalent
- Decision date
- Sep 9, 2026
- Received
- May 29, 2026
- 510(k) type
- Traditional
- Product code
- LZAPolymer Patient Examination Glove
- Review panel
- General Hospital
- Device class
- Class I
- Regulation
- 21 CFR 880.6250
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 103 daysreceipt to decision, calendar days
- Median in LZA
- 136 daysthe latest 24 other decisions
- LZA decisions
- 16in the last 12 months
- Applicant’s 510(k)s
- 1in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- Powder-free nitrile examination gloves, sold in blue and black, that are tested for use with certain chemotherapy drugs and fentanyl citrate. Nitrile is a synthetic rubber that is made from a latex-type dipping process. The gloves are single-use, non-sterile, and come in six sizes, from X-Small to XXL.
- What it’s cleared for
- The gloves are intended to be worn on the hands of examiners to prevent contamination between the patient and the examiner. The summary states they are single-use, powder-free, and non-sterile, and that they were tested for use with the listed chemotherapy drugs and fentanyl citrate. They are marked for over-the-counter use.
- Compared with (the predicate)
- K213040, Nitrile Patient Examination Gloves Blue Tested For Use With Chemotherapy Drugs, Nitrile Patient Examination Gloves Blue
- How it differs
- The summary's comparison table lists differences in color (the predicate includes blue violet), size labels, and some dimensions. The predicate's extra-small and small gloves have a shorter minimum length of 220 mm, compared with 230 mm for the proposed device.
- Testing the summary lists
- Permeation to chemotherapy drugs (ASTM D6978-05, re-approved 2023)
- Permeation to fentanyl citrate injection (ASTM D6978-05, re-approved 2023)
- Dimensions: length, width, and thickness (ASTM D6319-19)
- Tensile strength and elongation before and after aging (ASTM D6319-19)
- Residual powder, less than 2 mg per glove (ASTM D6319-19)
- Freedom from holes, not exceeding 2.5 AQL (ASTM D6319-19)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K261793 took 103 calendar days from receipt to decision. Of the latest 24 other decisions in product code LZA, 14 took longer, 10 were faster; their median was 136 days.
Latest decisions in LZA
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K253508 | Powder Free Nitrite Examination Glove, Cobalt Blue. Violet Blue and White. Non-SterileVietglove Corporation · Traditional | Oct 29, 2026360 days |
| K262208 | Non-sterile, Powder Free Nitrile Examination Aloe Vera Green Gloves, Low Dermatitis Potential, Tested for use with Chemotherapy Drugs, Fentanyl Citrate and Simulated Gastric Acid; Non-sterile, Powder Free Nitrile Examination Gloves, Low Dermatitis Potential, Tested for use with Chemotherapy Drugs, Fentanyl Citrate and Simulated Gastric Acid – Blue; Non-sterile, Powder Free Nitrile Examination Gloves - PinkYty Industry (Manjung) Sdn Bhd · Traditional | Oct 1, 202693 days |
| K261793 | Powder-free Nitrile Examination Gloves Tested for Use With Chemotherapy Drugs and Fentanyl Citrate (Blue and Black Color)Maxter Healthcare, Inc. · Traditional | Sep 9, 2026103 days |
| K262542 | Biodegradable Nitrile Powder Free Examination Glove, Green; Biodegradable Nitrile Powder Free Examination Glove, Violet Blue Tested for Use With 32 Chemotherapy Drugs, Fentanyl & Gastric Acid Permeation Resistance ClaimTop Glove Sdn. Bhd. · Special | Sep 9, 202648 days |
| K260312 | Nitrile Powder Free Examination Glove, Blue Tested for Use with 32 Chemotherapy Drugs and Fentanyl Permeation Resistance Claim; Nitrile Powder Free Examination Glove, Violet Blue Tested for Use with 32 Chemotherapy Drugs, Xylazine, Fentanyl & Gastric AcidGmp Medicare Sdn. Bhd. · Special | Sep 8, 2026221 days |
| K261749 | Cardinal Health Nitrile Blue Examination Gloves Tested for Use with Chemotherapy Drugs and Fentanyl CitrateCardinalhealth · Traditional | Sep 2, 202697 days |
| K260794 | NON-STERILE POWDER FREE NITRILE PATIENT EXAMINATION GLOVES, WITH LICORICE ROOT EXTRACT AND UREA, TESTED FOR USE WITH CHEMOTHERAPY DRUGS, FENTANYL CITRATE, XYLAZINE HCl, AND GASTRIC ACID. OCEAN COLORKossan International Sdn Bhd · Traditional | Aug 18, 2026160 days |
| K262014 | PUREZERO* MARIN* Nitrile Powder-Free Exam Gloves; PUREZERO* MARIN-XTRA* Nitrile Powder-Free Exam GlovesO&M Halyard, Inc. · Special | Jul 21, 202636 days |
| K254285 | Nitrile Powder Free Examination Gloves Tested for Use with Chemotherapy Drugs – Aqua Blue; Nitrile Powder Free Examination Gloves Tested for Use with Chemotherapy Drugs – Violet Blue; Nitrile Powder Free Examination Gloves Tested for Use with Chemotherapy Drugs – Dark Blue; Nitrile Powder Free Examination Gloves Tested for Use with Chemotherapy Drugs – Dark Violet BlueHartalega NGC Sdn. Bhd. · Special | Jul 20, 2026201 days |
| K252117 | Biodegradable Powder Free Nitrile Examination Glove, Blue Color, Tested for use with Chemotherapy drugs, Fentanyl Citrate, Simulated Gastric Acid and Fentanyl Citrate-Simulated Gastric Acid SolutionSw Technologies, Inc. · Special | Jun 24, 2026352 days |
Other 510(k)s from Maxter Healthcare, Inc.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
This is the only 510(k) in openFDA under this applicant name.
Watch LZA in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get LZA every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in LZA. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K261793Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:LZARetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:LZARetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:LZA AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Maxter Healthcare, Inc."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil