FDA device news · Product code DQO

FDA 510(k) clearance

Arterial Pressure Monitoring Set/Tray (K261455): Spectrum Vascular 510(k) clearance

White Plains, NY

Follow DQO: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Jun 26, 2026
Received
May 1, 2026
510(k) type
Traditional
Product code
DQOCatheter, Intravascular, Diagnostic
Review panel
Cardiovascular
Device class
Class II
Regulation
21 CFR 870.1200
Third-party review
No
Summary or statement
Summary
Review time
56 daysreceipt to decision, calendar days
Median in DQO
123 daysthe latest 24 other decisions
DQO decisions
3in the last 12 months
Applicant’s 510(k)s
6in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The Arterial Pressure Monitoring Set/Tray is a sterile, single-use kit made up of a pressure monitoring catheter, a wire guide, an entry access needle, and a syringe. The catheter is inserted into a blood vessel using the Seldinger technique, a common method where a needle and wire guide are used to place a thin tube. Depending on its length, it can reach the radial artery, femoral artery, or distal aorta.
What it’s cleared for
The device is cleared for arterial blood pressure monitoring and blood sampling in adult and pediatric patients. Catheters of 2.5 French are for patients from birth and older, 3.0 and 4.0 French for patients aged 1 year and older, and 5.0 French for patients aged 12 years and older.
Compared with (the predicate)
  • K254278, Arterial Pressure Monitoring Set/Tray
How it differs
The summary says the device is identical to the predicate except for the location and parameters of its ethylene oxide sterilization. It states there are no changes to catheter design or materials.
Testing the summary lists
  • Biocompatibility (no additional testing; predicate testing applied based on the same EtO method at a lower gas concentration)
  • Electrical safety (not applicable; device has no electrical components)
  • Electromagnetic compatibility (not applicable; device has no electrical components)
  • Software (not applicable; device has no software)
  • Ethylene oxide sterilization performance qualification

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K261455 took 56 calendar days from receipt to decision. Of the latest 24 other decisions in product code DQO, 20 took longer, 4 were faster; their median was 123 days.

Latest decisions in DQO

NumberDevice and applicantDecision and review time
K261455 Arterial Pressure Monitoring Set/TraySpectrum Vascular · Traditional Jun 26, 202656 days
K252702 Bioptimal Pulmonary Artery Monitoring Catheter (TD2502NF, TD2502NGF, TD2502NDF, TD2502NCF, TD2502NCGF, TD2502NDGF, TD2502NDCF, TD2502NDCGF, TD2502NXCF, TD2502NDXF, TD2502NXCGF, TD2502NDXGF, TD2502NDXCF, TD2502NDXCGF, TD2502-110NF, TD2502-110NGF, TD2502-110NDF, TD2502-110NCF, TD2502-110NDGF, TD2502-110NDCF, TD2502-110NCGF, TD2502-110NDCGF, TD2502-110NXF, TD2502-110NXGF, TD2502-110NDXF, TD2502-110NXCF, TD2502-110NDXGF, TD2502-110NDXCF ,TD2502-110NXCGF, TD2502-110NDXCGF, TD2602NF, TD2602NBioptimal International Pte. , Ltd. · Traditional May 28, 2026274 days
K254278 Arterial Pressure Monitoring Set/TraySpectrum Vascular · Special Mar 25, 202685 days
K250751 DualView CatheterTerumo Corporation · Traditional Jul 17, 2025127 days
K242966 Gentuity® HF-OCT Imaging System with Vis-Rx Prime® Micro-Imaging CatheterGentuity, LLC · Traditional Jan 31, 2025127 days
K242420 pNOVUS 21 MicrocatheterPhenox, Ltd. · Traditional Nov 12, 202489 days
K233268 Impress Angiographic CatheterMerit Medical Systems, Inc. · Special May 22, 2024236 days
K233975 Zoom 6F Insert CathetersImperative Care, Inc. · Traditional Apr 2, 2024109 days
K232536 Soldier MicrocatheterEmbolx, Inc. · Traditional Feb 23, 2024186 days
K232573 INFINITI™ Ambi Angiographic CatheterCordis US Corp · Traditional Nov 21, 202388 days

Other 510(k)s from Spectrum Vascular

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

NumberDevice and applicantDecision and review time
K260165 Unimpregnated Central Venous CatheterSpectrum Vascular · Traditional Aug 10, 2026202 days
K254278 Arterial Pressure Monitoring Set/TraySpectrum Vascular · Special Mar 25, 202685 days
K252373 BioFlo Hybrid PICC with ENDEXO Technology and PASV Valve Technology; BioFlo PICC with ENDEXO Technology and PASV Valve Technology; BioFlo PICC with ENDEXO Technology; BioFlo Midline Catheter; Xcela Power Injectable PICC; Xcela PICC with PASV Valve Technology; Xcela Hybrid PICC with PASV Valve TechnologySpectrum Vascular · Traditional Dec 16, 2025139 days
K250724 Intraosseous Infusion NeedlesSpectrum Vascular · Traditional Jul 30, 2025142 days
K241115 SV Spectrum MRC Central Venous Catheter; SV Spectrum MR Central Venous Catheter; SV Central Venous CatheterSpectrum Vascular · Traditional Nov 27, 2024218 days

Watch DQO in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get DQO every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in DQO. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.