FDA device news · Product code QJP
FDA 510(k) clearance
PATH BGC (K260938): Crossroads Neurovascular, Inc. 510(k) clearance
Lake Forest, CA
- Decision
- Substantially Equivalent
- Decision date
- Apr 15, 2026
- Received
- Mar 20, 2026
- 510(k) type
- Special
- Product code
- QJPCatheter, Percutaneous, Neurovasculature
- Review panel
- Cardiovascular
- Device class
- Class II
- Regulation
- 21 CFR 870.1250
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 26 daysreceipt to decision, calendar days
- Median in QJP
- 143 daysthe latest 24 other decisions
- QJP decisions
- 24in the last 12 months
- Applicant’s 510(k)s
- 2in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The PATH BGC is a balloon guide catheter, a thin flexible tube that is placed into blood vessels. It has two coaxial lumens (inner channels), reinforced with a coil and a braid, and a compliant balloon near its tip. The balloon can inflate to temporarily block blood flow in a vessel during angiographic procedures, which are imaging procedures that use X-ray and contrast dye.
- What it’s cleared for
- The PATH BGC is cleared to help insert and guide an intravascular catheter into a selected blood vessel in the neurovascular system, which is the blood vessels of the brain, spine and head and neck. The balloon provides temporary vascular occlusion (temporary blocking of blood flow) during these and other angiographic procedures. The summary does not state a specific patient group.
- Compared with (the predicate)
- K242392, PATH BGC Balloon Guide Catheter
- Testing the summary lists
- Liquid leak, air leak, static and dynamic burst, and corrosion resistance (ISO 10555-1)
- Hub and connector compatibility (ISO 80369-7)
- Particulate count in a simulated anatomy model, which the summary reports as passing acceptance criteria
- Packaging tests (ASTM F2096-11 bubble leak, ASTM F88 pouch seal strength), shelf life, transit testing and sterility
- Animal, sterilization and shelf life, biocompatibility and clinical studies were stated as not deemed necessary
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K260938 took 26 calendar days from receipt to decision. Of the latest 24 other decisions in product code QJP, 23 took longer, 1 took the same time; their median was 143 days.
Latest decisions in QJP
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K261449 | NeuroSheathPerfuze, Ltd. · Traditional | Nov 5, 2026188 days |
| K261649 | Excelsior Reach MicrocatheterStryker Neurovascular · Traditional | Oct 9, 2026143 days |
| K261938 | APRO 88 CatheterAlembic, LLC · Traditional | Oct 6, 2026118 days |
| K253422 | OAB Delivery CatheterCognition Medical Corp. · Traditional | Oct 2, 2026366 days |
| K260220 | Route 92 Medical Full Length 046 Access SystemRoute 92 Medical, Inc. · Traditional | Sep 16, 2026233 days |
| K262277 | 70 NeuGlide CatheterPiraeus Medical, Inc. · Special | Sep 4, 202660 days |
| K261176 | Zoom 4S CatheterImperative Care, Inc. · Traditional | Aug 28, 2026140 days |
| K254071 | p17 XR MicrocatheterWallaby Medical · Traditional | Aug 18, 2026243 days |
| K260199 | SLIM MicrocatheterBalt USA, LLC · Traditional | Jul 13, 2026172 days |
| K253901 | Millipede88 Access CatheterPerfuze, Ltd. · Traditional | Jul 9, 2026216 days |
Other 510(k)s from Crossroads Neurovascular, Inc.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K242392 | PATH BGCCrossroads Neurovascular, Inc. · Traditional | May 9, 2025270 days |
Watch QJP in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get QJP every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in QJP. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K260938Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:QJPRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:QJPRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:QJP AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Crossroads Neurovascular, Inc."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil