FDA device news · Product code SDD

FDA 510(k) clearance

Dexter L6 System (K260653): Distalmotion SA 510(k) clearance

Epalinges, CH

Follow SDD: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Jun 11, 2026
Received
Feb 27, 2026
510(k) type
Traditional
Product code
SDDElectromechanical Surgical System Wherein The Surgeon Annd The User Interface Can Be In The Sterile Field
Review panel
General, Plastic Surgery
Device class
Class II
Regulation
21 CFR 878.4965
Third-party review
No
Summary or statement
Summary
Review time
104 daysreceipt to decision, calendar days
Median in SDD
135 daysthe latest 4 other decisions
SDD decisions
2in the last 12 months
Applicant’s 510(k)s
5in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The Dexter L6 System is a robotic surgical system used to help surgeons perform minimally invasive (keyhole) surgery. The surgeon controls instruments and an endoscope camera from a surgeon console, while two patient carts positioned at the operating table hold and move the instruments inserted into the patient.
What it’s cleared for
The system is cleared to assist in accurate control of endoscopes and endoscopic instruments for grasping, suturing, dissecting, coagulating and cutting tissue. It is indicated for laparoscopic inguinal hernia repair, cholecystectomy, total benign hysterectomy including salpingo-oophorectomy, and sacrocolpopexy, for adults aged 22 and older, used by trained laparoscopic or robotic surgeons in an operating room. It is prescription use only.
Compared with (the predicate)
How it differs
The summary says the device has the same technological characteristics as its predicate. The main change is updated labeling that adds the sacrocolpopexy procedure to the indications for use. The summary states there have been no other changes to the device since the predicate clearance.
Testing the summary lists
  • Extensive bench testing on the previously cleared Dexter L6 System, which the summary says remains applicable

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K260653 took 104 calendar days from receipt to decision. Of the latest 4 other decisions in product code SDD, 2 took longer, 1 was faster, 1 took the same time; their median was 135 days.

Latest decisions in SDD

NumberDevice and applicantDecision and review time
K261398 Dexter L6 SystemDistalmotion SA · Traditional Aug 11, 2026104 days
K260653 Dexter L6 SystemDistalmotion SA · Traditional Jun 11, 2026104 days
K251197 Dexter L6 SystemDistalmotion SA · Traditional Sep 30, 2025166 days
K250435 Dexter L6 SystemDistalmotion SA · Traditional May 27, 2025102 days
DEN230084 Dexter L6 SystemDistalmotion SA · Direct Oct 25, 2024315 days

Other 510(k)s from Distalmotion SA

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

NumberDevice and applicantDecision and review time
K261398 Dexter L6 SystemDistalmotion SA · Traditional Aug 11, 2026104 days
K251197 Dexter L6 SystemDistalmotion SA · Traditional Sep 30, 2025166 days
K250435 Dexter L6 SystemDistalmotion SA · Traditional May 27, 2025102 days
DEN230084 Dexter L6 SystemDistalmotion SA · Direct Oct 25, 2024315 days

Watch SDD in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get SDD every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in SDD. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.