FDA device news · Product code QXO

FDA 510(k) clearance

EchoNext (K260332): Pathwai, Inc. 510(k) clearance

New York, NY

Follow QXO: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Jun 8, 2026
Received
Feb 2, 2026
510(k) type
Traditional
Product code
QXOCardiovascular Machine Learning-Based Notification Software
Review panel
Cardiovascular
Device class
Class II
Regulation
21 CFR 870.2380
Third-party review
No
Summary or statement
Summary
Review time
126 daysreceipt to decision, calendar days
Median in QXO
205 daysthe latest 1 other decisions
QXO decisions
1in the last 12 months
Applicant’s 510(k)s
1in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
EchoNext is software (software-as-a-medical-device) that analyzes a standard resting 12-lead electrocardiogram (ECG), the common heart tracing recorded from electrodes on the body. It uses a deep neural network, a type of machine-learning model, to look for subtle electrical patterns that may point to structural heart disease, meaning abnormalities of the heart's chambers, walls, or valves.
What it’s cleared for
EchoNext is cleared to analyze 12-lead ECG recordings from patients 18 years of age or older, in parallel with the standard of care, to identify patients who may need further structural heart disease follow-up. It is not for patients with implanted pacemakers. The summary says it is not to be used in place of full patient evaluation, and its results are not meant to rule out follow-up.
Compared with (the predicate)
  • DEN230003, Viz HCM
How it differs
The summary says EchoNext covers structural heart disease and six sub-labels, while the predicate Viz HCM detects hypertrophic cardiomyopathy (HCM) only. EchoNext also has a built-in view of the ECG and analysis results, which the predicate does not. The summary says the two devices share the same input, output type, and patient population.
Testing the summary lists
  • Software verification and validation (unit, integration, and system-level testing; 101 of 101 test cases passed)
  • Cybersecurity (static and dynamic code analysis, fuzz testing, and penetration testing; no vulnerabilities identified)
  • Human factors validation (15 participants; zero use errors or close calls)

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K260332 took 126 calendar days from receipt to decision. Of the latest 1 other decision in product code QXO, 1 took longer; their median was 205 days.

Latest decisions in QXO

NumberDevice and applicantDecision and review time
K260332 EchoNextPathwai, Inc. · Traditional Jun 8, 2026126 days
DEN230003 Viz HCMViz. Ai, Inc. · Direct Aug 3, 2023205 days

Other 510(k)s from Pathwai, Inc.

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

This is the only 510(k) in openFDA under this applicant name.

Watch QXO in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get QXO every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in QXO. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.