FDA device news · Product code HRX

FDA 510(k) clearance

TruVision Single-Use 1.9mm Arthroscopy System (K260156): Nexus CMF, LLC 510(k) clearance

Salt Lake City, UT

Follow HRX: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Oct 9, 2026
Received
Jan 20, 2026
510(k) type
Traditional
Product code
HRXArthroscope
Review panel
Orthopedic
Device class
Class II
Regulation
21 CFR 888.1100
Third-party review
No
Summary or statement
Summary
Review time
262 daysreceipt to decision, calendar days
Median in HRX
157 daysthe latest 24 other decisions
HRX decisions
9in the last 12 months
Applicant’s 510(k)s
1in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The TruVision Single-Use 1.9mm Arthroscopy System is a rigid arthroscope, a thin scope inserted into a joint, paired with a reusable Camera Control Unit. The arthroscope is a sterile, single-use 1.9 mm device with a tiny camera chip at its tip (chip-on-tip CMOS imaging) and LED lights. The Camera Control Unit processes the video signal and sends live images to an external display through HDMI ports.
What it’s cleared for
The device is cleared for diagnostic and operative arthroscopic procedures, where it provides light and visualization of the joint through a natural or surgical opening.
Compared with (the predicate)
  • K212556, Trice Medical mi-eye 3 with cannula, mi-tablet 3
Testing the summary lists
  • Sterilization (ISO 11135, AAMI TIR 28, ISO 10993-7)
  • Packaging and shelf life (ISO 11607-1, ASTM D4169, ASTM F1980, ASTM F1886, ASTM F2096, ASTM F88)
  • Biocompatibility (ISO 10993-1, -5, -10, -11)
  • Software and cybersecurity (firmware verification testing)
  • Electrical safety and EMC (IEC 60601-1, IEC 60601-2-18, IEC 60601-1-2)
  • Performance bench testing (optical, mechanical, environmental, simulated use and user validation per IEC 62366-1)

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K260156 took 262 calendar days from receipt to decision. Of the latest 24 other decisions in product code HRX, 5 took longer, 19 were faster; their median was 157 days.

Latest decisions in HRX

NumberDevice and applicantDecision and review time
K263208 Vantage Lumbar Decompression KitSurGenTec, LLC · Special Oct 14, 202630 days
K260156 TruVision Single-Use 1.9mm Arthroscopy SystemNexus CMF, LLC · Traditional Oct 9, 2026262 days
K260203 Fule Vertebroplasty Balloon CatheterBeijing Fule Science & Technology Development Co., Ltd. · Traditional Aug 28, 2026217 days
K254103 HOPKINS Telescopes for ArthroscopyKarl Storz SE & CO. KG · Traditional Aug 26, 2026250 days
K252790 Digital ClarusScope System and Digital NeuroPEN SystemClarus Medical, LLC · Traditional May 26, 2026266 days
K253523 Freedom DS™ Decompression SystemSpinal Simplicity · Traditional Apr 16, 2026154 days
K252546 VantageTM Lumbar Decompression KitAllevion Medical, LLC · Traditional Mar 12, 2026212 days
K253217 MiiS Horus Arthroscope (EJA 100); MiiS Horus Endoscope Display System -Tablet (EDS 500); MiiS Horus Endoscope Display System -Video Box (EVS 700)Medimaging Integrated Solution, Inc (Miis) · Traditional Dec 23, 202585 days
K250795 PUREVUE™ FMSW.O.M. World of Medicine GmbH · Traditional Dec 5, 2025266 days
K252666 Articulator Arthroscopic BurJoint Preservation Innovations, LLC · Traditional Nov 21, 202588 days

Other 510(k)s from Nexus CMF, LLC

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

This is the only 510(k) in openFDA under this applicant name.

Watch HRX in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get HRX every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in HRX. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.