FDA device news · Product code LLZ
FDA 510(k) clearance
CMN Capillary Function with Virtual Expert for MRI, CT and CBCT (K253831): Cercare Medical A/S 510(k) clearance
Aarhus C, DK
- Decision
- Substantially Equivalent
- Decision date
- May 18, 2026
- Received
- Dec 1, 2025
- 510(k) type
- Traditional
- Product code
- LLZSystem, Image Processing, Radiological
- Review panel
- Radiology
- Device class
- Class II
- Regulation
- 21 CFR 892.2050
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 168 daysreceipt to decision, calendar days
- Median in LLZ
- 107 daysthe latest 25 other decisions
- LLZ decisions
- 50in the last 12 months
- Applicant’s 510(k)s
- 4in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- Cercare Medical Neurosuite (CMN) Capillary Function with Virtual Expert is a software-only image processing package for viewing and analyzing brain scans from MRI, CT and cone-beam CT (CBCT, a CT-type scanner). It runs on standard computers and processes DICOM, the standard digital format for medical images.
- What it’s cleared for
- The software is cleared for trained professionals, including physicians and medical technicians, to view, process and analyze MRI, CT and CBCT images. For MRI and CT, one clinical application is to visualize blood perfusion and to calculate threshold volumes and a mismatch ratio in brain tissue affected by acute stroke. The summary describes the software as decision support only, with clinicians making all treatment decisions.
- Compared with (the predicate)
- K241989, CMN Capillary Function with Virtual Expert for MRI and CT
- How it differs
- The device adds CBCT perfusion post-processing and CBCT-based detection of stroke lesions. The summary says the perfusion algorithms cleared for CT are reused for CBCT data, with extra steps to align image intensity and timing. The summary says the differences do not change the intended use. Its MR and CT capabilities are the same as the predicate.
- Testing the summary lists
- Software verification and validation testing
- Virtual Expert comparison testing on retrospective CT perfusion patient data
- DICOM conformance (NEMA PS 3.1-3.20)
- Cybersecurity and software lifecycle documentation under FDA guidance and IEC 62304
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K253831 took 168 calendar days from receipt to decision. Of the latest 25 other decisions in product code LLZ, 3 took longer, 22 were faster; their median was 107 days.
Latest decisions in LLZ
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262132 | 3D Anatomical ModelThe Jacobs Institute · Traditional | Nov 5, 2026134 days |
| K260454 | LiLi DICOM Viewer (LiLi )Elevate Imaging, Inc. · Traditional | Nov 4, 2026266 days |
| K263648 | Vitrea Advanced Visualization, Version 7.16Canon Medical Informatics, Inc. · Special | Oct 29, 202627 days |
| K261763 | MIM – KineticIDMim Software, Inc. · Traditional | Oct 26, 2026151 days |
| K261531 | PV-iCurve ProPerception Vision Medical Technology Co., Ltd. · Traditional | Oct 21, 2026166 days |
| K261788 | Eden PACSHigia., Inc. d/b/a Eden · Abbreviated | Oct 21, 2026145 days |
| K263048 | Syngo Carbon Space (VA4)Siemens Healthineers AG · Traditional | Sep 29, 202629 days |
| K261874 | Syneris PACS v.1.0.1.0Syneris · Traditional | Sep 23, 2026110 days |
| K262442 | HipStudio AnalysisReplasia BV · Traditional | Sep 22, 202668 days |
| K261855 | Elucid PlaqueIQElucid Bioimaging, Inc. · Traditional | Sep 18, 2026107 days |
Other 510(k)s from Cercare Medical A/S
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K260316 | CMN Capillary Function with Oncology Virtual ExpertCercare Medical A/S · Traditional | Jun 22, 2026143 days |
| K241989 | Cercare Medical Neurosuite (CMN) Capillary Function with Virtual ExpertCercare Medical A/S · Traditional | Dec 6, 2024151 days |
| K230016 | Cercare Medical NeurosuiteCercare Medical A/S · Traditional | Jul 14, 2023192 days |
Watch LLZ in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get LLZ every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in LLZ. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K253831Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:LLZRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:LLZRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:LLZ AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Cercare Medical A/S"Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil